Data Sheet
Part Number 856417
1960 MHz SAW Filter
Features
For GSM-1900 applications
Usable bandwidth of 60 MHz
Compatible with leading chipset suppliers
Ultra low loss
Single-ended input, 50
Balanced output, 200
Chip Scale Package (CSP)
Hermetic
Package
Pin Configuration
Surface Mount 1.50 x 1.50 x 0.76 mm
Bottom View
1
2
3
6
5
4
Pin No.
Description
2
Input
4,6
Output
1,3,5
Case
ground
0.25
0.55
0.40
0.60
1.35
1.50
1.35
1.50
0.76 NOM.
0.84 MAX.
Dimensions shown are nominal in millimeters
All tolerances are
0.10mm
Body: Al
2
O
3
ceramic
Lid: Kovar or Alloy 42, Au over Ni plated
Terminations: Au plating 0.5 - 1.0
m,
over a 2 - 6
m Ni plating
Subject to change or obsolescence without notice
Rev C
08-Dec-2004
Page 1 of 7
Data Sheet
Part Number 856417
1960 MHz SAW Filter
Electrical Specifications
(1)
Operating Temperature Range:
(2)
+25
o
C
Parameter
(3)
Minimum
Typical
Maximum
Unit
Center Frequency
- 1960 -
MHz
Maximum Insertion Loss
1930
-
1990
MHz
-
1.5
2.1
dB
Absolute Attenuation
100
-
1830
MHz
1830
-
1902
MHz
1902
-
1910
MHz
2010
-
2030
MHz
2030
-
2070
MHz
2070
-
3000
MHz
3000
-
5790
MHz
5790
-
6000
MHz
25
10
7
5
10
16
30
35
35
17
10
6.5
15
18
40
40
-
-
-
-
-
-
-
-
dB
dB
dB
dB
dB
dB
dB
dB
Output Amplitude Balance (|S
31
/S
21
|)
1930
-
1990
MHz
-1.5
1.3
1.5
dB
Output Phase Balance [(S
31
)-S
21
+180]
1930
-
1990
MHz
-10
2
10
degree
Input/Output VSWR
1930
-
1990
MHz
-
2.0
2.5
-
Source Impedance
(4)
- 50 -
Load Impedance (Balanced)
(4)
- 200||18nH -
Notes:
1. All specifications are based on the test circuit shown below
2. In production, devices will be tested at room temperature to a guardbanded specification to ensure electrical compliance over
temperature
3. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances
4. This is the optimum impedance in order to achieve the performance shown
Test Circuit:
50
Single-ended
Input
1,3,5
2
4
50
6
200
18nH
200
Balanced
Output
Subject to change or obsolescence without notice
Rev C
08-Dec-2004
Page 2 of 7
Data Sheet
Part Number 856417
1960 MHz SAW Filter
Electrical Specifications
(1)
Operating Temperature Range:
(2)
-10 to +80 C
Parameter
(3)
Minimum
Typical
Maximum
Unit
Center Frequency
- 1960 -
MHz
Maximum Insertion Loss
1930
-
1990
MHz
-
1.5
2.3
dB
Absolute Attenuation
100
-
1830
MHz
1830
-
1902
MHz
1902
-
1910
MHz
2010
-
2030
MHz
2030
-
2070
MHz
2070
-
3000
MHz
3000
-
5790
MHz
5790
-
6000
MHz
25
10
6
5
10
16
30
35
35
17
10
6.5
15
18
40
40
-
-
-
-
-
-
-
-
dB
dB
dB
dB
dB
dB
dB
dB
Output Amplitude Balance (|S
31
/S
21
|)
1930
-
1990
MHz
-1.5
1.3
1.5
dB
Output Phase Balance [(S
31
)-S
21
+180]
1930
-
1990
MHz
-10
2
10
degree
Input/Output VSWR
1930
-
1990
MHz
-
2.0
2.5
-
Source Impedance
(4)
- 50 -
Load Impedance (Balanced)
(4)
- 200||18nH -
Notes:
1. All specifications are based on the test circuit shown below
2. In production, devices will be tested at room temperature to a guardbanded specification to ensure electrical compliance over
temperature
3. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances
4. This is the optimum impedance in order to achieve the performance shown
Test Circuit:
50
Single-ended
Input
1,3,5
2
4
50
6
200
18nH
200
Balanced
Output
Subject to change or obsolescence without notice
Rev C
08-Dec-2004
Page 3 of 7
Data Sheet
Part Number 856417
1960 MHz SAW Filter
Electrical Specifications
(1)
Operating Temperature Range:
(2)
-25 to +80 C
Parameter
(3)
Minimum
Typical
Maximum
Unit
Center Frequency
- 1960 -
MHz
Maximum Insertion Loss
1930
-
1990
MHz
-
1.5
2.5
dB
Absolute Attenuation
100
-
1830
MHz
1830
-
1902
MHz
1902
-
1910
MHz
2010
-
2030
MHz
2030
-
2070
MHz
2070
-
3000
MHz
3000
-
5790
MHz
5790
-
6000
MHz
25
10
6
5
10
16
30
35
35
17
10
6.5
15
18
40
40
-
-
-
-
-
-
-
-
dB
dB
dB
dB
dB
dB
dB
dB
Output Amplitude Balance (|S
31
/S
21
|)
1930
-
1990
MHz
-1.5
1.3
1.5
dB
Output Phase Balance [(S
31
)-S
21
+180]
1930
-
1990
MHz
-10
2
10
degree
Input/Output VSWR
1930
-
1990
MHz
-
2.0
2.5
-
Source Impedance
(4)
- 50 -
Load Impedance (Balanced)
(4)
- 200||18nH -
Notes:
1. All specifications are based on the test circuit shown below
2. In production, devices will be tested at room temperature to a guardbanded specification to ensure electrical compliance over
temperature
3. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances
4. This is the optimum impedance in order to achieve the performance shown
Test Circuit:
50
Single-ended
Input
1,3,5
2
4
50
6
200
18nH
200
Balanced
Output
Subject to change or obsolescence without notice
Rev C
08-Dec-2004
Page 4 of 7
Data Sheet
Part Number 856417
1960 MHz SAW Filter
Typical Performance
(at +25
o
C)
Subject to change or obsolescence without notice
Rev C
08-Dec-2004
Page 5 of 7