ChipFind - документация

Электронный компонент: D60

Скачать:  PDF   ZIP
.
LOW COST, HIGH RELIABILITY
.
COMPACT SIZE, LIGHT WEIGHT
.
105
C OUTPUT CAPACITOR
.
100% FULL LOAD BURN-IN TEST
.
INTERNATIONAL AC INPUT RANGE
.
BUILT IN EMI FILTER, LOW RIPPLE NOISE
.
HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.
SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.
SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED
MODEL
SPECIFICATION
D-60A
D-60B
CH1
CH2
CH1
CH2
DC OUTPUT VOLTAGE
5V
12V
5V
24V
OUTPUT V. TOLERANCE
2%
6%
2%
5%
OUTPUT RATED CURRENT
4A
3A
3A
1.8A
OUTPUT CURRENT RANGE
0.3-6A
0.2-4A
0.3-6A
0.2-2.2A
RIPPLE & NOISE
75mVp-p
150mVp-p
75mVp-p
150mVp-p
LINE REGULATION
0.5%
1%
0.5%
0.5%
LOAD REGULATION
0.5%
4%
0.5%
4%
DC OUTPUT POWER
56W
58W
EFFICIENCY
73%
76%
DC VOLTAGE ADJ.
CH1:+10,-5%
CH1:+10,-5%
INPUT VOLTAGE RANGE
85~264VAC 47~63Hz; 120~370VDC
AC CURRENT
2A/115V 1A/230V
INRUSH CURRENT
COLD START 30A/115V 60A/230V
LEAKAGE CURRENT
<1mA/240VAC
OVERLOAD PROTECTION
105%~150% TYPE:PULSING HICCUP SHUTDOWN RESET:AUTO RECOVERY
OVER VOLTAGE PROTECTION
CH1:5.75~6.75V
OVER TEMP. PROTECTION
----------
TEMP. COEFFICIENT
0.03% /
C (0~50
C) ON +5V OUTPUT
SETUP, RISE, HOLD UP TIME
800ms, 50ms, 10ms / 115VAC 300ms, 50ms, 80ms / 230VAC
VIBRATION
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
WORKING TEMP., HUMIDITY
-10
C~+60
C(REFER TO OUTPUT DERATING CURVE), 20%~90% RH
STORAGE TEMP., HUMIDITY
-20
C~+85
C, 10%~95% RH
DIMENSION
159*97*38mm CASE:901
WEIGHT
0.55Kgs
SAFETY STANDARDS
UL1012, TUV EN60950, IEC950, UL1950 APPROVED
EMC STANDARDS
CISPR22 (EN55022) CLASS B, IEC801-2,3,4, IEC555-2 VERIFICATION
NOTE :
1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25
C
70% RH. AMBIENT.
2.TOLERANCE GINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD.
6.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER.
7.C2,3,6 MUST BE REMOVED.
2000-10-03
TOTAL POWER INT.
D60 AC-DC 60W POWER SUPPLY WITH DUAL OUTPUT