ChipFind - документация

Электронный компонент: MBU115

Скачать:  PDF   ZIP
Key Features
l
SMT Technology
l
Miniture Package
l
I / O Isolation 1000VDC
l
Efficiency Up To 80%
l
MTBF > 2,000,000 Hours
l
Low Cost
Mechanical Configuration
0.45 (11.5)
0.02
(0.5)
0.02
(0.5)
0.10
(2.54)
0.40
(10.2)
0.126
(3.2)
0.07
(1.80)
0.01
(0.25)
T
1
2
4
All dimensions typical in inches (mm). Tolerance= +/- 0.01 (+/- 0.25)
3
+Vo
Bipolar
Push-Pull
Inverter
+Vin
-Vin
-Vo
+Output
4
-Output
3
+Input
2
-Input
1
Function
Pin
Pin Connections
1.3g( 5 & 12V Input )
1.7g( 24V Input )
Weight
Non-Conductive Black Plastic
Case Material
11.5*7.1*10.2 mm
0.45*0.28*0.40 inches
Case Size
( 24V Input)
11.5*6.1*10.2 mm
0.45*0.24*0.40 inches
Case Size
( 5 & 12V Input)
Physical Characteristics
TOTAL POWER INT'L
MBU100 Series 1Watt Ultra Miniature High SIP DC/DC Converters
with
Single Output
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-1-
mW
450
---
Internal Power Dissipation
VDC
30
-0.7
24VDC Input Models
VDC
18
-0.7
12VDC Input Models
VDC
9
-0.7
5VDC Input Models
Input Surge Voltage
( 1000 mS )
Unit.
Max.
Min.
Parameter
Absolute Maximum Ratings
Exceeding these values can damage the module.These are not continuous operating ratings.
Internal Capacitor
Input Filter
A
0.3
---
---
All Models
Reverse Polarity Input Current
26.4
24
21.6
24V Input Models
13.2
12
10.8
12V Input Models
VDC
5.5
5
4.5
5V Input Models
Input Voltage Range
Unit
Max.
Typ.
Min.
Model
Parameter
Input Specifications
Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
79
4
53
1
67
15
MBU118
79
4
53
1.5
84
12
MBU117
76
5
54
2
110
9
MBU116
70
8
7
60
4
200
5
24
(21.6 ~ 26.4)
MBU115
80
4
105
1
67
15
MBU114
79
5
106
1.5
84
12
MBU113
77
5
107
2
110
9
MBU112
71
9
13
117
4
200
5
12
(10.8 ~ 13.2)
MBU111
78
6
258
1
67
15
MBU104
77
7
262
1.5
84
12
MBU103
76
8
260
2
110
9
MBU102
69
11
30
290
4
200
5
5
(4.5 ~ 5.5)
MBU101
Efficiency
% (Typ.)
Load
Regulation
% (Max.)
Input
Current
No Load
mA (Typ.)
Input
Current
Max. Load
mA (Typ.)
Output
Current
mA (Min.)
Output
Current
mA (Max.)
Output
Voltage
VDC
Input
voltage
VDC
Model
Number
Model Selection Guide
Free-Air Convection
Cooling
%
95
---
---
Humidity
]
+125
---
-40
Storage Temperature
]
+75
---
-25
Operating Temperature
Unit
Max.
Typ.
Min.
Conditions
Parameter
Environmental Specifications
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-2-
TOTAL POWER INT'L
MBU100
Typical Applications
Connecting Pin Patterns
(2.54 mm / 0.1 inch grids )
kHz
110
90
50
Switching Frequency
pF
100
60
---
100KHz,1V
Isolation Capacitance
M[
---
---
1000
500VDC
Isolation Resistance
VDC
---
---
1000
60 Seconds
Rated Isolation Voltage
Unit
Max.
Typ.
Min.
Conditions
Parameter
General Specification
0.5 Second Max.
Output Short Circuit
%/]
{0.02
{0.01
---
Temperature Coefficient
%
---
---
120
Over Load
mV rms.
5
---
---
Ripple & Noise (20MHz)
mV P-P
200
---
---
Over Line,Load & Temp.
Ripple & Noise (20MHz)
mV P-P
150
100
---
Ripple & Noise (20MHz)
%
See Model Selection Guide
Io=20% to 100%
Load Regulation
%
{1.5
{1.2
---
For Vin Change 1%
Line Regulation
%
{3.0
{1.0
---
Output Voltage Accuracy
Unit
Max.
Typ.
Min.
Conditions
Parameter
Output Specifications
100mA Slow - Blow Type
200mA Slow - Blow Type
500mA Slow - Blow Type
24V Input Models
12V Input Models
5V Input Models
Input Fuse Selection Guide
+Out
-Out
+Vin
-Vin
Single Output
DC / DC
Converter
Load
DC Power
Source
+
-
Fuse
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-3-
TOTAL POWER INT.
MBU100
Derating Curve
5V Output Only
All Other Output
NOTE:
1. Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
2. Other input and output voltage may be available,Please contact factory.
3. Specifications subject to change without notice.
-25
-10
0
20
60
40
80
100
125
Output
Power
%
Ambient Temperature
O
C
Output
Power
%
20
40
60
80
100
0
20
40
60
80
100
0
-3.3% /
O
C
-25
-10
0
20
60
40
80
100
125
Output
Power
%
Ambient Temperature
O
C
Output
Power
%
20
40
60
80
100
0
20
40
60
80
100
0
-4.0% /
O
C
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-4-
TOTAL POWER INT'L