ChipFind - документация

Электронный компонент: LTD104C11S

Скачать:  PDF   ZIP
(1/
9) 2003-11-27 (Ver.0.4R)



PRODUCT INFORMATION
FEATURES:
(1)10.4" VGA color display with High Luminance (400cd/m
2
)
(2)Wide Viewing Angle (Vertical:120, Horizontal:140)
(3)Built in Long Life Lamps (50,000 h)
MECHANICAL SPECIFICATIONS
Item
Specifications
Dimensional Outline (typ.)
238.5(
W) x 177.5(H) x 12max(D) mm
Number of Pixels
640(
W) x 480(H) pixels
Active Area
211.2(
W) x 158.4(H) mm
Pixel Pitch
0.33(
W) x 0.33(H)
Weight (approximately)
500g
Backlight
Twin CCFLs, Sidelight type
ABSOLUTE MAXIMUM RATINGS
Item
Min.
Max.
Unit
(
V
DD
)
-0.3
6.5
V
Supply Voltage
(
V
FL
)
0
2.0
kV(rms)
FL Driving Frequency (
f
FL
)
---
100
kHz
Input Signal Voltage (
V
IN
)
-0.3
V
DD
+0.3
V
Operating Temperature (Note
-10
65
C
Storage Temperature
-20
80
C
Storage Humidity
(Max. wet bulb temperature = 39
C)
10
90
%(RH)
Note) Only operation is guarantied at Operating Temperature. Display quality is evaluated at +25
C.
ELECTRICAL SPECIFICATION (Ta=25
C) (RECOMMENDED OPERATION CONDITION)
Item
Min.
Typ.
Max.
Unit
Remarks
4.75
5.0
5.25
V
V
DD
:5V
(
V
DD
)
3.0
3.3
3.6
V
V
DD
:3.3V
Supply Voltage
(
V
FL
)
---
460
---
V(rms)
FL Start Voltage
1200
---
1900
V(rms)
Ta=-10
C
High Level Input Voltage (
V
IH
)
0.7 V
DD
---
V
DD
Low Level Input Voltage (
V
IL
)
0
---
0.3 V
DD
V
*
1
(
I
DD
)
---
225
---
mA
Current Consumption
*
2
(
I
FL
)
3.0
6.0
6.5
mA(rms)
*1 *2
Power Consumption
---
6.3
---
W
I
FL
=6.0mA(rms)
V
DD
:3.3V
*1 : 8 color bars pattern
*2 : Except the efficiency of FL inverter
OPTICAL SPECIFICATION (Ta=25
C)
Item
Min.
Typ.
Max.
Unit
Remarks
Contrast Ratio (
CR)
250
500
---
---
(Upper+Lower)
---
120
---
Viewing Angle
(
CR
10)
(Left+Right)
---
140
---
(
r
)
---
---
50
ms
Response Time
(
f
)
---
---
50
ms
Luminance
---
400
---
cd/m
2
I
FL
=6.0mA(rms)
Lamp Life Time (MTBF)*
3
*
4
50,000
h
*3 : Conditions ;
Ta=25
C,
I
FL
=6.0mA(rms), continuous lighting
*4 : Definitions of failure ; 1) Lcd luminance becomes half of the minimum value. 2) Lamp doesn't light normally.
*The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by
Toshiba Matsushita Display Technology or other rights of the third parties which may result from its use. No license is granted by
implication or otherwise under any patent or patent rights of Toshiba Matsushita Display Technology or others.

*The information contained herein may be changed without prior notice. It is therefore advisable to contact Toshiba Matsushita Display
Technology before proceeding with the design of equipment incorporating this product.
26cm COLOUR TFT-LCD MODULE
(10.4 TYPE)
LTD104C11S
(a-Si TFT)
TENTATIVE
Toshiba Matsushita Display Technology Co., Ltd
All information is subject to change without notice. Please read bottom notes.
(2/
9) 2003-11-27 (Ver.0.4R)
LTD104C11S

DIMENSIONAL OUTLINE
TENTATIVE
Unit : mm
Standard tolerance :
0.5
4
4
4
(6
6.
3)
4
(
D
F
1
4
H
-
2
P
-
1
.
2
5
H
,
D
F
1
4
H
-
3
0
P
-
1
.
2
5
H
)
2
1
3
.
2
(
V
i
e
w
i
n
g
A
r
e
a
)
9.
5
4
2
9.
5
4
3
.
8
8
.
7
4
8
4
7
9
4
7
8
14
.6
13
2.
6
16
1.
8(
Be
ze
l
Op
en
in
g)
17
7.
5
(1
57
.1
)
20
.4
15
8.
4(
Ac
ti
ve
Ar
ea
)
2
3
8
.
5
(
2
3
4
.
7
)
2
3
0
.
9
2
1
4
.
6
(
B
e
z
e
l
O
p
e
n
i
n
g
)
(
1
1
6
)
37
.5
1
1
.
5
2
.
5
2
.
5
1
0
0
16
0.
4(
Vi
ew
in
g
Ar
ea
)
T
E
N
T
A
T
I
V
E
3
.
5
3
.
5
3
.
5
3
.
5
+
1
0
+
1
+
1
+1
I
/
F
C
o
n
n
e
c
t
o
r
(
R
e
a
r
S
i
d
e
)
2
1
1
.
2
(
A
c
t
i
v
e
A
r
e
a
)
(3/
9) 2003-11-27 (Ver.0.4R)
LTD104C11S

BLOCK DIAGRAM




SEQUENCE OF POWER SUPPLIES AND SIGNALS













(4/
9) 2003-11-27 (Ver.0.4R)
LTD104C11S

TIMING CHART


tv
tvw
VSYNC
th
HSYNC
tv,
p
tvds
tvde
tvblnk
DE
479
480
1
2
th
thw
HSYNC
thfp
thds
thde
DE
640
RGB data
NCLK
1 2 3 4 5
(5/
9) 2003-11-27 (Ver.0.4R)
LTD104C11S

TIMING SPECIFICATION
1) 2) 3) 4) 5) 6)
Item
Symbol
min.
typ.
Max.
unit
Frame Period
tv
500
525
550
th
Vertical blanking Term
tvblnk
20
45
70
th
V-sync Pulse Width
tvw
2
-
-
th
Vertical Front Porch
tvfp
2
-
-
th
Vertical Data Sync Period
tvds
6
-
-
th
Vertical Display Term
tvde
480
480
480
th
Horizontal Period
th
740
800
860
tc
H-sync Pulse Width
thw
8
160
-
tc
Horizontal Front Porch
thfp
8
-
-
tc
Horizontal Data Sync Period
thds
8
-
-
tc
Horizontal Display Term
thde
640
640
640
tc
Clock Period
tc
35.0
39.7
-
ns
Clock "H" Time
tch
10.0
-
-
ns
Clock "L" Time
tcl
10.0
-
-
ns
Data Setup Time
tds
5.0
-
-
ns
Data Hold Time
tdh
10.0
-
-
ns
Note 1) If NCLK is fixed to "H" or "L" level for certain period while DE is supplied, the panel may be damaged.

Note 2) Please adjust LCD operating signal timing and FL driving frequency, to optimize the display quality.
There is a possibility that flicker is observed by the interference of LCD operating signal timing and FL driving condition
(especially driving frequency), even if the condition satisfies above timing specifications and recommended operating
conditions shown in 3.

Note3 ) Do not make
tv, th and tvds fluctuate.
Note4) In case of using the long frame period, the deterioration of display quality, noise etc. may be occurred.
Note5) NCLK count of each Horizontal Scanning Time should be always the same.
V-Blanking period should be "
n" X "Horizontal Scanning Time". (n: integer)
Frame period should be always the same.
(6/
9) 2003-11-27 (Ver.0.4R)
LTD104C11S

CONNECTOR PIN ASSIGNMENT FOR INTERFACE
CN1 INPUT SIGNAL
Connector : DF14H-30P-1.25H / HIROSE ELECTRIC CO., LTD.
Mating Connector : DF14-30S-1.25C, Contact Pin : DF14-2628SCF
Terminal No.
Symbol Function
1
GND
2
NCLK
SAMPLING CLOCK
3
H-Sync
HORIZONTAL SYNC.
4
V-Sync
VERTICAL SYNC.
5
GND
6
R0
2)
RED DISPLAY DATA (LSB)
7
R1
2)
RED DISPLAY DATA
8
R2
2)
RED DISPLAY DATA
9
R3
2)
RED DISPLAY DATA
10
R4
2)
RED DISPLAY DATA
11
R5
2)
RED DISPLAY DATA (MSB)
12
GND
13
G0
2)
GREEN DISPLAY DATA (LSB)
14
G1
2)
GREEN DISPLAY DATA
15
G2
2)
GREEN DISPLAY DATA
16
G3
2)
GREEN DISPLAY DATA
17
G4
2)
GREEN DISPLAY DATA
18
G5
2)
GREEN DISPLAY DATA (MSB)
19
GND
20
B0
2)
BLUE DISPLAY DATA (LSB)
21
B1
2)
BLUE DISPLAY DATA
22
B2
2)
BLUE DISPLAY DATA
23
B3
2)
BLUE DISPLAY DATA
24
B4
2)
BLUE DISPLAY DATA
25
B5
2)
BLUE DISPLAY DATA (MSB)
26
DE
DATA ENABLE
27
GND
28
VDD
+3.3V (+5.0V)POWER SUPPLY
29
VDD
+3.3V (+5.0V)POWER SUPPLY
30
GND
CN2 INPUT SIGNAL
Connector : DF14H-2P-1.25H / HIROSE ELECTRIC CO., LTD.
Mating Connector : DF14-2S-1.25C, Contact Pin : DF14-2628SCF
Terminal No.
Symbol Function
1
U D
VERTICAL REVERSE("L" level or Open ; normal, "H" level ; reverse)
2
R L
HORIZONTAL REVERSE ("L" level or Open ; normal , "H" level ; reverse)
CN3 / 4 CCFL POWER SOURCE
Connector : BHR-04VS-1 / JAPAN SOLDERLESS TERMINAL MFG CO., LTD.
Mating Connector
3)
: SM04(4.0)B-BHS-1 / JAPAN SOLDERLESS TERMINAL MFG CO., LTD.
Terminal No.
Symbol Function
1
V
FLH1
CCFL Power Supply ( high voltage)
2
V
FLH2
CCFL Power Supply ( high voltage)
3
NC
1)
Non Connection (open)
4
V
FLL
CCFL Power Supply (low voltage)
Note 1) NC terminal should be open.
Note 2) See next page.
Note 3) Take away terminal No.3 of the mating connector. If does not take away, it may cause smoke burn of
electrical parts by high voltage.
(7/
9) 2003-11-27 (Ver.0.4R)
LTD104C11S

256k (k=1024) COLORS COMBINATION TABLE
Display
R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0
Gray Scale
Level
Black
L L L L L L L L L L L L L L L L L L
-
Blue
L L L L L L L L L L L L H H H H H H
-
Green
L L L L L L H H H H H H L L L L L L
-
Light Blue
L L L L L L H H H H H H H H H H H H
-
Red
H H H H H H L L L L L L L L L L L L
-
Purple
H H H H H H L L L L L L H H H H H H
-
Yellow
H H H H H H H H H H H H L L L L L L
-
Basic
Color
White
H H H H H H H H H H H H H H H H H H
-
Black
L L L L L L L L L L L L L L L L L L
L 0
L L L L L H L L L L L L L L L L L L
L 1
L L L L H L L L L L L L L L L L L L
L 2
:
:
:
:
:
:
L3
...
L60
H H H H L H L L L L L L L L L L L L
L61
Dark
Light
H H H H H L L L L L L L L L L L L L
L62
Gray
Scale of
Red
Red
H H H H H H L L L L L L L L L L L L
Red L63
Black
L L L L L L L L L L L L L L L L L L
L 0
L L L L L L L L L L L H L L L L L L
L 1
L L L L L L L L L L H L L L L L L L
L 2
:
:
:
:
:
:
L3
...
L60
L L L L L L H H H H L H L L L L L L
L61
Dark
Light
L L L L L L H H H H H L L L L L L L
L62
Gray
Scale of
Green
Green
L L L L L L H H H H H H L L L L L L
Green L63
Black
L L L L L L L L L L L L L L L L L L
L 0
L L L L L L L L L L L L L L L L L H
L 1
L L L L L L L L L L L L L L L L H L
L 2
:
:
:
:
:
:
L3
...
L60
L L L L L L L L L L L L H H H H L H
L61
Dark
Light
L L L L L L L L L L L L H H H H H L
L62
Gray
Scale of
Blue
Blue
L L L L L L L L L L L L H H H H H H
Blue L63
Black
L L L L L L L L L L L L L L L L L L
L 0
L L L L L H L L L L L H L L L L L H
L 1
L L L L H L L L L L H L L L L L H L
L 2
:
:
:
:
:
:
L3
...
L60
H H H H L H H H H H L H H H H H L H
L61
Dark
Light
H H H H H L H H H H H L H H H H H L
L62
Gray
Scale of
White &
Black
White
H H H H H H H H H H H H H H H H H H
White L63
(8/
9) 2003-11-27 (Ver.0.4R)
LTD104C11S
RELIABILITY TEST
TEST CONDITIONS
1) The module should be driven and inspected under normal test conditions.
2) The module should not have condensation of water (moisture) on the module.
3) The module should be inspected after two or more hours storage in normal conditions (15 - 35
C,45 - 65%(RH)).
4) A module shall be used only for one test.
SPECIFICATIONS
The module shall have no failure in the following reliability test items.
Test Item
Test Conditions
Result
High Temperature Operation
1)
65
C 192 h
OK
High Temperature Storage
2)
80
C 192 h
OK
High Temperature
High Humidity operation
1)
50
C 80% 192 h
OK
Low Temperature Operation
1)
-10
C 192 h
OK
Low Temperature Storage
2)
-20
C 192 h
OK
Temperature Shock
2)
-20
C
80
C
0.5h 0.5h
50 cycles
OK
Mechanical Vibration
2)
10 - 200 - 10Hz sweep/cycle,
1.5
9.8m/s
2
constant,
X.Y.Z each directions, 0.5h each
OK
Mechanical Shock
2)
50
9.8m/s
2
, 20ms,
X,
Y,
Z direction,
one time each
OK
Note 1) Operating
Note 2) Non-Operating
Definitions of failure for judgment shall be as follows:
1) Function of the module should be maintained.
2) Current consumption should be smaller than the specified value.
3) Appearance and display quality should not have distinguished degradation.
4) Luminance should be larger than 50% of the minimum value specified in OPTICAL SPECIFICATION.




(9/
9) 2003-11-27 (Ver.0.4R)
LTD104C11S
FOR SAFETY
LCD module is generally designed with precise parts to achieve light weighted thin mechanical dimensions.
In using our Modules, make certain that you fully understand and put into practice the warnings and safety precautions detailed
in Engineering Information No.EE-N001,"CAUTIONS AND INSTRUCTIONS FOR TOSHIBA LCD MODULES".
Refer to individual specifications and TECHNICAL DATA sheets (hereinafter called "TD") for more detailed technical
information.

1) SPECIAL PURPOSES
A) Toshiba Matsushita Display Technology's Standard LCD Modules have not been customized for operation in extreme
environments or for use in applications where performance failures could be life-threatening or otherwise catastrophic.

B) Since Toshiba Matsushita Display Technology's Standard LCD Modules have not been designed for operation in extreme
environments, they must never be used in devices that will be exposed to abnormally high levels of vibration or shock which
exceed Toshiba Matsushita Display Technology's published specification limits.
C) In addition, since Toshiba Matsushita Display Technology Standard LCD Modules have not been designed for use in
applications where performance failures could be life-threatening or catastrophic, they must never be installed in aircraft
navigation control systems (such as, but not limited to Traffic Collision Avoidance System and Air Traffic Indicator), in military
defense or weapons systems, in critical industrial process-control systems (e.g., those involved in the production of nuclear
energy), or in critical medical device or patient life-support systems.
2) DISASSEMBLING OR MODIFICATION
DO NOT DISASSEMBLE OR MODIFY the module. It may damage sensitive parts inside LCD module, and may cause
scratches or dust on the display.
Toshiba Matsushita Display Technology doses not warrant the module, if customer disassembled or modified it.
3) BREAKAGE OF LCD PANEL
DO NOT INGEST liquid crystal material, DO NOT INHALE this material, and DO NOT CONTACT the material with skin, if LCD
panel is broken and liquid crystal material spills out.
If liquid crystal material comes into mouth or eyes, rinse mouth or eyes out with water immediately.
If this material contact with skin or cloths, wash it off immediately with alcohol and rinse thoroughly with water.
4) GLASS OF LCD PANEL
BE CAREFUL WITH CHIPS OF GLASS that may cause injuring fingers or skin, when the glass is broken.
5) ELECTRIC SHOCK
DISCONNECT POWER SUPPLY before handling LCD module.
DO NOT TOUCH the parts inside LCD module and the fluorescent lamp's connector or cables in order to prevent electric
shock, because high voltage is supplied to these parts from the inverter unit while power supply is turned on.
6) ABSOLUTE MAXIMUM RATINGS AND POWER PROTECTION CIRCUIT
DO NOT EXCEED the absolute maximum rating values under the worst probable conditions caused by the supply voltage
variation, input voltage variation, variation in parts' constants, environmental temperature, etc., otherwise LCD module may be
damaged.
Employ protection circuit for power supply, whenever the specification or TD specifies it.
Suitable protection circuit should be applied for each system design.
7) RECOMMENDED OPERATION CONDITIONS
The performance and quality of the LCD panel are warranted only when the LCD panel is used within "the recommended
operation conditions". Toshiba Matsushita Display Technology Co., Ltd. never warrants the performance and quality of the
LCD panel when you use the LCD panel over "the recommended operation conditions", although within "the absolute
maximum rating".
To use the LCD panel over "the recommended operation conditions" may have bad influence on the characteristics and
reliability of the LCD panel and may shorten the life of the LCD panel.
Therefore, when designing the whole set, not to be over "the recommended operation conditions", you should fully take care of
supply voltage change, characteristic of connection parts, serge of input-and-output line, and surrounding temperature.
8)
DISPOSAL
When dispose LCD module, obey to the applicable environmental regulations.
!