SPECIFICATION
MPS-45-3.3
MPS-45-5
MPS-45-7.5
MPS-45-12
MPS-45-13.5 MPS-45-15
MPS-45-24
MPS-45-27
MPS-45-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSH CURRENT(max.)
LEAKAGE CURRENT
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
AC CURRENT
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
8A
8A
5.4A
3.7A
3.3A
3A
1.9A
1.7A
1A
0 ~ 10.7A
0 ~ 10.5A
0 ~ 7A
0 ~ 4.4A
0 ~ 3.9A
0 ~ 3.5A
0 ~ 2.2A
0 ~ 1.95A
0 ~ 1.1A
26.4W
40W
40.5W
44.4W
44.6W
45W
45.6W
45.9W
48W
52W(+3.3V:35W)with 18CFM min. Forced air convection
80mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
3.0%
3.0%
3.0%
2.0%
90 ~ 264VAC
127 ~ 370VDC
47 ~ 440Hz
65%
72%
75%
76%
76%
77%
78%
78%
78%
1.2A/115VAC
0.7A/230VAC
COLD START 20A/115VAC
40A/230VAC
<0.3mA / 264VAC
53 ~ 75W (3.3V:36 ~ 55W)
rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +85
, 10 ~ 95% RH
0.04%/
(0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
366.1Khrs min.
MIL-HDBK-217F (25
)
127*76.2*28mm (L*W*H)
0.18Kg; 72pcs/15.1Kg/1.35CUFT
800ms, 30ms, 20ms/230VAC
1200ms, 30ms, 12ms/115VAC at full load
-10 ~ +60
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
SAFETY STANDARDS
HARMONIC CURRENT
EMS IMMUNITY
UL2601-1, TUV EN60601-1, IEC601-1 Approved
Compliance to EN55011 (CISPR11) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN60601-1-2 Medical level, criteria A
45W Single Output Medical Type
M P S - 4 5
s e r i e s
Universal AC input / Full range
Low leakage current
0.3mA
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45KHz
3 years warranty
Features :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
EMI CONDUCTION & RADIATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4KVAC
I/P-FG:1.5KVAC
O/P-FG:SHORT
I/P-O/P, I/P-FG:100M Ohms/500VDC
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
OUTPUT POWER (max.)
3.8 ~ 4.46V
5.75 ~ 6.75V 8.63 ~ 10.1V 13.8 ~ 16.2V 15.5 ~ 18.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31 ~ 36.45V
55.2 ~ 64.8V
VOLTAGE ADJ. RANGE
2.97 ~ 3.63V 4.5 ~ 5.5V
6.75 ~ 8.25V 10.8 ~ 13.2V 12.2 ~ 14.85V 13.5 ~ 16.5V
21.6 ~ 26.4V 24.3 ~ 29.7V
43.2 ~ 52.8V
TOTAL POWER INT'L