ChipFind - документация

Электронный компонент: COMPAC

Скачать:  PDF   ZIP
Total Power
Part No.
Dimensions
Single Outputs: 50-200W
VI-LC
8.6" x 2.5" x 0.99"
(218,4 x 63,5 x 25,2mm)
100-400W
VI-MC
8.6" x 4.9" x 0.99"
(218,4 x 124,5 x 25,2mm)
300-600W
VI-NC
8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
Dual Outputs:
100-400W
VI-PC
8.6" x 4.9" x 0.99"
(218,4 x 124,5 x 25,2mm)
150-600W
VI-QC
8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
Triple Outputs: 150-600W
VI-RC
8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
Product Highlights
ComPAC delivers up to 600W from
one, two, or three outputs in a package
just 0.99" (25,2mm) in height with the
field proven performance, high
efficiency and high reliability inherent
in Vicor's component level power
converters. ComPAC meets British
Telecom and European norms for input
surge withstand and meets conducted
emissions of EN55022 Class B.
ComPAC is offered with input voltage
ranges optimized for industrial and
telecommunication applications and
provides extended input overvoltage
capability, input reverse polarity
protection, undervoltage lockout, and
master disable.
Features
Inputs 24, 48, and 300Vdc
Any output: 1 to 95Vdc
Input surge withstand:
British Telecom BTR 2511,
EN-61000-4-5
Meets British Telecom BTR 2511,
EN55022 Class B conducted emissions
UL, CSA, TV (IEC 950)
CE marked
80-90% efficiency
Up to 10W/cubic inch
Reverse polarity protected
Master disable
Overvoltage shutdown
DC-DC Switchers
50 to 600W
1-3 Outputs
Input Voltage
Nominal
Range
1 = 24V
21 - 32V (1)
W = 24V
18 - 36V (1)
3 = 48V
42 - 60V (2)
N = 48V
36 - 76V (2)
6 = 300V 200 - 400V (2)
Output Voltage
Z 2V
M 10V
K 40V
Y 3.3V
1 12V
4 48V
0 5V
P 13.8V H 52V
X 5.2V
2 15V
F 72V
W 5.5V
N 18.5V D 85V
V 5.8V
3 24V
B 95V
T 6.5V
L 28V
R 7.5V
J 36V
Output Power/Current
V
out
5V
V
out
< 5V
W = 100W
20A
V = 150W
30A
U = 200W
40A
S = 300W
60A
Q = 400W
80A
Output Power/Current
V
out
5V
V
out
< 5V
S = 300W
60A
P = 450W
90A
M = 600W
120A
Product Grade
E = -10C to +85C
C = -25C to +85C
I = -40C to +85C
M = -55C to +85C
Output Power/Current
V
out
5V
V
out
< 5V
Y = 50W
10A
X = 75W
15A
W = 100W
20A
V = 150W
30A
U = 200W
40A
ComPAC Configuration Chart
Use the configuration chart at the right to define your
Vicor part number(s).
C o m PA C
TM
Max
5V
<5V
output for
Outputs
Outputs
(1)
150W
30A
(2)
200W
40A
Conduction Cooled Models Available
Add "-CC" to the end of the part number.
(Consult factory for details.)
Long Term Safe Operating Area Curves
(1% duty cycle max. Z
s
=0.5
;
for short duration transient capability refer to page 3.)
0.1 1 10ms 100 1000
800V
Normal Operating Area
I.S.W.
Full Load
300V Input
S.D.
R.E.
500V
400V
200V
500ms
276V
Normal Operating Area
I.S.W.
Full Load
0.1 1 10ms 100 1000
48V Wide Range Input
R.E.
76V
125V
36V
S.D.
S.D.
100V
500ms
0.1 1 10ms 100 1000
100V
Normal Operating Area
I.S.W.
Full Load
100V
Standard
Wide Range
24V Inputs
R.E.
32V
21V
36V
18V
S.D.
160V
0.1 1 10ms 100 1000
Normal Operating Area
I.S.W.
Full Load
48V Input
R.E.
S.D.
60V
100V
42V
I.S.W.: Input surge withstand, no degradation of performance. R.E.: Ratings Exceeded S.D.: Shutdown
ComPAC 10/02 1 of 4
ComPAC Specifications
(Typical at 25C, nominal line and 75% load, unless otherwise specified)
E-GRADE
C-, I-, M-GRADE
PARAMETER
MIN
TYP
MAX
MIN
TYP
MAX
BROWNOUT*
TRANSIENT**
UNITS
NOTES
Input Characteristics
24V
21
24
32
21
24
32
18
36
Vdc
See Fusing Information below
24V Wide
18
24
36
18
24
36
n/a
n/a
Vdc
See Fusing Information below
48V
42
48
60
42
48
60
36
72
Vdc
See Fusing Information below
48V Wide
36
48
76
36
48
76
n/a
n/a
Vdc
See Fusing Information below
300V
200
300
400
200
300
400
170
425
Vdc
See Fusing Information below
No load power dissipation
3
1.35
2
1.35
2
Watts
Master disable input current
3
4
4
mA
Sink or source into disable
(Absolute max., 20 mA)
optocoupler
Quiescent Input current
logic disable
3
7
10
7
10
mA
Current drawn from source
when disabled
Reverse polarity protection
No damage to unit with
external fuse
Output Characteristics (applies to each output individually)
Setpoint accuracy
1%
2%
0.5%
1%
V
NOM
Load/line regulation
0.5%
0.05%
0.2%
V
NOM
LL to HL, 10% to full load
Load/line regulation
1%
0.2%
0.5%
V
NOM
LL to HL, no load to full load
Output temperature drift
0.02
0.01
0.02
%/C
Over rated temperature
Long term drift
0.02
0.02
%/1k hours
Output ripple
2V, 3.3V
150mV
60mV
100mV
Vp-p
20 MHz bandwidth
5V
5%
2%
3%
Vp-p
20 MHz bandwidth
10-48V
3%
0.75%
1.5%
Vp-p
20 MHz bandwidth
Output voltage trimming
1
50%
110%
50%
110%
Total remote sense
compensation
1
0.5
0.5
Volts
0.25V max. neg. leg
OVP set point
125%
115%
125%
135%
V
NOM
Recycle power
Current limit
105%
135%
105%
125%
I
NOM
Automatic restart
Short circuit current
2
20%
140%
20%
130%
I
NOM
Thermal Characteristics
Efficiency
78-88%
80-90%
@5V and higher
Shutdown temp. -- case
90
95
105
90
95
105
C
Cool and recycle power to restart
Operating temp. -- case
85
85
C
See Thermal Curves
Isolation Characteristics
Isolation
Input to output
4,242
4,242
Vdc
Output to case
707
707
Vdc
Input to case
2,121
2,121
Vdc
Mechanical Specifications
Weight
3
19.2 (544)
19.2 (544)
Ounces (Grams)
Fusing Information
Input voltage
24V
48V
300V
LC series (200W)
10A
7A
2A
MC, PC series (400W)
20A
15A
4A
NC, QC, RC series (600W)
35A
25A
6A
Safety Agency Approvals
UL, CSA, TV, VDE, IEC 950, CE Marked
Environmental Characteristics/Product Grade Designators (Temperatures apply to product case.)
E-Grade
C-Grade
I-Grade
M-Grade
Storage temperature
-20C to +100C
-40C to +100C
-55C to +100C
-65C to +100C
Operating temperature
-10C to +85C
-25C to +85C
-40C to +85C
-55C to +85C
EMI / EMC Characteristics (Performed on selected samples representative of the ComPac product family.)
Input surge withstand
(Up to 200 mS, Z
s
= .5
, no interruption of performance, see: Long Term Safe Operating Area Curves, pg.2)
IEC 61000-4-5 level 2
Conducted Emissions
British Telecom BTR 2511, Issue 2
EN 55022, class B
ESD
IEC 61000-4-2 level 4
*Brownout 75% of rated load.
**Transient voltage for one second.
1
10V, 12V and 15V outputs, trim range 10%. Consult factory for wider trim range.
2
Output voltages of 5V or less incorporate foldback current limiting, outputs greater than 5V incorporate straight line current limiting.
3
For MC, PC series, multiply by 2; for NC, QC, RC series, multiply by 3.
ComPAC 10/02 2 of 4
Thermal Curves, 5V Output
(Standard heatsink)
Thermal Curves, 10V to 48V Output
(Standard heatsink)
0
25
50
75
100
125
150
175
200
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
e
r (W
atts)
0
50
100
150
200
250
300
350
400
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
er (W
atts)
0
75
150
225
300
375
450
525
600
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
er (W
atts)
0
25
50
75
100
125
150
175
200
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
er (W
atts)
0
50
100
150
200
250
300
350
400
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
e
r (W
atts)
0
75
150
225
300
375
450
525
600
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
e
r (W
atts)
FREE AIR
50 LFM
100 LFM
250 LFM
500 LFM
750 LFM
1000 LFM
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
LC Series
MC, PC Series
NC, QC, RC Series
LC Series
MC, PC Series
NC, QC, RC Series
Ambient Temperature (Deg. C)
Output Power (W
atts)
Output Power (W
atts)
Output Power (W
atts)
Output Power (W
atts)
Output Power (W
atts)
Output Power (W
atts)
FREE AIR
50 LFM
100 LFM
250 LFM
500 LFM
750 LFM
1000 LFM
Thermal Curves, 5V Output
(H1 heatsink)
Thermal Curves, 10 to 48V Output
(H1 heatsink)
0
75
150
225
300
375
450
525
600
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
e
r (W
atts)
0
25
50
75
100
125
150
175
200
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
er (W
atts)
0
50
100
150
200
250
300
350
400
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
e
r (W
atts)
0
75
150
225
300
375
450
525
600
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
er (W
atts)
0
25
50
75
100
125
150
175
200
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
er (W
atts)
0
50
100
150
200
250
300
350
400
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (Deg. C)
Output P
o
w
er (W
atts)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
LC Series
MC, PC Series
NC, QC, RC Series
LC Series
MC, PC Series
NC, QC, RC Series
FREE AIR
50 LFM
100 LFM
250 LFM
500 LFM
750 LFM
1000 LFM
FREE AIR
50 LFM
100 LFM
250 LFM
500 LFM
750 LFM
1000 LFM
Output Power (W
atts)
Output Power (W
atts)
Output Power (W
atts)
Output Power (W
atts)
Output Power (W
atts)
Output Power (W
atts)
ComPAC 10/02 3 of 4
Mechanical Drawings
OPTIONAL HEATSINK (H1)
STANDARD UNITS
1.12
(28,4)
1.37
(34,80)
0.99
(25,15)
0.5
(12,57)
0.41
(10,4)
9.25
.120
(235,0
3,05)
8.63
.025
(219,2
,64)
INPUTS
1
Ground
2
-Input
3
+Input
4
Disable-
5
Disable+
OUTPUTS
A
+Output
B
+Sense
C
Trim
D
-Sense
E
-Output
0.5
(12,57)
Measure case temperature on this surface.
0.41 (10,41)
2.11 (53,59)
1.53 (38,86)
1.14 (28,96)
0.75 (19,05)
12
0.150
0.005 THRU 4 PLACES
(3,81
0,13)
0
1
2
3
4
5
2.156
(54,76)
0.18
(4,6)
2.76
(70,1)
6.00
(152,4)
0.91
23,1)
2.54
(64,5)
0.20
(5,1)
0.19
(4,8)
0.20
(5,1)
E
D
C
B
A
0.25 TYP
#8-32 STUD
2 PLACES
OUTPUT 1
(
0.41 (10,41)
4.53 (115,06)
3.95 (100,33)
3.56 (90,42)
3.17 (80,52)
2.83 (71,88)
2.11 (53,59)
1.53 (38,86)
1.14 (28,96)
0.75 (19,05)
12
0.150
0.005 THRU 5 PLACES
(3,81
0,13)
#10-32 STUD
2 PLACES
1
2
3
4
5
3.58
(90,9)
3.04
(77,2)
4.96
(126,0)
4.562
(115,87)
0.18
(4,6)
6.00
(152,4)
2.76
(70,1)
2.281
(57,94)
0.20
(5,1)
0.19
(4,8)
#8-32 STUD
4 PLACES
A
E
D
C
B
A
E
D
C
B
4.
0
0.25 TYP
A
E
D
C
B
OUTPUT 1
OUTPUT 2
OUTPUT 1
12
0.150
0.005 THRU 6 PLACES
(3,81
0,13)
1
2
3
4
5
4.96
(126,0)
4.42
(112,3)
7.380
(187,45)
0.18
(4,6)
6.00
(152,4)
2.76
(70,1)
7.00
(177,8)
2.288
(58,12)
2.420
(61,47)
0.20
(5,1)
0.19
(4,8)
A
E
D
C
B
A
E
D
C
B
A
E
D
C
B
0.41 (10,41)
6.95 (176,53)
6.37 (161,80)
5.98 (151,89)
5.59 (141,99)
5.25 (133,35)
4.53 (115,06)
3.95 (100,33)
3.56 (90,42)
3.17 (80,52)
2.83 (71,88)
2.11 (53,59)
1.53 (38,86)
1.14 (28,96)
0.75 (19,05)
0
#10-32 STUD
2 PLACES
#8-32 STUD
6 PLACES
0.25 TYP
D
C
B
A
E
D
C
B
A
A
E
D
C
B
E
#10-32 STUD
2 PLACES
#8-32 STUD
2 PLACES
OUTPUT 1
OUTPUT 2
OUTPUT 1
OUTPUT 1
OUTPUT 2
OUTPUT 3
All Models
LC Series
MC, PC Series
NC, QC, RC Series
Standard Heatsink
Optional Heatsink (H1)
ComPAC 10/02 4 of 4