WIRELESS COMMUNICATIONS DIVISION
For additional information and latest specifications, see our website: www.triquint.com
1
Product Description
The TQ1200 through TQ1209 are a family of directional passive couplers. These devices
consist of two broadside-coupled transmission lines. The first transmission line connects the
input port to the thru port and the second transmission line connects the coupled port to the
isolated port.
P/N
Freq
(MHz)
IL
(dB)
Coup
(dB)
Isol
(dB)
VSWR
(max)
Pow
(W)
TQ1200
815.0
10.0
0.17
(max.)
20.3
2.0 (max.)
27
(min.)
1.4
(max.)
3
TQ1201
836.5
12.5
0.17
(max.)
19.9
2.0 (max.)
26
(min.)
1.4
(max.)
1
TQ1202
836.5
12.5
0.40
(max.)
14.6
2.0 (max.)
24
(min.)
1.4
(max.)
1
TQ1203
897.5
17.5
0.20
(max.)
19.4
2.0 (max.)
25
(min.)
1.4
(max.)
3
TQ1204
1441.0
12.0
0.28
(max.)
16.8
2.0 (max.)
22
(min.)
1.4
(max.)
1
TQ1205
1880.0
30
0.27
(max.)
18.2
2.0 (max.)
22
(min.)
1.4
(max.)
1
TQ1206
1880.0
30.0
0.29
(max.)
16.5
2.0 (max.)
21.0
(min.)
1.4
(max.)
3
TQ1207
1880.0
30.0
0.45
(max.)
13.2
2.0 (max.)
18
(min.)
1.4
(max.)
1
TQ1208
1950
30.0
0.31
(max.)
15.8
2.0 (max.)
20.5
(min.)
1.4
(max.)
3
TQ1209
1960
30.0
0.37
(max.)
14.0
2.0 (max.)
18.7
(min.)
1.4
(max.)
1
Note: Specifications are ambient temperature range from -40
C to 85
C.
TQ1200-TQ1209
DATA SHEET
Couplers
Features
Small size: MLF 2x2
Low Insertion Loss
High Power Capacity
Excellent Isolation
Low VSWR
Applications
Wireless Communications
Power Sampling/Level Sampling
General Purpose Apps
Port 1
Port 3
Port 2
Port 4
TQ1200-1209
Data Sheet
2
For additional information and latest specifications, see our website: www.triquint.com
Absolute Maximum Ratings
Parameter
Value
Units
Operating Temperature
-40 to 85
C
Storage Temperature
-60 to 150
C
Block Diagram: 1200-1209
Pin 4
COUP
Pin 5
ISOL
Pin 3
IN
Pin 1
THRU
Pin 2
GND
PIN-OUT FUNCTIONAL DESCRIPTION
Pin
Name
Description
1
Thru
Thru port
2
GND
Ground
3
IN
Input port
4
Coup
Coupled port
5
Isol
Isolation port
TQ1200-1209
Data Sheet
For additional information and latest specifications, see our website: www.triquint.com
3
Typical Performance
Test Conditions, unless Otherwise Specified: Tc=+25C
TQ1200 Coupling
0
5
10
15
20
25
30
500
1000
1500
2000
2500
Frequency (MHz)
Coupl
i
ng (
d
B)
Coupling
TQ1201 Coupling
0
5
10
15
20
25
30
500
1000
1500
2000
2500
Frequency (MHz)
Coupl
i
ng (
d
B)
Coupling
TQ1200 Insertion Loss
0
0.5
1
1.5
2
2.5
3
500
1000
1500
2000
2500
Frequency (MHz)
I
n
ser
t
i
on Loss (
d
B)
Insertion Loss
TQ1201 Insertion Loss
0
0.5
1
1.5
2
2.5
3
500
1000
1500
2000
2500
Frequency (MHz)
I
n
ser
t
i
on Loss (
d
B)
Insertion Loss
TQ1200 Isolation
0
5
10
15
20
25
30
35
40
500
1000
1500
2000
2500
Frequency (MHz)
I
s
ol
at
i
on (
d
B)
Isolation
TQ1201 Isolation
0
5
10
15
20
25
30
35
40
500
1000
1500
2000
2500
Frequency (MHz)
I
s
ol
at
i
on (
d
B)
Isolation