PPS65 SWITCHING MODE 65W OPEN FRAME POWER SUPPLIES
KEY FEATURES
*Universal input
*Built-in EMI filter
*Optional
12VDC/
24VDC/
48VDC input
APPLICATIONS
*Telecommunications
*Computer peripherals/Lan & Hub
*Test & industrial equipments
*Medical instruments
*Business machines
ELECTRICAL SPECIFICATIONS
INPUT
*Input range-----------90~264 VAC, universal
*Frequency------------47~63Hz
*Inrush current--------30A typical ,Cold start
@25,115VAC
*Efficiency------------65%~80% typical at full load
*EMI filter------------
FCC Class B conducted, CISPR 22
Class B conducted, EN55022 class B
Conducted
*Line regulation----- +/- 0.5% typical
OUTPUT
*Maximum power----65W with 15 CFM forced air
(Refer next page)
*Hold-up time --------10ms typical at full load and 115 VAC
nominal line
*Overload protection-Short circuit protection
*Overvoltage
protection ------------Main output 20% to 40% above
nominal output
*Ripple/Noise -------- +/- 1% Max. @full load
(Optional +/-0.5% per inquiry)
65W
40W
25W
10W
0W
32.5W
20W
Power Derating Curve
15 CFM Forced Air Cooling
0
10 20 30
40
50
60
70
Ambient Temperature( C)
Natural
Convection
Cooling
Output
Power
(Watts)
EMI & EMC
*FCC part 15, Class B
*CISPR 22 / EN55022, Class B
*VCCI ,Class 2
*CE, EN61000-3-2 (Class A) and 3 ; EN61000-4-2,
-3 , -4 , -5 , -6 and -11
SAFETY APPROVAL
*UL1950 / c UL
*Optional CSA 22.2, LEVEL 3 (COMPLY WITH)
*TUV EN60950
*Optional UL 2601 (EMI Class A)(COMPLY WITH)
ENVIRONMENTAL
*Operating temperature :
0 to
50
ambient; derate each output at 2.5% per
degree from 50to 70
*Humidity:
Operating; non-condensing, 5% to 95%
*Vibration :
10~55 Hz at 1G 3 minutes period, 30 minutes along
X, Y and Z axis
*Storage temperature:
-40 to 85
*Temperature coefficient:
+/- 0.05% per degree C
*MTBF demonstrated:
>100,000 hours at full load and 25ambient
conditions
TOTAL POWER, INT. TEL:877-646-0900 FAX:978-453-7395
E-mail: sales@total-power.com http://www.total-power.com
-1-
TOTAL POWER INT'L
TPG65 Open Frame P/S
TPG65 SWITCHING MODE 65W OPEN FRAME POWER SUPPLIES
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT(NOTE1)
MINIMUM OUTPUT
CURRENT
TOTAL
REGULATION(NOTE3)
RIPPLE & NOISE
%P-P(NOTE2)
PEAK OUTPUT
POWER(NOTE1)
SINGLE OUTPUT MODEL SELECTION CHART
TPG65-15
+3.3V
10% Typical 20A 23A 2A
5%
1.5% 75W Typical
TPG65-10
+ 5V
10% Typical
13A
15A
0A
3%
1%
75W Typical
TPG65-11
+12V
10% Typical 5.4A 6.2A 0A
3%
1% 75W Typical
TPG65-12
+15V
10% Typical
4.3A
4.9A
0A
3%
1%
75W Typical
TPG65-13
+24V
10% Typical 2.7A 3.1A 0A
3%
1% 75W Typical
TPG65-S5
+48V
10% Typical
1.3A
1.5A
0A
3%
1%
75W Typical
TPG65-16
+10V
10% Typical 6.5A 7.4A 0A
3%
1% 75W Typical
TPG65-18
+20V
10% Typical
3.25A
3.7A
0A
3%
1%
75W Typical
TPG65-19
+36V
10% Typical
1.8A
2A
0A
3%
1%
75W Typical
DUAL OUTPUT MODEL SELECTION CHART
+3.3V
10% Typical
9.7A
11.1A
0.97A
5%
1.5%
TPG65-20
+ 5V
Fixed
6.5A
7.4A
0.65A
5%
1%
75W Typical
+ 5V
10% Typical
12A
13.8A
1.2A
5%
1%
TPG65-21
+12V
Fixed
1A
1.2A
0.1A
5%
1%
75W Typical
+5 V
10% Typical
6A
6.9A
0.6A
5%
1%
TPG65-22
+12V
Fixed
3A
3.5A
0.3A
5%
1%
75W Typical
+5 V
10% Typical
6A
6.9A
0.6A
5%
1%
TPG65-23
+24V
Fixed
1.5A
1.7A
0.15A
5%
1%
75W Typical
+12V
10% Typical
3A
3.5A
0.3A
5%
1%
TPG65-24
-12V
Fixed
3A
3.5A
0.3A
10%
1%
75W Typical
+3.3V
10% Typical
10A
11.5A
1A
5%
1.5%
TPG65-25
+12V
Fixed
1A
1.2A
0.1A
5%
1%
75W Typical
+3.3V
10% Typical
15A
17.3A
1.5A
5%
1.5%
TPG65-26
-48V
Fixed
0.4A
0.5A
0.04A
10%
1%
75W Typical
+5V
10% Typical
8A
9.2A
0.8A
5%
1%
TPG65-27
-5V
Fixed
2A
2.3A
0.2A
10%
1%
75W Typical
TRIPLE OUTPUT MODEL SELECTION CHART
+ 5V
10% Typical
6A
6.9A
0.6A
5%
1%
+12V
Fixed
2.2A
2.5A
0.22A
5%
1%
TPG65-31
- 12V
Fixed
0.35A
0.4A
0.04A
10%
1%
75W Typical
+ 5V
10% Typical
6A
6.9A
0.6A
5%
1%
+15V
Fixed
2.2A
2.5A
0.22A
5%
1%
TPG65-32
-15V
Fixed
0.35A
0.4A
0.04A
10%
1%
75W Typical
+ 5V
10% Typical
5A
6.9A
0.5A
5%
1%
-5V
Fixed
0.8A
1.4A
0.08A
5%
1%
TPG65-T3Y
-+12V
Fixed
3.5A
1.4A
0.35A
10%
1%
75W Typical
+ 5V
10% Typical
6A
6.9A
0.6A
5%
1%
+24V
Fixed
1A
2.3A
0.1A
5%
1%
TPG65-31B
-12V
Fixed
1A
1.2A
0.1A
10%
1%
75W Typical
+3.3V
10% Typical
10A
11.5A
1A
5%
1.5%
+5V
Fixed
2A
2.3A
0.2A
5%
1%
TPG65-36
+12V
Fixed
1.25A
1.4A
0.13A
10%
1%
75W Typical
+5V
10% Typical
1A
6.9A
0.1A
5%
1%
+15V
Fixed
1.6A
2.5A
0.16A
5%
1%
TPG65-38
+48V
Fixed
0.75A
1.4A
0.08A
10%
1%
75W Typical
+3.3V
10% Typical
13.5A
15.5A
1.35A
5%
1.5%
+12V
Fixed
1.5A
1.7A
0.15A
5%
1%
TPG65-39
+5V
Fixed
1A
1.2A
0.1A
10%
1%
75W Typical
TOTAL POWER, INT. TEL:877-646-0900 FAX:978-453-7395
E-mail: sales@total-power.com http://www.total-power.com
-2-
TPG65 SWITCHING MODE 65W OPEN FRAME POWER SUPPLIES
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT(NOTE1)
MINIMUM OUTPUT
CURRENT
TOTAL
REGULATION(NOTE3)
RIPPLE & NOISE
%P-P(NOTE2)
PEAK OUTPUT
POWER(NOTE1)
NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, input not less nominal line, 0.1F and 47F Cap. on outputs.
3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed.
4) Detailed engineering specification of each model is available for inquiry.
5) Special output voltage/current inquiry is welcomed.
6) Specifications subject to change without notice.
7) 25% derated if 24 VDC input version; 50% derated if 12 VDC input version.
TOTAL POWER, INT. TEL:877-646-0900 FAX:978-453-7395
E-mail: sales@total-power.com http://www.total-power.com
-3-