GENERAL DATA
Life Expectancy
Minimum operations
Mechanical
1 x 10
7
Electrical
1 x 10
5
at 30 A 120 VAC Res. (N.O.)
Operate Time (max.)
Max. 12 ms
Typical: 8 ms
Release Time (max.)
Max. 5 ms
Typical: 3.5 ms
Dielectric Strength
2500 Vrms contact to coil
(at sea level for 1 min.) 2000 Vrms between open contacts
Insulation Resistance
1000 megohms min. at 500 VDC, 20C,
50% RH
Dropout
Greater than 10% of nominal coil voltage
Ambient Temperature
At nominal coil voltage
Operating
-55C (-67F) to 100C (212F) Class B
-55C (-67F) to 125C (257F) Class F
Storage
-55C (-67F) to 130C (266F) Class B
-55C (-67F) to 155C (311F) Class F
Vibration
0.062" DA at 1055 Hz
Shock
20 g
Enclosure (optional)
P.B.T. polyester
Terminals
Tinned copper alloy, P.C. & quick connects,
.250" wide, on top
Note: Allow suitable slack on leads when wiring, and do
not subject the terminals to excessive force.
Max. Solder Temp.
270C (518F)
Max. Solder Time
5 seconds
Weight
40 grams
CONTACTS
Arrangement
SPDT (1 Form C)
SPST (1 Form A and 1 Form B)
Ratings
Resistive load:
Max. switched power: 560 W or 8310 VA
Max. switched current: 30 A (Form A)
15 A (Form B)
Max. switched voltage: 277 VAC, 28 VDC
UL Rating: See chart for UL contact ratings. AZ2150
Series meets UL 508 Group A spacing and UL 873
refrigeration and safety control requirements. AZ2151
Series meets UL 508 Group B spacing requirements.
VDE Rating:
AZ2110-1A - 25 A at 250 VAC, 10k cycles, resistive
AZ2110-1C - 20 A at 250 VAC, 10k cycles, resistive
Material
Silver cadmium oxide
Resistance
20 milliohms initially
(at rated current, voltage drop method)
COIL
Power
At Pickup Voltage
500 mW
(typical)
Max. Continuous
2.2 W at 20C (68F) ambient
Dissipation
1.8 W at 40C (104F) ambient
Temperature Rise
38C (68F) at nominal coil voltage - AZ2110
33C (59F) at nominal coil voltage - AZ2120
Temperature
Max. 130C (266F) Class B
Max. 155C (311F) Class F
AZ2110/AZ2120
10/22/03W
MINIATURE
POWER RELAY
FEATURES
30 Amp switching capability for both N.O. and
N.C. contacts
1 Form A, B and C contacts available
DC coils to 120 VDC
Low cost
Life expectancy to 10 million operations
High dielectric strength version available
Class B insulation standard
Class F (155C) version standard
Versatility of both PC and "Trace Saver" quick-connect
terminals on contacts offered on the AZ2120 version
Proof Tracking Index (PTI/CTI) 175
UL, CUR file E44211 including versions meeting UL 508
and UL 873 spacing and contact rating requirements;
VDE 132710 G (some models)
NOTES
1. All values at 20C (68F).
2. Relay may pull in with less than "Must Operate" value.
3. Other coil resistances and sensitivities available upon request. Please
contact the factory.
4. Specifications subject to change without notice.
UL/CUR File E44211 Approved Contact Ratings
Form A
Form B
Form C
Load Type
Cycles
Volts
(NO)
(NC)
NO
NC
General Purpose
100,000
125 or 240 VAC
30 A
15 A
--
15 A
(Inductive)
30,000
277 VAC
30 A
30 A
30 A
30 A
Resistive
100,000
125 or 240 VAC
30 A
15 A
--
--
100,000
30 VDC
20 A
10 A
20 A
10 A
100,000
277 VAC
20 A
--
--
--
100,000
240 VAC
15 A
--
--
--
Ballast
6,000
277 VAC
6 A
3 A
6 A
3 A
Pilot Duty
6,000
125 VAC
800 VA
290 VA
800 VA
290 VA
30,000
125 VAC
800 VA
--
690 VA
--
100,000
125 VAC
690 VA
--
470 VA
275 VA
6,000
240 VAC
1152 VA
768 VA
1152 VA
768 VA
100,000
277 VAC
764 VA
--
764 VA
--
Motor Load
6,000
125 VAC
1 HP
1
/
4
HP
1 HP
1
/
4
HP
6,000
240 VAC
2 HP
1 HP
2 HP
1 HP
30,000
125 VAC
1 HP
--
1 HP
--
100,000
125 or 277 VAC
3
/
4
HP
--
3
/
4
HP
--
Definite Purpose
30,000
125 VAC
96 LRA
33 LRA
60 LRA
33 LRA
30 FLA
10 FLA
20 FLA
10 FLA
(LRA-Locked Rotor)
100,000
125 VAC
82.8 LRA
--
82.8 LRA
--
27 FLA
--
27 FLA
--
(FLA-Full Load)
30,000
240 VAC
80 LRA
33 LRA
60 LRA
33 LRA
30 FLA
10 FLA
20 FLA
10 FLA
100,000
277 VAC
60 LRA
--
60 LRA
--
20 FLA
--
20 FLA
--
Tungsten
6,000
125 VAC
15 A
--
15 A
3 A
6,000
240 VAC
5 A
--
5 A
3 A
6,000
120 VAC
--
3 A
--
--
6,000
240 VAC
--
3 A
--
--
TV5
25,000
120 VAC
TV5
--
TV5
TV3
TV3
25,000
120 VAC
--
TV3
--
TV3
Note: See AZ2100 Data Sheet for more complete UL and CUR approved contact ratings.
RELAY ORDERING DATA
STANDARD RELAYS: UL 508; UL 873 Version - 1/8" Clearance, 1/4" Creepage
COIL SPECIFICATIONS
ORDER NUMBER*
Nominal Max.
Coil
Must
Coil
Continuous
Resistance
Operate
Form A (SPST)
Form C (SPDT)
VDC
VDC
10%
VDC
5
7.3
27
3.75
AZ21101A5D
AZ21101C5D
6
8.9
40
4.5
AZ21101A6D
AZ21101C6D
9
13.9
97
6.75
AZ21101A9D
AZ21101C9D
12
17.5
155
9.0
AZ21101A12D
AZ21101C12D
15
22.5
256
11.25
AZ21101A15D
AZ21101C15D
18
27.4
380
13.5
AZ21101A18D
AZ21101C18D
24
36.1
660
18.0
AZ21101A24D
AZ21101C24D
48
68.4
2,560
36.0
AZ21101A48D
AZ21101C48D
70
104.4
5,500
52.5
AZ21101A70D
AZ21101C70D
110
163.2
13,450
82.5
AZ21101A110D AZ21101C110D
STANDARD RELAYS: UL 508 Version - 1/16" Clearance, 1/8" Creepage
COIL SPECIFICATIONS
ORDER NUMBER*
5
7.3
27
3.75
AZ21111A5D
AZ21111C5D
6
8.9
40
4.5
AZ21111A6D
AZ21111C6D
9
13.9
97
6.75
AZ21111A9D
AZ21111C9D
12
17.5
155
9.0
AZ21111A12D
AZ21111C12D
15
22.5
256
11.25
AZ21111A15D
AZ21111C15D
18
27.4
380
13.5
AZ21111A18D
AZ21111C18D
24
36.1
660
18.0
AZ21111A24D
AZ21111C24D
48
68.4
2,560
36.0
AZ21111A48D
AZ21111C48D
70
104.4
5,500
52.5
AZ21111A70D
AZ21111C70D
110
163.2
13,450
82.5
AZ21111A110D AZ21111C110D
* Substitute "1B" in place of the "1A" to indicate 1 Form B contact. To indicate Class F version, add suffix "F".
For quick connect terminals on contacts substitute "2120" or "2121" in place of "2110" or "2111".
AZ2110/AZ2120
10/22/03W
AZ2110/AZ2120
10/22/03W
MECHANICAL DATA
AZ2110/2120 VERSION
Viewed toward
terminals
1 FORM A
(SPST-NO)
1 FORM B
(SPST-NC)
1 FORM C
(SPDT)
1 FORM A
(SPST-NO)
1 FORM B
(SPST-NC)
1 FORM C
(SPDT)
AZ2111/2121 VERSION
WIRING DIAGRAM
PC BOARD LAYOUT
AZ2110 / AZ2111
AZ2120/ AZ2121
1.165 x .010
(29.6 x 0.25)
.025 x .005
(0.63 x 0.125)
.025 x .005
(0.63 x 0.125)
.140 x .010
(3.56 x 0.25)
.140 x .010
(3.56 x 0.25)
.032 x .062
(0.81 x 1.57)
TERMINALS
.045 x .045
(1.14 x 1.14)
TERMINALS
.081 x .003
(2.06 x .076)
.043 x .003
(1. 09 x .076)
Terminal eliminated
on AZ 2110/AZ 2120
Version
Viewed toward
terminals
DIA (4 PLC'S)
.400
(10.2)
.300 (7.6)
.900 (22.86)
.150 (3.8)
.350 (8.9)
.550 (14.0)
.700 (17.8)
1.00
(25.38)
.025 x .025
(0.63 x 0.63)
TERMINALS
.991 x .010
(25.2 x 0.25)
.970
(24.65)
1.20
(30.5)
.618
(15.7)
4
4
4
4
3
2
1
6
5
4
2
1
6
5
3
4
2
1
6
5
3
3
2
2
1
5
1
5
1
5
Dimensions in inches with metric equivalents in parentheses. Tolerance: .010"
Coil Temperature Rise - AZ2120
Percent of Nominal Coil Voltage (at 20C)
40% 60% 80% 100%
120%
140%
160%
180%
200%
Coil Temperature Rise C
160
140
120
100
80
60
40
20
0
15A
30A
25A
0A
20A
Coil Temperature Rise - AZ2110
Percent of Nominal Coil Voltage (at 20C)
40% 60% 80% 100%
120%
140%
160%
180%
200%
Coil Temperature Rise C
160
140
120
100
80
60
40
20
0
0A
15A
20A
30A
25A
Maximum Switching Capacity
10 20 30 40 60 80 100 200 300
30
20
10
8

6
5
4
3
2
1
VOLTAGE
AMPERES
DC RESISTIVE
LOAD
AC RESISTIVE
LOAD