ChipFind - документация

Электронный компонент: AZ830

Скачать:  PDF   ZIP
GENERAL DATA
Life Expectancy
Minimum operations
Mechanical
1 x 10
8
Electrical
1 x 10
5
at 2 A, 30 VDC or 1 A, 125 VAC
2 x 10
6
at 1 A, 30 VDC or .5 A, 125 VAC
(see table for additional figures)
Operate Time (typical)
3 ms at nominal coil voltage
Release Time (typical)
2 ms at nominal coil voltage
(with no coil suppression)
Capacitance
Contact to contact: 1.0 pF
Contact set to contact: 1.0 pF
Contact to coil: 2.0 pF
Bounce (typical)
At 10 mA contact current
1.5 ms at operate N.O. side
2.5 ms at operate N.C. side
Dielectric Strength
1500 Vrms contact to coil
(at sea level)
1000 Vrms between contact sets
1000 Vrms across contacts
Meets FCC Part 68.302 lightning surge
Meets FCC Part 68.304 V dielectric
Insulation Resistance
1000 megohms min. at 20C, 500 VDC,
50% RH
Dropout
Greater than 10% of nominal coil voltage
Ambient Temperature
At nominal coil voltage
Operating
Standard: -40C (-40F) to 70C (158F)
Sensitive: -40C (-40F) to 85C (185F)
Ultra-Sensitive: -40C (-40F) to 90C (194F)
Storage
All: -40C (-40F) to 115C (239F)
Vibration
0.062" DA at 1055 Hz
Shock
40 g
Enclosure
P.B.T. polyester
Terminals
Tinned copper alloy, P.C.
Max. Solder Temp.
270C (518F)
Max. Solder Time
5 seconds
Max. Solvent Temp.
80C (176F)
Max. Immersion Time
30 seconds
Weight
5 grams
COIL
Power
At Pickup Voltage
Standard coil: 200 mW
(typical)
Sensitive coil: 100 mW
Ultra-Sensitive coil: 96 mW
Max. Continuous
1.0 W at 20C (68F)
Dissipation
0.9 W at 40C (104F)
Temperature Rise
Standard: 38C (68F) at nominal coil voltage
Sensitive: 21C (38F) at nominal coil voltage
Ultra-Sensitive: 16C (29F) at nominal coil voltage
Temperature
Max. 115C (239F)
CONTACTS
Arrangement
DPDT (2 Form C)
Bifurcated crossbar contacts
Ratings
Resistive load:
Max. switched power: 60 W or 125 VA
Max. switched current: 2 A
Max. switched voltage: 250 VDC or 300 VAC
Max. carry current: 3A
Rated Load
UL
2 A at
30 VDC
1 A at 120 VAC
Material
Silver alloy, gold clad. Silver palladium, gold clad avail-
able upon request (not recommended for
current greater than 1 Amp).
Resistance
< 50 milliohms initially
AZ830
11/12/03W
POLARIZED DIP RELAY
SINGLE SIDE STABLE
FEATURES
Low profile for compact board spacing
DC coils to 48 VDC
High sensitivity, 96 mW pickup
Life expectancy to 100 million operations
High switching capacity, 60 W, 125 VA
Fits standard 16 pin IC socket
Epoxy sealed for automatic wave soldering and cleaning
Meets FCC Part 68.302 1500 V lightning surge
Meets FCC Part 68.304 1000 V dielectric
UL file E43203 (UL1950); CSA file LR 88413
NOTES
1. All values at 20C (68F).
2. Relay may pull in with less than "Must Operate" value.
3. Relay has fixed coil polarity.
4. For complete isolation between the relay's magnetic fields, it is
recommended that a .197" (5.0 mm) space be provided between
adjacent relays.
5. Relay adjustment may be affected if undue pressure is exerted
on relay case.
6. Specifications subject to change without notice.
RELAY ORDERING DATA
COIL SPECIFICATIONS
STANDARD COIL
Nominal
Max.
Coil
Must
Coil
Continuous Resistance
Operate
ORDER NUMBER*
VDC
VDC
10%
VDC
3
4.5
22.5
2.1
AZ8302C3DE
5
7.5
62.5
3.5
AZ8302C5DE
6
9.0
90
4.2
AZ8302C6DE
9
13.5
203
6.3
AZ8302C9DE
12
18.0
360
8.4
AZ8302C12DE
24
36.0
1440
16.8
AZ8302C24DE
48
72.0
5760
33.6
AZ8302C48DE
SENSITIVE COIL
3
6.4
45
2.1
AZ8302C3DSE
5
10.6
125
3.5
AZ8302C5DSE
6
12.7
180
4.2
AZ8302C6DSE
9
19.1
405
6.3
AZ8302C9DSE
12
25.5
720
8.4
AZ8302C12DSE
24
50.9
2880
16.8
AZ8302C24DSE
48
101.8
11520
33.6
AZ8302C48DSE
ULTRA-SENSITIVE COIL
3
7.3
60
2.4
AZ8302C3DSSE
5
12.3
167
4.0
AZ8302C5DSSE
6
14.7
240
4.8
AZ8302C6DSSE
9
22.0
540
7.2
AZ8302C9DSSE
12
29.4
960
9.6
AZ8302C12DSSE
24
58.8
3840
19.2
AZ8302C24DSSE
* Add suffix "R" to indicate reversed polarity.
AZ830
11/12/03W
MECHANICAL DATA
.788
(20.0)
.044
(1.1)
.138
(3.5)
.015
(0.38)
.386
(9.8)
.300
(7.61)
.200
(5.07)
.200
(5.07)
.390
(9.9)
(.024 .005)
(0.6 0.13)
TYP
.012 .005
(0.3 0.13)
TYP
PC BOARD LAYOUT
WIRING DIAGRAM
Viewed toward
terminals
Viewed toward terminals
0.1
(2.54)
.044
(1.1) REF
.044
(1.1) REF
0.03 DIA
(0.8)
(8 HOLES)
1
16
4
13
6
11
8
9
+
(WATCH FOR POLARITY)
Maximum Switching Capacity
10
20
30
40
50
60
70
80 90
10
0
200
300
400
500
600
700
800
900
1
000
.1
.2
.3
.4
.5
.6
.7
.8
.9
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
Voltage
AC Resistive Load
DC Resistive Load
Current
Dimensions in inches with metric equivalents in parentheses. Tolerance: .010"
NOTES: 1. Relays operated at nominal coil voltage.
2. Inductive load tests are at 0.7 power factor.
3. Table represents typical life figures and are not
guaranteed minimums.
TYPICAL CONTACT LIFE EXPECTANCY
NUMBER OF OPERATIONS
VOLTAGE
POWER
RESISTIVE
INDUCTIVE
LOAD
LOAD
50 mV
50 W
5x 10
7
5 x 10
7
30 VDC
60 W
5 x 10
5
15 x 10
4
30 VDC
40 W
1 x 10
6
3 x 10
5
30 VDC
20 W
3 x 10
6
1 x 10
6
60 VDC
60 W
5 x 10
5
--
60 VDC
40 W
1 x 10
6
--
60 VDC
20 W
3 x 10
6
--
30 VAC
120 VA
5 x 10
5
15 x 10
4
30 VAC
80 VA
1 x 10
6
3 x 10
5
30 VAC
40 VA
3 x 10
6
1 x 10
6
60 VAC
120 VA
5 x 10
5
15 x 10
4
60 VAC
80 VA
1 x 10
6
3 x 10
5
60 VAC
40 VA
3 x 10
6
1 x 10
6
125 VAC
125 VA
5 x 10
5
15 x 10
4
125 VAC
80 VA
1 x 10
6
3 x 10
5
125 VAC
40 VA
3 x 10
6
1 x 10
6