ChipFind - документация

Электронный компонент: TPS100-42

Скачать:  PDF   ZIP
TPS100 SWITCHING MODE 90W U CHANNEL POWER SUPPLIES
KEY FEATURES
*Universal input
*Built-in EMI filter
*Optional remote sense on main output
*Optional constant current charger
*Optional
12VDC/
24VDC/
48VDC input
*Optional cover
*Optional constant current change (for single output)
APPLICATIONS
*Telecommunications/Business machines
*Computer peripherals/Medical instruments
*Test & industrial equipments
ELECTRICAL SPECIFICATIONS
INPUT
*Input range-----------90~264 VAC, universal
*Frequency------------47~63Hz
*Inrush current--------38A typical, Cold start
@25,115VAC
*Efficiency------------65%~85% typical at full load
*EMI filter------------
FCC Class B conducted, CISPR 22
Class B conducted, EN55022 class B
Conducted
*Line regulation----- +/- 0.5% typical
OUTPUT
*Maximum power----90W convection (Refer next page)
*Hold-up time --------10ms typical at full load and 115 VAC
nominal line
*Overload protection-Short circuit protection
*Overvoltage
protection ------------Main output 20% to 40% above
nominal output
*Ripple/Noise -------- +/- 1% Max. @full load
(Optional +/-0.5 % per inquiry)
120W
90W
60W
30W
0W
45W
Power Derating Curve
0
10 20 30
40
50
60
70
Ambient Temperature( C)
Natural
Convection
Cooling
Output
Power
(Watts)
EMI & EMC
*FCC part 15, Class B
*CISPR 22 / EN55022, Class B
*VCCI ,Class 2
*CE, EN61000-3-2 (Class A) and 3 ; EN61000-4-2,
-3 , -4 , -5 , -6 and -11
SAFETY APPROVAL
*UL1950 / c UL
*Optional CSA 22.2, LEVEL 3 (COMPLY WITH)
*TUV EN60950
*Optional UL 2601(EMI Class A)(COMPLY WITH)
ENVIRONMENTAL
*Operating temperature :
0 to
50
ambient; derate each output at 2.5% per
degree from 50to 70
*Humidity:
Operating; non-condensing, 5% to 95%
*Vibration :
10~55 Hz at 1G 3 minutes period, 30 minutes along
X, Y and Z axis
*Storage temperature:
-40 to 85
*Temperature coefficient:
+/- 0.05% per degree C
*MTBF demonstrated:
>100,000 hours at full load and 25ambient
conditions
TOTAL POWER INT'L. TEL:877-646-0900 FAX:978-453-7395
E-mail:sales@total-power.com http://www.total-power.com
-1-
TOTAL POWER INT'L
TPS100 SWITCHING MODE 90W U CHANNEL POWER SUPPLIES
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT(NOTE1)
MINIMUM OUTPUT
CURRENT
TOTAL
REGULATION(NOTE3)
RIPPLE & NOISE
%P-P(NOTE2)
PEAK OUTPUT
POWER(NOTE1)
SINGLE OUTPUT MODEL SELECTION CHART
TPS100-10
+5V
10% Typical 18A 29.7A 0A
3%
1% 150W Typical
TPS100-11
+12V
10% Typical
7.5A
12.4A
0A
3%
1%
150W Typical
TPS100-12
+15V
10% Typical 6A 9.9A 0A
3%
1% 150W Typical
TPS100-13
+24V
10% Typical
3.75A
6.2A
0A
3%
1%
150W Typical
TPS100-14
+48V
10% Typical 1.875A 3.1A 0A
3%
1% 150W Typical
TPS100-15
+13.5V
10% Typical
6.66A
10.9A
0A
3%
1%
150W Typical
TPS100-16
+56V
10% Typical 1.6A 2.6A 0A
3%
1% 150W Typical
TPS100-17
+18V
10% Typical
5A
2.6A
0A
3%
1%
150W Typical
TPS100-18
+3.3V
10% Typical 25A 41.3A 0A
5%
1.5% 150W Typical
DUAL OUTPUT MODEL SELECTION CHART
+5 V
10% Typical
10A
16.5A
1A
5%
1%
TPS100-20
+12V
Fixed
4.2A
6.9A
0.42A
5%
1%
150W Typical
+5 V
10% Typical
10A
16.5A
1A
5%
1%
TPS100-21
+24V
Fixed
2.2A
3.6A
0.22A
5%
1%
150W Typical
+5 V
10% Typical
10A
16.5A
1A
5%
1%
TPS100-22
- 5 V
Fixed
10A
16.5A
1A
5%
1%
150W Typical
+12V
10% Typical
4.2A
6.9A
0.42A
5%
1%
TPS100-23
- 12 V
Fixed
4.2A
6.9A
0.42A
5%
1%
150W Typical
+15 V
10% Typical
3.4A
5.6A
0.34A
5%
1%
TPS100-24
- 15 V
Fixed
3.4A
5.6A
0.34A
5%
1%
150W Typical
+3.3V
10% Typical
17A
28A
1.7A
5%
1.5%
TPS100-25
+12 V
Fixed
1A
1.6A
0.1A
5%
1%
150W Typical
+ 5 V
10% Typical
1A
1.6A
0.1A
5%
1%
TPS100-26
+48V
Fixed
2A
3.3A
0.2A
5%
1%
150W Typical
TRIPLE OUTPUT MODEL SELECTION CHART
+ 5V
10% Typical
10A
16.5A
1A
5%
1%
TPS100-30
+12V
Fixed
4A
6.6A
0.4A
5%
1%
- 5 V
Fixed
0.6A
1A
0.06A
10%
1%
150W Typical
+ 5V
10% Typical
10A
16.5A
1A
5%
1%
TPS100-31
+12V
Fixed
4A
6.6A
0.4A
5%
1%
-12V
Fixed
0.6A
1A
0.06A
10%
1%
150W Typical
+ 5V
10% Typical
10A
16.5A
1A
5%
1%
TPS100-32
+15V
Fixed
2.8A
4.6A
0.28A
5%
1%
-15V
Fixed
0.6A
1A
0.06A
10%
1%
150W Typical
+ 5V
10% Typical
14A
23.1A
1.4A
5%
1%
+15V
Fixed
2A
3.3A
0.2A
5%
1%
TPS100-33
- 5 V
Fixed
0.5A
0.8A
0.05A
10%
1%
150W Typical
+ 5V
10% Typical
13A
21.5A
1.3A
5%
1%
+15V
Fixed
2A
3.3A
0.2A
5%
1%
TPS100-34
-12V
Fixed
0.6A
1A
0.06A
10%
1%
150W Typical
+ 5 V
10% Typical
9A
14.9A
0.9A
5%
1%
+24V
Fixed
2A
3.3A
0.2A
5%
1%
TPS100-35
-12V
Fixed
0.6A
1A
0.06A
10%
1%
150W Typical
+ 5V
10% Typical
9A
14.9A
0.9A
5%
1%
+12V
Fixed
3.5A
5.8A
0.35A
5%
1%
TPS100-36
- 12V
Fixed
0.6A
1A
0.06A
10%
1%
150W Typical
+ 5V
10% Typical
9A
14.9A
0.9A
5%
1%
+12V
Fixed
3.5A
5.8A
0.35A
5%
1%
TPS100-37
+24V
Fixed
0.6A
1A
0.06A
10%
1%
150W Typical
+ 5V
10% Typical
6A
9.9A
0.6A
5%
1%
+12V
Fixed
2A
3.3A
0.2A
5%
1%
TPS100-38
+48V
Fixed
1A
1.6A
0.1A
10%
1%
150W Typical
TOTAL POWER INT'L. TEL:877-646-0900 FAX:978-453-7395
E-mail:sales@total-power.com
http://www.total-power.com
-2-
TPS100 SWITCHING MODE 90W U CHANNEL POWER SUPPLIES
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT(NOTE1)
MINIMUM OUTPUT
CURRENT
TOTAL
REGULATION(NOTE3)
RIPPLE & NOISE
%P-P(NOTE2)
PEAK OUTPUT
POWER(NOTE1)
QUAD OUTPUT MODEL SELECTION CHART
+ 5V
10% Typical
10A
16.5A
1A
5%
1%
+12V
Fixed
3.5A
5.8A
0.35A
5%
1%
- 12V
Fixed
0.5A
0.8A
0.05A
10%
1%
TPS100-40
- 5 V
Fixed
0.5A
0.8A
0.05A
10%
1%
150W Typical
+ 5V
10% Typical
10A
16.5A
1A
5%
1%
+12V
Fixed
3A
5A
0.3A
5%
1%
- 12V
Fixed
1A
1.6A
0.1A
10%
1%
TPS100-41
- 5 V
Fixed
1A
1.6A
0.1A
10%
1%
150W Typical
+ 5V
10% Typical
10A
16.5A
1A
5%
1%
+12V
Fixed
2A
3.3A
0.2A
5%
1%
- 15V
Fixed
1A
1.6A
0.1A
10%
1%
TPS100-42
+15V
Fixed
1A
1.6A
0.1A
10%
1%
150W Typical
+ 5V
10% Typical
6A
9.9A
0.6A
5%
1%
+12V
Fixed
2.5A
4.1A
0.25A
5%
1%
-15V
Fixed
1A
1.6A
0.1A
10%
1%
TPS100-43
- 12V
Fixed
1A
1.6A
0.1A
10%
1%
150W Typical
+ 5V
10% Typical
6A
9.9A
0.6A
5%
1%
+12V
Fixed
1A
1.6A
0.1A
5%
1%
- 12V
Fixed
1A
1.6A
0.1A
10%
1%
TPS100-44
+48V
Fixed
1A
1.6A
0.1A
10%
1%
150W Typical
+ 5V
10% Typical
6A
9.9A
0.6A
5%
1%
+12V
Fixed
2A
3.3A
0.2A
5%
1%
- 12V
Fixed
1A
1.6A
0.1A
10%
1%
TPS100-45
+24V
Fixed
1.5A
2.5A
0.15A
10%
1%
150W Typical
+ 5V
10% Typical
2.5A
4.1A
0.25A
5%
1%
+12V
Fixed
1A
1.6A
0.1A
5%
1%
- 12V
Fixed
2A
3.3A
0.2A
10%
1%
TPS100-46
+36V
Fixed
1.5A
2.5A
0.15A
10%
1%
150W Typical
NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, 0.1F and 47F Cap. on outputs.
3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed.
4) Detailed engineering specification of each model is available for inquiry.
5) Special output voltage/current inquiry is welcomed.
6) Specifications subject to change without notice.
7) 25% derated if 24 VDC input version; 50% derated if 12 VDC input version; 25% derated if additional cover.
TOTAL POWER INT'L TEL:877-646-0900 FAX:978-453-7395
E-mail:sales@total-power.com http://www.total-power.com
-3-