ChipFind - документация

Электронный компонент: Z8F082A28100KIT

Скачать:  PDF   ZIP

Document Outline

PS024705-0405
P R E L I M I N A R Y
ZiLOG Worldwide Headquarters 532 Race Street San Jose, CA 95126-3432
Telephone: 408.558.8500 Fax: 408.558
.8300 www.ZiLOG.com
Product Specification
High-Performance 8-Bit Microcontrollers
Z8 Encore! XP
F08xA
Series with eXtended
Peripherals
PS024705-0405
P R E L I M I N A R Y
This publication is subject to replacement by a later edition. To determine whether
a later edition exists, or to request copies of publications, contact:
ZiLOG Worldwide Headquarters
532 Race Street
San Jose, CA 95126
Telephone: 408.558.8500
Fax: 408.558.8300
www.ZiLOG.com
Document Disclaimer
ZiLOG is a registered trademark of ZiLOG Inc. in the United States and in other countries. All other
products and/or service names mentioned herein may be trademarks of the companies with which
they are associated.
2005 by ZiLOG, Inc. All rights reserved. Information in this publication concerning the devices,
applications, or technology described is intended to suggest possible uses and may be superseded.
ZiLOG, INC. DOES NOT ASSUME LIABILITY FOR OR PROVIDE A REPRESENTATION OF
ACCURACY OF THE INFORMATION, DEVICES, OR TECHNOLOGY DESCRIBED IN THIS
DOCUMENT. ZiLOG ALSO DOES NOT ASSUME LIABILITY FOR INTELLECTUAL PROPERTY
INFRINGEMENT RELATED IN ANY MANNER TO USE OF INFORMATION, DEVICES, OR
TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE. Devices sold by ZiLOG, Inc. are covered
by warranty and limitation of liability provisions appearing in the ZiLOG, Inc. Terms and Conditions of
Sale. ZiLOG, Inc. makes no warranty of merchantability or fitness for any purpose Except with the
express written approval of ZiLOG, use of information, devices, or technology as critical components
of life support systems is not authorized. No licenses are conveyed, implicitly or otherwise, by this
document under any intellectual property rights.
PS024705-0405
P R E L I M I N A R Y
Z8 Encore! XP
F08xA Series
Product Specification
iii
Revision History
Each instance in Table 1 reflects a change to this document from its previous revi-
sion. To see more detail, click the appropriate link in the table.
Table 1. Revision History of this Document
Date
Revision
Level
Section
Description
Page #
December
2004
02
Minor corrections to Low-Power Modes, General Purpose I/O, Analog to
Digital Converter, Comparator, Flash Option Bits, Internal Precision
Oscillator, and Electrical Characteristics Chapters.
31,39,
118,119,
120,143,
146,173,
202,203
January
2005
03
Added registered trademark designation and changed product
designation to F08xA Series
All
March
2005
04
Added clarifying information for using the UART Baud Rate Generator as
a simplified timer. Removed 2.2V
REF
. Removed 8-pin package
information throughout document.
99,2,7,8
210,211
April 2005 05
Incorporated minor changes and clarification to the Reset, GPIO,
Interrupt Controller, Electrical Characteristics, Temperature Sensor, and
Analog to Digital Converter Chapters.
1, 2, 40,
50, 51,
56, 58,
59, 61,
135,
199, 204
PS024705-0405
P R E L I M I N A R Y
Table of Contents
Z8 Encore! XP
F08xA Series
Product Specification
iv
Table of Contents
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Part Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CPU and Peripheral Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
eZ8 CPU Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General Purpose I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Flash Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Internal Precision Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Crystal Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
10-Bit Analog-to-Digital Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Analog Comparator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Temperature Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
UART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Interrupt Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Reset Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
On-Chip Debugger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Available Packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Pin Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Signal Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Pin Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Address Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Register File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Program Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Data Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
PS024705-0405
P R E L I M I N A R Y
Table of Contents
Z8 Encore! XP
F08xA Series
Product Specification
v
Flash Information Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Reset and STOP Mode Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Reset Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Reset Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Power-On Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Voltage Brown-Out Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Watch-Dog Timer Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
External Reset Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
External Reset Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
On-Chip Debugger Initiated Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
STOP Mode Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
STOP Mode Recovery Using Watch-Dog Timer Time-Out . . . . . . . . . . . . . 25
STOP Mode Recovery Using a GPIO Port Pin Transition . . . . . . . . . . . . . . 25
STOP Mode Recovery Using the External RESET Pin . . . . . . . . . . . . . . . . 26
Reset Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Low-Power Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
STOP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
HALT Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Peripheral-Level Power Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Power Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
General-Purpose I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
GPIO Port Availability By Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
GPIO Alternate Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Direct LED Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Shared Reset Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Crystal Oscillator Override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5V Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
External Clock Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
GPIO Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
GPIO Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Port AD Address Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
PS024705-0405
P R E L I M I N A R Y
Table of Contents
Z8 Encore! XP
F08xA Series
Product Specification
vi
Port AD Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Port AD Data Direction Sub-Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Port AD Alternate Function Sub-Registers . . . . . . . . . . . . . . . . . . . . . . . . 39
Port AC Input Data Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Port AD Output Data Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
LED Drive Enable Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
LED Drive Level High Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
LED Drive Level Low Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Interrupt Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Interrupt Vector Listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Master Interrupt Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Interrupt Vectors and Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Interrupt Assertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Software Interrupt Assertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Interrupt Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Interrupt Request 0 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Interrupt Request 1 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Interrupt Request 2 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
IRQ0 Enable High and Low Bit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . 53
IRQ1 Enable High and Low Bit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . 54
IRQ2 Enable High and Low Bit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Interrupt Edge Select Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Shared Interrupt Select Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Interrupt Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Timer Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Reading the Timer Count Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Timer Pin Signal Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Timer Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Timer 01 High and Low Byte Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Timer Reload High and Low Byte Registers . . . . . . . . . . . . . . . . . . . . . . . . 72
Timer 0-1 PWM High and Low Byte Registers . . . . . . . . . . . . . . . . . . . . . . 73
Timer 01 Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
PS024705-0405
P R E L I M I N A R Y
Table of Contents
Z8 Encore! XP
F08xA Series
Product Specification
vii
Watch-Dog Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Watch-Dog Timer Refresh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Watch-Dog Timer Time-Out Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Watch-Dog Timer Reload Unlock Sequence . . . . . . . . . . . . . . . . . . . . . . . . 81
Watch-Dog Timer Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . 82
Watch-Dog Timer Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Watch-Dog Timer Reload Upper, High and Low Byte Registers . . . . . . . . . 82
UART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Transmitting Data using the Polled Method . . . . . . . . . . . . . . . . . . . . . . . . 86
Transmitting Data using the Interrupt-Driven Method . . . . . . . . . . . . . . . . . 87
Receiving Data using the Polled Method . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Receiving Data using the Interrupt-Driven Method . . . . . . . . . . . . . . . . . . . 89
Clear To Send (CTS) Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
MULTIPROCESSOR (9-bit) Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
External Driver Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
UART Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
UART Baud Rate Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
UART Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
UART Transmit Data Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
UART Receive Data Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
UART Status 0 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
UART Status 1 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
UART Control 0 and Control 1 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . 98
UART Address Compare Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
UART Baud Rate High and Low Byte Registers . . . . . . . . . . . . . . . . . . . . 101
Infrared Encoder/Decoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Transmitting IrDA Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Receiving IrDA Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Infrared Encoder/Decoder Control Register Definitions . . . . . . . . . . . . . . . . . 107
PS024705-0405
P R E L I M I N A R Y
Table of Contents
Z8 Encore! XP
F08xA Series
Product Specification
viii
Analog-to-Digital Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Automatic Powerdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Single-Shot Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Continuous Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Programmable Trigger Point Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Calibration and Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Input Buffer Stage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Transimpedance Amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
ADC Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
ADC Control Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
ADC Control/Status Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
ADC Data High Byte Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
ADC Data Low Bits Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
ADC High Threshold Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
ADC Low Threshold Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Comparator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Comparator Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Temperature Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Flash Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Flash Information Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Flash Operation Timing Using the Flash Frequency Registers . . . . . . . . . 130
Flash Code Protection Against External Access . . . . . . . . . . . . . . . . . . . . 130
Flash Code Protection Against Accidental Program and Erasure . . . . . . . 130
Byte Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Page Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Mass Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Flash Controller Bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
PS024705-0405
P R E L I M I N A R Y
Table of Contents
Z8 Encore! XP
F08xA Series
Product Specification
ix
Flash Controller Behavior in Debug Mode . . . . . . . . . . . . . . . . . . . . . . . . 133
Flash Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Flash Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Flash Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Flash Page Select Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Flash Sector Protect Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Flash Frequency High and Low Byte Registers . . . . . . . . . . . . . . . . . . . . 136
Flash Option Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Option Bit Configuration By Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Option Bit Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Flash Option Bit Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . 140
Trim Bit Address Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Trim Bit Data Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Flash Option Bit Address Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Flash Program Memory Address 0000H . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Flash Program Memory Address 0001H . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Trim Bit Address Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Trim Bit Address 0000H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Trim Bit Address 0001H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
Trim Bit Address 0002H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
Trim Bit Address 0003H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Trim Bit Address 0004H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
ZiLOG Calibration Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
ADC Calibration Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Watchdog Timer Calibration Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
On-Chip Debugger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
OCD Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
DEBUG Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
OCD Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
OCD Auto-Baud Detector/Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
OCD Serial Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Breakpoints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Runtime Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
On-Chip Debugger Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
PS024705-0405
P R E L I M I N A R Y
Table of Contents
Z8 Encore! XP
F08xA Series
Product Specification
x
On-Chip Debugger Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . 158
OCD Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
OCD Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
Oscillator Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
System Clock Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Clock Failure Detection and Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
Oscillator Control Register Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Crystal Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
Crystal Oscillator Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
Oscillator Operation with an External RC Network . . . . . . . . . . . . . . . . . . . . . 167
Internal Precision Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
eZ8 CPU Instruction Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
Assembly Language Programming Introduction . . . . . . . . . . . . . . . . . . . . . . . 170
Assembly Language Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
eZ8 CPU Instruction Notation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
eZ8 CPU Instruction Classes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
eZ8 CPU Instruction Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
Opcode Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
On-Chip Peripheral AC and DC Electrical Characteristics . . . . . . . . . . . . . . . 195
General Purpose I/O Port Input Data Sample Timing . . . . . . . . . . . . . . . . 200
General Purpose I/O Port Output Timing . . . . . . . . . . . . . . . . . . . . . . . . . 202
On-Chip Debugger Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
UART Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
PS024705-0405
P R E L I M I N A R Y
Table of Contents
Z8 Encore! XP
F08xA Series
Product Specification
xi
Customer Feedback Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
PS024705-0405
P R E L I M I N A R Y
List of Figures
Z8 Encore! XP
F08xA Series
Product Specification
xii
List of Figures
Figure 1. Z8 Encore! XP" F08xA Series Block Diagram . . . . . . . . . . . . . . . . . . . 3
Figure 2. Z8 Encore! XP" F08xA Series in 20-Pin SOIC, SSOP or PDIP Package
8
Figure 3. Z8 Encore! XP" F08xA Series in 28-Pin SOIC, SSOP or PDIP Package
8
Figure 4. Power-On Reset Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 5. Voltage Brown-Out Reset Operation . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 6. GPIO Port Pin Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 7. Interrupt Controller Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 8. Timer Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Figure 9. UART Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Figure 10. UART Asynchronous Data Format without Parity . . . . . . . . . . . . . . 86
Figure 11. UART Asynchronous Data Format with Parity . . . . . . . . . . . . . . . . . 86
Figure 12. UART Asynchronous MULTIPROCESSOR Mode Data Format . . . 90
Figure 13. UART Driver Enable Signal Timing (shown with 1 Stop Bit and Parity)
92
Figure 14. UART Receiver Interrupt Service Routine Flow . . . . . . . . . . . . . . . . 94
Figure 15. Infrared Data Communication System Block Diagram . . . . . . . . . 104
Figure 16. Infrared Data Transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Figure 17. IrDA Data Reception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Figure 18. Analog-to-Digital Converter Block Diagram . . . . . . . . . . . . . . . . . . 109
Figure 19. Flash Memory Arrangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Figure 20. Flash Controller Operation Flow Chart . . . . . . . . . . . . . . . . . . . . . . 129
Figure 21. On-Chip Debugger Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . 148
Figure 22. Interfacing the On-Chip Debugger's DBG Pin with an RS-232 Interface
(1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Figure 23. Interfacing the On-Chip Debugger's DBG Pin with an RS-232 Interface
(2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Figure 24. OCD Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
PS024705-0405
P R E L I M I N A R Y
List of Figures
Z8 Encore! XP
F08xA Series
Product Specification
xiii
Figure 25. Recommended 20 MHz Crystal Oscillator Configuration . . . . . . . . 166
Figure 26. Connecting the On-Chip Oscillator to an External RC Network . . . 167
Figure 27. Typical RC Oscillator Frequency as a Function of the External Capaci-
tance with a 45KOhm Resistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
Figure 28. Opcode Map Cell Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Figure 29. First Opcode Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Figure 30. Second Opcode Map after 1FH . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
Figure 31. ICC Versus System Clock Frequency . . . . . . . . . . . . . . . . . . . . . . 193
Figure 32. Port Input Sample Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
Figure 33. GPIO Port Output Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Figure 34. On-Chip Debugger Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
Figure 35. UART Timing With CTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Figure 36. UART Timing Without CTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Figure 37. 20-Pin Plastic Dual Inline Package (PDIP) . . . . . . . . . . . . . . . . . . 206
Figure 38. 20-Pin Small Outline Integrated Circuit Package (SOIC) . . . . . . . . 207
Figure 39. 20-Pin Small Shrink Outline Package (SSOP) . . . . . . . . . . . . . . . . 208
Figure 40. 28-Pin Plastic Dual Inline Package (PDIP) . . . . . . . . . . . . . . . . . . 209
Figure 41. 28-Pin Small Outline Integrated Circuit Package (SOIC) . . . . . . . . 210
Figure 42. 28-Pin Small Shrink Outline Package (SSOP) . . . . . . . . . . . . . . . . 211
PS024705-0405
P R E L I M I N A R Y
List of Tables
Z8 Encore! XP
F08xA Series
Product Specification
xiv
List of Tables
Table 1. Revision History of this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Table 2. Z8 Encore! XP" F08xA Series Family Part Selection Guide. . . . . . . . . . 2
Table 3. Z8 Encore! XP" F08xA Series Package Options . . . . . . . . . . . . . . . . . . 7
Table 4. Signal Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 5. Pin Characteristics (20- and 28-pin Devices) . . . . . . . . . . . . . . . . . . . . 11
Table 6. Z8 Encore! XP" F08xA Series Program Memory Maps . . . . . . . . . . . . 13
Table 7. Z8 Encore! XP" F08xA Series Flash Memory Information Area Map. . 14
Table 8. Register File Address Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 9. Reset and STOP Mode Recovery Characteristics and Latency. . . . . . 19
Table 10. Reset Sources and Resulting Reset Type . . . . . . . . . . . . . . . . . . . . . 21
Table 11. STOP Mode Recovery Sources and Resulting Action . . . . . . . . . . . . 25
Table 12. Reset Status Register (RSTSTAT). . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 13. Power Control Register 0 (PWRCTL0). . . . . . . . . . . . . . . . . . . . . . . . 30
Table 14. Port Availability by Device and Package Type . . . . . . . . . . . . . . . . . . 31
Table 15. Port Alternate Function Mapping (20/28-Pin Parts) . . . . . . . . . . . . . . 34
Table 16. GPIO Port Registers and Sub-Registers . . . . . . . . . . . . . . . . . . . . . . 37
Table 17. Port AD GPIO Address Registers (PxADDR). . . . . . . . . . . . . . . . . . 37
Table 18. Port AD Control Registers (PxCTL) . . . . . . . . . . . . . . . . . . . . . . . . . 38
Table 19. Port AD Data Direction Sub-Registers (PxDD) . . . . . . . . . . . . . . . . 39
Table 20. Port AD Alternate Function Sub-Registers (PxAF). . . . . . . . . . . . . . 39
Table 21. Port AD Output Control Sub-Registers (PxOC) . . . . . . . . . . . . . . . . 40
Table 22. Port AD High Drive Enable Sub-Registers (PxHDE) . . . . . . . . . . . . 40
Table 23. Port AD STOP Mode Recovery Source Enable Sub-Registers (Px-
SMRE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 24. Port AD Pull-Up Enable Sub-Registers (PxPUE) . . . . . . . . . . . . . . . 41
Table 25. Port AD Alternate Function Set 1 Sub-Registers (PxAFS1). . . . . . . 42
Table 26. Port AD Alternate Function Set 2 Sub-Registers (PxAFS2). . . . . . . 42
Table 27. Port AC Input Data Registers (PxIN) . . . . . . . . . . . . . . . . . . . . . . . . 43
PS024705-0405
P R E L I M I N A R Y
List of Tables
Z8 Encore! XP
F08xA Series
Product Specification
xv
Table 28. Port AD Output Data Register (PxOUT). . . . . . . . . . . . . . . . . . . . . . 43
Table 29. LED Drive Enable (LEDEN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Table 30. LED Drive Level High Register (LEDLVLH) . . . . . . . . . . . . . . . . . . . . 44
Table 31. LED Drive Level Low Register (LEDLVLL). . . . . . . . . . . . . . . . . . . . . 45
Table 32. Trap and Interrupt Vectors in Order of Priority . . . . . . . . . . . . . . . . . . 47
Table 33. Interrupt Request 0 Register (IRQ0) . . . . . . . . . . . . . . . . . . . . . . . . . 51
Table 34. Interrupt Request 1 Register (IRQ1) . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 35. Interrupt Request 2 Register (IRQ2) . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 36. IRQ0 Enable and Priority Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Table 37. IRQ0 Enable High Bit Register (IRQ0ENH) . . . . . . . . . . . . . . . . . . . . 53
Table 38. IRQ0 Enable Low Bit Register (IRQ0ENL). . . . . . . . . . . . . . . . . . . . . 53
Table 39. IRQ1 Enable and Priority Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Table 40. IRQ1 Enable High Bit Register (IRQ1ENH) . . . . . . . . . . . . . . . . . . . . 54
Table 41. IRQ1 Enable Low Bit Register (IRQ1ENL). . . . . . . . . . . . . . . . . . . . . 55
Table 42. IRQ2 Enable and Priority Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Table 43. IRQ2 Enable High Bit Register (IRQ2ENH) . . . . . . . . . . . . . . . . . . . . 55
Table 44. IRQ2 Enable Low Bit Register (IRQ2ENL). . . . . . . . . . . . . . . . . . . . . 56
Table 45. Interrupt Edge Select Register (IRQES). . . . . . . . . . . . . . . . . . . . . . . 56
Table 46. Shared Interrupt Select Register (IRQSS) . . . . . . . . . . . . . . . . . . . . . 57
Table 47. Interrupt Control Register (IRQCTL) . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 48. Timer 01 High Byte Register (TxH) . . . . . . . . . . . . . . . . . . . . . . . . . 72
Table 49. Timer 01 Low Byte Register (TxL) . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Table 50. Timer 01 Reload High Byte Register (TxRH) . . . . . . . . . . . . . . . . . . 73
Table 51. Timer 01 Reload Low Byte Register (TxRL). . . . . . . . . . . . . . . . . . . 73
Table 52. Timer 01 PWM High Byte Register (TxPWMH) . . . . . . . . . . . . . . . . 73
Table 53. Timer 01 Control Register 0 (TxCTL0) . . . . . . . . . . . . . . . . . . . . . . . 74
Table 54. Timer 01 PWM Low Byte Register (TxPWML) . . . . . . . . . . . . . . . . . 74
Table 55. Timer 01 Control Register 1 (TxCTL1) . . . . . . . . . . . . . . . . . . . . . . . 75
Table 56. Watch-Dog Timer Approximate Time-Out Delays . . . . . . . . . . . . . . . 80
Table 57. Watch-Dog Timer Control Register (WDTCTL) . . . . . . . . . . . . . . . . . 82
PS024705-0405
P R E L I M I N A R Y
List of Tables
Z8 Encore! XP
F08xA Series
Product Specification
xvi
Table 58. Watch-Dog Timer Reload Upper Byte Register (WDTU) . . . . . . . . . . 83
Table 59. Watch-Dog Timer Reload High Byte Register (WDTH) . . . . . . . . . . . 83
Table 60. Watch-Dog Timer Reload Low Byte Register (WDTL) . . . . . . . . . . . . 83
Table 61. UART Transmit Data Register (U0TXD) . . . . . . . . . . . . . . . . . . . . . . 95
Table 62. UART Receive Data Register (U0RXD) . . . . . . . . . . . . . . . . . . . . . . . 96
Table 63. UART Status 0 Register (U0STAT0) . . . . . . . . . . . . . . . . . . . . . . . . . 96
Table 64. UART Status 1 Register (U0STAT1) . . . . . . . . . . . . . . . . . . . . . . . . . 97
Table 65. UART Control 0 Register (U0CTL0). . . . . . . . . . . . . . . . . . . . . . . . . . 98
Table 66. UART Control 1 Register (U0CTL1). . . . . . . . . . . . . . . . . . . . . . . . . . 99
Table 67. UART Address Compare Register (U0ADDR) . . . . . . . . . . . . . . . . . 101
Table 68. UART Baud Rate High Byte Register (U0BRH) . . . . . . . . . . . . . . . . 101
Table 69. UART Baud Rate Low Byte Register (U0BRL) . . . . . . . . . . . . . . . . 101
Table 70. UART Baud Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Table 71. ADC Control Register 0 (ADCCTL0) . . . . . . . . . . . . . . . . . . . . . . . . 117
Table 72. ADC Control/Status Register 1 (ADCCTL1). . . . . . . . . . . . . . . . . . . 119
Table 73. ADC Data High Byte Register (ADCD_H) . . . . . . . . . . . . . . . . . . . . 120
Table 74. ADC Data Low Bits Register (ADCD_L). . . . . . . . . . . . . . . . . . . . . . 120
Table 75. ADC High Threshold High Byte (ADCTH) . . . . . . . . . . . . . . . . . . . . 121
Table 76. ADC Low Threshold High Byte (ADCTL) . . . . . . . . . . . . . . . . . . . . . 121
Table 77. Comparator Control Register (CMP0) . . . . . . . . . . . . . . . . . . . . . . . 123
Table 78. Z8 Encore! XP" F08xA Series Flash Memory Configurations . . . . . 126
Table 79. Flash Code Protection Using the Flash Option Bits . . . . . . . . . . . . . 131
Table 80. Flash Control Register (FCTL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Table 81. Flash Status Register (FSTAT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Table 82. Flash Page Select Register (FPS) . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Table 83. Flash Sector Protect Register (FPROT). . . . . . . . . . . . . . . . . . . . . . 136
Table 84. Flash Frequency High Byte Register (FFREQH) . . . . . . . . . . . . . . . 137
Table 85. Flash Frequency Low Byte Register (FFREQL). . . . . . . . . . . . . . . . 137
Table 86. Trim Bit Address Register (TRMADR) . . . . . . . . . . . . . . . . . . . . . . . 140
Table 87. Trim Bit Data Register (TRMDR) . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
PS024705-0405
P R E L I M I N A R Y
List of Tables
Z8 Encore! XP
F08xA Series
Product Specification
xvii
Table 88. Flash Option Bits at Program Memory Address 0000H . . . . . . . . . . 141
Table 89. Flash Options Bits at Program Memory Address 0001H . . . . . . . . . 142
Table 90. Trim Options Bits at Address 0000H (TTEMP0) . . . . . . . . . . . . . . . 142
Table 91. Trim Option Bits at 0001H (TTEMP1) . . . . . . . . . . . . . . . . . . . . . . . 143
Table 92. Trim Option Bits at 0002H (TIPO) . . . . . . . . . . . . . . . . . . . . . . . . . . 143
Table 93. Trim Option Bits at Address 0003H (TLVD) . . . . . . . . . . . . . . . . . . . 144
Table 94. Trim Option Bits at 0004H (TBG) . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Table 95. ADC Calibration Bits at 0060H-007DH. . . . . . . . . . . . . . . . . . . . . . . 145
Table 96. ADC Calibration Data Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Table 97. Watchdog Calibration High Byte at 007EH (WDTCALH) . . . . . . . . . 147
Table 98. Watchdog Calibration Low Byte at 007FH (WDTCALL). . . . . . . . . . 147
Table 99. OCD Baud-Rate Limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Table 100. OCD Control Register (OCDCTL) . . . . . . . . . . . . . . . . . . . . . . . . . 158
Table 101. OCD Status Register (OCDSTAT) . . . . . . . . . . . . . . . . . . . . . . . . . 159
Table 102. Oscillator Configuration and Selection . . . . . . . . . . . . . . . . . . . . . . 161
Table 103. Oscillator Control Register (OSCCTL) . . . . . . . . . . . . . . . . . . . . . . 163
Table 104. Recommended Crystal Oscillator Specifications. . . . . . . . . . . . . . 166
Table 105. Assembly Language Syntax Example 1. . . . . . . . . . . . . . . . . . . . . 171
Table 106. Assembly Language Syntax Example 2. . . . . . . . . . . . . . . . . . . . . 171
Table 107. Notational Shorthand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
Table 108. Additional Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
Table 109. Arithmetic Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
Table 110. Bit Manipulation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Table 111. Block Transfer Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Table 112. CPU Control Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Table 113. Logical Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
Table 114. Load Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
Table 115. Program Control Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Table 116. Rotate and Shift Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Table 117. eZ8 CPU Instruction Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
PS024705-0405
P R E L I M I N A R Y
List of Tables
Z8 Encore! XP
F08xA Series
Product Specification
xviii
Table 118. Opcode Map Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Table 119. Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Table 120. DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
Table 121. AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Table 122. Power-On Reset and Voltage Brown-Out Electrical Characteristics and
Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Table 123. Flash Memory Electrical Characteristics and Timing . . . . . . . . . . . 196
Table 124. Watch-Dog Timer Electrical Characteristics and Timing . . . . . . . . 196
Table 125. Analog-to-Digital Converter Electrical Characteristics and Timing. 197
Table 126. Comparator Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . 199
Table 127. Temperature Sensor Electrical Characteristics . . . . . . . . . . . . . . . 200
Table 128. GPIO Port Input Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
Table 129. GPIO Port Output Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Table 130. On-Chip Debugger Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
Table 131. UART Timing With CTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Table 132. UART Timing Without CTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
PS024705-0405
P R E L I M I N A R Y Overview
Z8 Encore! XP
F08xA Series
Product Specification
1
Overview
The Z8 Encore!
MCU family of products are the first in a line of ZiLOG
microcontrol-
ler products based upon the 8-bit eZ8 CPU. The Z8 Encore! XP
F08xA Series products,
expand upon ZiLOG's extensive line of 8-bit microcontrollers. The Flash in-circuit pro-
gramming capability allows for faster development time and program changes in the field.
The new eZ8 CPU is upward compatible with existing Z8
instructions. The rich periph-
eral set of the Z8 Encore! XP
F08xA Series makes it suitable for a variety of applications
including motor control, security systems, home appliances, personal electronic devices,
and sensors.
Features
20MHz eZ8 CPU
8KB Flash memory with in-circuit programming capability
1KB register RAM
17 to 25 I/O pins depending upon package
Internal Precision Oscillator
External crystal oscillator
Full-duplex UART
Infrared Data Association (IrDA)-compliant infrared encoder/decoders, integrated with
UART
Two enhanced 16-bit timers with capture, compare, and PWM capability
Watch-Dog Timer (WDT) with dedicated internal RC oscillator
On-Chip Debugger
Optional 8-channel, 10-bit Analog-to-Digital Converter (ADC)
On-Chip temperature sensor
On-Chip analog comparator
On-Chip current sense amplifier
Up to 20 vectored interrupts
Voltage Brown-out Protection (VBO)
Power-On Reset (POR)
2.7 to 3.6V operating voltage
PS024705-0405
P R E L I M I N A R Y Overview
Z8 Encore! XP
F08xA Series
Product Specification
2
Up to thirteen 5V-tolerant input pins
20- and 28-pin packages
0 to +70C and -40 to +105C for operating temperature ranges
Part Selection Guide
Table 1 identifies the basic features and package styles available for each device within the
Z8 Encore! XP
F08xA Series product line.
Block Diagram
Figure 1 illustrates the block diagram of the architecture of the Z8 Encore! XP
F08xA
Series devices
.
Table 1. Z8 Encore! XP
F08xA Series Family Part Selection Guide
Part
Number
Flash
(KB)
RAM
(B)
I/O
ADC
Inputs
Packages
Z8F082A
8
1024
1723
78
20- and 28-pins
Z8F081A
8
1024
1725
0
20- and 28-pins
PS024705-0405
P R E L I M I N A R Y Overview
Z8 Encore! XP
F08xA Series
Product Specification
3
Figure 1. Z8 Encore! XP
F08xA Series Block Diagram
GPIO
IrDA
UART
Timers
ADC
Flash
Flash
Controller
RAM
RAM
Controller
Memory
Interrupt
Controller
On-Chip
Debugger
eZ8
CPU
WDT
POR/VBO
& Reset
Controller
XTAL/RC
Oscillator
Register Bus
Memory Busses
System
Clock
Comparator
Temperature
Sensor
Low Power
RC Oscillator
Internal
Oscillator
Control
Oscillator
Precision
PS024705-0405
P R E L I M I N A R Y Overview
Z8 Encore! XP
F08xA Series
Product Specification
4
CPU and Peripheral Overview
eZ8 CPU Features
The eZ8 CPU, ZiLOG
's latest 8-bit Central Processing Unit (CPU), meets the continuing
demand for faster and more code-efficient microcontrollers. The eZ8 CPU executes a
superset of the original Z8
instruction set. The eZ8 CPU features include:
Direct register-to-register architecture allows each register to function as an
accumulator, improving execution time and decreasing the required program memory
Software stack allows much greater depth in subroutine calls and interrupts than
hardware stacks
Compatible with existing Z8
code
Expanded internal Register File allows access of up to 4KB
New instructions improve execution efficiency for code developed using higher-level
programming languages, including C
Pipelined instruction fetch and execution
New instructions for improved performance including BIT, BSWAP, BTJ, CPC, LDC,
LDCI, LEA, MULT, and SRL
New instructions support 12-bit linear addressing of the Register File
Up to 10 MIPS operation
C-Compiler friendly
2 to 9 clock cycles per instruction
For more information regarding the eZ8 CPU, refer to the eZ8 CPU User Manual avail-
able for download at
www.zilog.com
.
General Purpose I/O
The Z8 Encore! XP
F08xA Series features 6 to 25 port pins (Ports AD) for general pur-
pose I/O (GPIO). The number of GPIO pins available is a function of package. Each pin is
individually programmable.
Flash Controller
The Flash Controller programs and erases Flash memory. The Flash Controller supports
protection against accidental program and erasure.
PS024705-0405
P R E L I M I N A R Y Overview
Z8 Encore! XP
F08xA Series
Product Specification
5
Internal Precision Oscillator
The Internal Precision Oscillator (IPO) is a trimmable clock source that requires no exter-
nal components.
Crystal Oscillator
The crystal oscillator circuit provides highly accurate clock frequencies with the use of an
external crystal, ceramic resonator or RC network.
10-Bit Analog-to-Digital Converter
The optional Analog-to-Digital Converter (ADC) converts an analog input signal to a 10-
bit binary number. The ADC accepts inputs from 8 different analog input pins in both sin-
gle-ended and differential modes.
Analog Comparator
The analog comparator compares the signal at an input pin with either an internal pro-
grammable voltage reference or a second input pin. The comparator output can be used to
drive either an output pin or to generate an interrupt.
Temperature Sensor
The Temperature Sensor produces an analog output proportional to the device tempera-
ture. This signal can be sent to either the ADC or the analog comparator.
UART
The UART is full-duplex and capable of handling asynchronous data transfers. The UART
supports 8- and 9-bit data modes and selectable parity. The UART also supports multi-
drop address processing in hardware.
Timers
Two enhanced 16-bit reloadable timers can be used for timing/counting events or for
motor control operations. These timers provide a 16-bit programmable reload counter and
operate in One-Shot, Continuous, Gated, Capture, Capture Restart, Compare, Capture and
Compare, PWM Single Output and PWM Dual Output modes.
PS024705-0405
P R E L I M I N A R Y Overview
Z8 Encore! XP
F08xA Series
Product Specification
6
Interrupt Controller
The Z8 Encore! XP
F08xA Series products support up to 20 interrupts. These interrupts
consist of 8 internal peripheral interrupts and 12 general-purpose I/O pin interrupt sources.
The interrupts have 3 levels of programmable interrupt priority.
Reset Controller
The Z8 Encore! XP
F08xA Series products can be reset using the RESET pin, power-on
reset, Watch-Dog Timer (WDT) time-out, STOP mode exit, or Voltage Brown-Out (VBO)
warning signal. The RESET pin is bi-directional, meaning it functions as reset source as
well as a reset indicator.
On-Chip Debugger
The Z8 Encore! XP
F08xA Series products feature an integrated On-Chip Debugger
(OCD). The OCD provides a rich set of debugging capabilities, such as reading and writ-
ing registers, programming Flash memory, setting breakpoints and executing code. A sin-
gle-pin interface provides communication to the OCD.
PS024705-0405
P R E L I M I N A R Y Pin
Description
Z8 Encore! XP
F08xA Series
Product Specification
7
Pin Description
Overview
The Z8 Encore! XP
F08xA Series products are available in a variety of packages styles
and pin configurations. This chapter describes the signals and available pin configurations
for each of the package styles. For information regarding the physical package specifica-
tions, refer to the chapter
"Packaging" on page 206
.
Available Packages
Table 2 identifies the package styles that are available for each device in the Z8 Encore!
XP
F08xA Series product line.
Pin Configurations
Figures 2 and 4 illustrate the pin configurations for all of the packages available in the Z8
Encore! XP
F08xA Series. Refer to Table 3 for a description of the signals. The analog
input alternate functions (ANAx) are not available on the Z8F081A devices. The analog
supply pins (AV
DD
and AV
SS
) are also not available on these parts, and are replaced by
PB6 and PB7.
At reset, all Port A, B and C pins default to an input state. In addition, any alternate func-
tionality is not enabled, so the pins function as general purpose input ports until pro-
grammed otherwise. At powerup, the Port D0 pin defaults to the RESET alternate
function.
The pin configurations listed are preliminary and subject to change based on manufactur-
ing limitations.
Table 2. Z8 Encore! XP
F08xA Series Package Options
Part Number
ADC
20-pin
PDIP
20-pin
SOIC
20-pin
SSOP
28-pin
PDIP
28-pin
SOIC
28-pin
SSOP
Z8F082A
Yes
X
X
X
X
X
X
Z8F081A
No
X
X
X
X
X
X
PS024705-0405
P R E L I M I N A R Y Pin
Description
Z8 Encore! XP
F08xA Series
Product Specification
8
Figure 2.Z8 Encore! XP
F08xA
Series in 20-Pin SOIC, SSOP or PDIP Package
Figure 3.
Z
8 Encore! XP
F08xA Series in 28-Pin SOIC, SSOP or PDIP Package
Signal Descriptions
Table 3 describes the Z8 Encore! XP
F08xA Series signals. Refer to the section
"Pin
Configurations" on page 7
to determine the signals available for the specific package
styles.
PB0/ANA0/AMPOUT
PC3/COUT/LED
PC2/ANA6/LED
PC1/ANA5/CINN/LED
PC0/ANA4/CINP/LED
DBG
RESET/PD0
PA7/T1OUT
PA6/T1IN/T1OUT
PB1/ANA1/AMPINN
PB2/ANA2/AMPINP
PB3/CLKIN/ANA3
VDD
PA0/T0IN/T0OUT/XIN
PA1/T0OUT/XOUT
VSS
PA2/DE0
1
PA5/TXD0
PA3/CTS0
5
10
PA4/RXD0
2
3
4
6
7
8
9
20
16
11
19
18
17
15
14
13
12
PB1/ANA1/AMPINN
PB0/ANA0/AMPOUT
PC3/COUT/LED
PC2/ANA6/LED
PC1/ANA5/CINN/LED
PC0/ANA4/CINP/LED
DBG
RESET/PD0
PC7/LED
PB2/ANA2/AMPINP
PB3/CLKIN/ANA3
PB4/ANA7
PB5/VREF
(PB6) AVDD
VDD
PA0/T0IN/T0OUT/XIN
PA1/T0OUT/XOUT
1
PC6/LED
VSS
5
10
(PB7) AVSS
PA2/DE0
PA3/CTS0
PA4/RXD0
14
PA5/TXD0
2
3
4
6
7
8
9
11
12
13
PC5/LED
PC4/LED
PA7/T1OUT
PA6/T1IN/T1OUT
28
24
19
15
27
26
25
23
22
21
20
18
17
16
PS024705-0405
P R E L I M I N A R Y Pin
Description
Z8 Encore! XP
F08xA Series
Product Specification
9
Table 3. Signal Descriptions
Signal Mnemonic
I/O
Description
General-Purpose I/O Ports AD
PA[7:0]
I/O
Port A. These pins are used for general-purpose I/O.
PB[7:0]
I/O
Port B. These pins are used for general-purpose I/O. PB6 and PB7 are
available only in those devices without an ADC.
PC[7:0]
I/O
Port C. These pins are used for general-purpose I/O.
PD[0]
I/O
Port D. This pin is used for general-purpose output only.
Note: PB6 and PB7 are only available in 28-pin packages without ADC. In 28-pin packages with ADC,
they are replaced by AV
DD
and AV
SS
.
UART Controllers
TXD0
O
Transmit Data. This signal is the transmit output from the UART and IrDA.
RXD0
I
Receive Data. This signal is the receive input for the UART and IrDA.
CTS0
I
Clear To Send. This signal is the flow control input for the UART.
DE
O
Driver Enable. This signal allows automatic control of external RS-485
drivers. This signal is approximately the inverse of the TXE (Transmit
Empty) bit in the UART Status 0 register. The DE signal may be used to
ensure the external RS-485 driver is enabled when data is transmitted by
the UART.
Timers
T0OUT/T1OUT
O
Timer Output 01. These signals are output from the timers.
T0OUT/T1OUT
O
Timer Complement Output 01. These signals are output from the timers
in PWM Dual Output mode.
T0IN/T1IN
I
Timer Input 01. These signals are used as the capture, gating and
counter inputs. The T0IN signal is multiplexed T0OUT signals.
Comparator
CINP/CINN
I
Comparator Inputs. These signals are the positive and negative inputs to
the comparator.
COUT
O
Comparator Output. This is the output of the comparator.
Analog
ANA[7:0]
I
Analog Port. These signals are used as inputs to the analog-to-digital
converter (ADC). The ANA0, ANA1 and ANA2 pins can also access the
inputs and output of the integrated transimpedance amplifier.
VREF
I/O
Analog-to-digital converter reference voltage input.
PS024705-0405
P R E L I M I N A R Y Pin
Description
Z8 Encore! XP
F08xA Series
Product Specification
10
Transimpedance Amplifier
AMPINP/AMPINN
I
Transimpedance amplifier inputs. If enabled, these pins drive the positive
and negative amplifier inputs respectively.
AMPOUT
O
Transimpedance amplifier output. If enabled, this pin is driven by the on-
chip transimpedance amplifier.
Oscillators
XIN
I
External Crystal Input. This is the input pin to the crystal oscillator. A
crystal can be connected between it and the
XOUT
pin to form the
oscillator. In addition, this pin is used with external RC networks or external
clock drivers to provide the system clock.
XOUT
O
External Crystal Output. This pin is the output of the crystal oscillator. A
crystal can be connected between it and the
XIN
pin to form the oscillator.
Clock Input
CLKIN
I
Clock Input Signal. This pin may be used to input a TTL-level signal to be
used as the system clock.
LED Drivers
LED
O
Direct LED drive capability. All port C pins have the capability to drive an
LED without any other external components. These pins have
programmable drive strengths set by the GPIO block.
On-Chip Debugger
DBG
I/O
Debug. This signal is the control and data input and output to and from the
On-Chip Debugger.
The DBG pin is open-drain and requires an external pull-up resistor to
ensure proper operation.
Reset
RESET
I/O
RESET. Generates a Reset when asserted (driven Low). Also serves as a
reset indicator; the Z8 Encore! XP
forces this pin low when in reset. This
pin is open-drain and features an enabled internal pull-up resistor.
Power Supply
V
DD
I
Digital Power Supply.
AV
DD
I
Analog Power Supply.
Table 3. Signal Descriptions (Continued)
Signal Mnemonic
I/O
Description
Caution:
PS024705-0405
P R E L I M I N A R Y Pin
Description
Z8 Encore! XP
F08xA Series
Product Specification
11
Pin Characteristics
Table 4 provides detailed information about the characteristics for each pin available on
the Z8 Encore! XP
F08xA Series 20- and 28-pin devices. Data in Table 4 is sorted alpha-
betically by the pin symbol mnemonic.
PB6 and PB7 are available only in those devices without ADC.
V
SS
I
Digital Ground.
AV
SS
I
Analog Ground.
Note: The AV
DD
and AV
SS
signals are available only in 28-pin packages with ADC. They are replaced by
PB6 and PB7 on 28-pin packages without ADC.
Table 4. Pin Characteristics (20- and 28-pin Devices)
Symbol
Mnemonic Direction
Reset
Direction
Active Low
or
Active High
Tristate
Output
Internal Pull-
up
or Pull-down
Schmitt
Trigger
Input
Open Drain
Output
5V
Tolerance
AVDD
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
AVSS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
NA
DBG
I/O
I
N/A
Yes
No
Yes
Yes
Yes
PA[7:0]
I/O
I
N/A
Yes
Programmable
Pull-up
Yes
Yes,
Programmable
PA[7:2]
only
PB[7:0]
I/O
I
N/A
Yes
Programmable
Pull-up
Yes
Yes,
Programmable
PB[7:6]
only
PC[7:0]
I/O
I
N/A
Yes
Programmable
Pull-up
Yes
Yes,
Programmable
PC[7:3]
only
RESET/
PD0
I/O
I/O
(defaults to
RESET)
Low (in
Reset mode)
Yes (PD0
only)
programmable
for PD0;
always on for
RESET
Yes
programmable
for PD0; always
on for RESET
Yes
VDD
N/A
N/A
N/A
N/A
N/A
N/A
VSS
N/A
N/A
N/A
N/A
N/A
N/A
Table 3. Signal Descriptions (Continued)
Signal Mnemonic
I/O
Description
Note:
PS024705-0405
P R E L I M I N A R Y Address
Space
Z8 Encore! XP
F08xA Series
Product Specification
12
Address Space
Overview
The eZ8 CPU can access three distinct address spaces:
The Register File contains addresses for the general-purpose registers and the eZ8 CPU,
peripheral, and general-purpose I/O port control registers.
The Program Memory contains addresses for all memory locations having executable
code and/or data.
The Data Memory contains addresses for all memory locations that contain data only.
These three address spaces are covered briefly in the following subsections. For more
detailed information regarding the eZ8 CPU and its address space, refer to the eZ8 CPU
User Manual
available for download at
www.zilog.com
.
Register File
The Register File address space in the Z8 Encore!
MCU is 8KB (8192 bytes). The Regis-
ter File is composed of two sections: control registers and general-purpose registers. When
instructions are executed, registers defined as sources are read, and registers defined as
destinations are written. The architecture of the eZ8 CPU allows all general-purpose regis-
ters to function as accumulators, address pointers, index registers, stack areas, or scratch
pad memory.
The upper 256 bytes of the 8KB Register File address space are reserved for control of the
eZ8 CPU, the on-chip peripherals, and the I/O ports. These registers are located at
addresses from
F00H
to
FFFH
. Some of the addresses within the 256B control register sec-
tion are reserved (unavailable). Reading from a reserved Register File address returns an
undefined value. Writing to reserved Register File addresses is not recommended and can
produce unpredictable results.
The on-chip RAM always begins at address
000H
in the Register File address space. The
Z8 Encore! XP
F08xA Series devices contain 1KB of on-chip RAM. Reading from Reg-
ister File addresses outside the available RAM addresses (and not within the control regis-
ter address space) returns an undefined value. Writing to these Register File addresses
produces no effect.
PS024705-0405
P R E L I M I N A R Y Address
Space
Z8 Encore! XP
F08xA Series
Product Specification
13
Program Memory
The eZ8 CPU supports 64KB of Program Memory address space. The Z8 Encore! XP
F08xA Series devices contain 8KB of on-chip Flash memory in the Program Memory
address space, depending on the device. Reading from Program Memory addresses out-
side the available Flash memory addresses returns
FFH
. Writing to these unimplemented
Program Memory addresses produces no effect. Table 5 describes the Program Memory
Maps for the Z8 Encore! XP
F08xA Series products.
Data Memory
The Z8 Encore! XP
F08xA Series does not use the eZ8 CPU's 64KB Data Memory
address space.
Flash Information Area
Table 6 describes the Z8 Encore! XP
F08xA Series Flash Information Area. This 128B
Information Area is accessed by setting bit 7 of the Flash Page Select Register to 1. When
access is enabled, the Flash Information Area is mapped into the Program Memory and
overlays the 128 bytes at addresses
FE00H
to
FF7FH
. When the Information Area access is
enabled, all reads from these Program Memory addresses return the Information Area data
rather than the Program Memory data. Access to the Flash Information Area is read-only.
Table 5. Z8 Encore! XP
F08xA
Series Program Memory Maps
Program Memory Address (Hex)
Function
Z8F082A and Z8F081A Products
00000001
Flash Option Bits
00020003
Reset Vector
00040005
WDT Interrupt Vector
00060007
Illegal Instruction Trap
00080037
Interrupt Vectors*
003E1FFF
Program Memory
* See
Table 31 on page 47
for a list of the interrupt vectors.
PS024705-0405
P R E L I M I N A R Y Address
Space
Z8 Encore! XP
F08xA Series
Product Specification
14
Table 6. Z8 Encore! XP
F08xA Series Flash Memory Information Area Map
Program Memory Address (Hex) Function
FE00FE3F
ZiLOG Option Bits
FE40FE53
Part Number
20-character ASCII alphanumeric code
Left justified and filled with FH
FE54FE5F
Reserved
FE60FE7F
ZiLOG Calibration Data
FE80FFFF
Reserved
PS024705-0405
P R E L I M I N A R Y Register
Map
Z8 Encore! XP
F08xA Series
Product Specification
15
Register Map
Table 7 provides the address map for the Register File of the Z8 Encore! XP
F08xA
Series devices. Not all devices and package styles in the Z8 Encore! XP
F08xA Series
support the ADC, or all of the GPIO Ports. Consider registers for unimplemented periph-
erals as Reserved.
Table 7. Register File Address Map
Address (Hex)
Register Description
Mnemonic
Reset (Hex)
Page #
General Purpose RAM
Z8F082A/Z8F081A Devices
0003FF
General-Purpose Register File RAM
--
XX
400EFF
Reserved
--
XX
Timer 0
F00
Timer 0 High Byte
T0H
00
72
F01
Timer 0 Low Byte
T0L
01
72
F02
Timer 0 Reload High Byte
T0RH
FF
73
F03
Timer 0 Reload Low Byte
T0RL
FF
73
F04
Timer 0 PWM High Byte
T0PWMH
00
73
F05
Timer 0 PWM Low Byte
T0PWML
00
74
F06
Timer 0 Control 0
T0CTL0
00
74
F07
Timer 0 Control 1
T0CTL1
00
75
Timer 1
F08
Timer 1 High Byte
T1H
00
72
F09
Timer 1 Low Byte
T1L
01
72
F0A
Timer 1 Reload High Byte
T1RH
FF
73
F0B
Timer 1 Reload Low Byte
T1RL
FF
73
F0C
Timer 1 PWM High Byte
T1PWMH
00
73
F0D
Timer 1 PWM Low Byte
T1PWML
00
74
F0E
Timer 1 Control 0
T1CTL0
00
74
F0F
Timer 1 Control 1
T1CTL1
00
72
F10F3F
Reserved
--
XX
UART 0
F40
UART0 Transmit Data
U0TXD
XX
95
UART0 Receive Data
U0RXD
XX
96
XX=Undefined
PS024705-0405
P R E L I M I N A R Y Register
Map
Z8 Encore! XP
F08xA Series
Product Specification
16
F41
UART0 Status 0
U0STAT0
0000011Xb
96
F42
UART0 Control 0
U0CTL0
00
98
F43
UART0 Control 1
U0CTL1
00
99
F44
UART0 Status 1
U0STAT1
00
97
F45
UART0 Address Compare
U0ADDR
00
101
F46
UART0 Baud Rate High Byte
U0BRH
FF
101
F47
UART0 Baud Rate Low Byte
U0BRL
FF
101
F48F6F
Reserved
--
XX
Analog-to-Digital Converter (ADC)
F70
ADC Control 0
ADCCTL0
00
117
F71
ADC Control 1
ADCCTL1
80
117
F72
ADC Data High Byte
ADCD_H
XX
120
F73
ADC Data Low Bits
ADCD_L
XX
120
F74
ADC High Threshold High Byte
ADCTHH
FF
121
F75
Reserved
--
XX
F76
ADC Low Threshold High Byte
ADCTLH
00
121
F77F7F
Reserved
--
XX
Low Power Control
F80
Power Control 0
PWRCTL0
80
30
F81
Reserved
--
XX
LED Controller
F82
LED Drive Enable
LEDEN
00
44
F83
LED Drive Level High Byte
LEDLVLH
00
44
F84
LED Drive Level Low Byte
LEDLVLL
00
45
F85
Reserved
--
XX
Oscillator Control
F86
Oscillator Control
OSCCTL
A0
163
F87F8F
Reserved
--
XX
Comparator 0
F90
Comparator 0 Control
CMP0
14
123
F91FBF
Reserved
--
XX
Interrupt Controller
FC0
Interrupt Request 0
IRQ0
00
51
FC1
IRQ0 Enable High Bit
IRQ0ENH
00
53
Table 7. Register File Address Map (Continued)
Address (Hex)
Register Description
Mnemonic
Reset (Hex)
Page #
XX=Undefined
PS024705-0405
P R E L I M I N A R Y Register
Map
Z8 Encore! XP
F08xA Series
Product Specification
17
FC2
IRQ0 Enable Low Bit
IRQ0ENL
00
53
FC3
Interrupt Request 1
IRQ1
00
52
FC4
IRQ1 Enable High Bit
IRQ1ENH
00
54
FC5
IRQ1 Enable Low Bit
IRQ1ENL
00
55
FC6
Interrupt Request 2
IRQ2
00
52
FC7
IRQ2 Enable High Bit
IRQ2ENH
00
55
FC8
IRQ2 Enable Low Bit
IRQ2ENL
00
56
FC9FCC
Reserved
--
XX
FCD
Interrupt Edge Select
IRQES
00
57
FCE
Shared Interrupt Select
IRQSS
00
57
FCF
Interrupt Control
IRQCTL
00
57
GPIO Port A
FD0
Port A Address
PAADDR
00
37
FD1
Port A Control
PACTL
00
38
FD2
Port A Input Data
PAIN
XX
39
FD3
Port A Output Data
PAOUT
00
39
GPIO Port B
FD4
Port B Address
PBADDR
00
37
FD5
Port B Control
PBCTL
00
38
FD6
Port B Input Data
PBIN
XX
39
FD7
Port B Output Data
PBOUT
00
39
GPIO Port C
FD8
Port C Address
PCADDR
00
37
FD9
Port C Control
PCCTL
00
38
FDA
Port C Input Data
PCIN
XX
39
FDB
Port C Output Data
PCOUT
00
39
GPIO Port D
FDC
Port D Address
PDADDR
00
37
FDD
Port D Control
PDCTL
00
38
FDE
Reserved
--
XX
FDF
Port D Output Data
PDOUT
00
39
FE0FEF
Reserved
--
XX
Watch-Dog Timer (WDT)
Table 7. Register File Address Map (Continued)
Address (Hex)
Register Description
Mnemonic
Reset (Hex)
Page #
XX=Undefined
PS024705-0405
P R E L I M I N A R Y Register
Map
Z8 Encore! XP
F08xA Series
Product Specification
18
FF0
Reset Status
RSTSTAT
XX
82
Watch-Dog Timer Control
WDTCTL
XX
82
FF1
Watch-Dog Timer Reload Upper Byte
WDTU
FF
83
FF2
Watch-Dog Timer Reload High Byte
WDTH
FF
83
FF3
Watch-Dog Timer Reload Low Byte
WDTL
FF
83
FF4FF5
Reserved
--
XX
Trim Bit Control
FF6
Trim Bit Address
TRMADR
00
140
FF7
Trim Data
TRMDR
XX
140
Flash Memory Controller
FF8
Flash Control
FCTL
00
134
FF8
Flash Status
FSTAT
00
134
FF9
Flash Page Select
FPS
00
135
Flash Sector Protect
FPROT
00
136
FFA
Flash Programming Frequency High Byte FFREQH
00
137
FFB
Flash Programming Frequency Low Byte FFREQL
00
137
eZ8 CPU
FFC
Flags
--
XX
Refer to the
eZ8 CPU User
Manual
FFD
Register Pointer
RP
XX
FFE
Stack Pointer High Byte
SPH
XX
FFF
Stack Pointer Low Byte
SPL
XX
Table 7. Register File Address Map (Continued)
Address (Hex)
Register Description
Mnemonic
Reset (Hex)
Page #
XX=Undefined
PS024705-0405
P R E L I M I N A R Y
Reset and STOP Mode Recovery
Z8 Encore! XP
F08xA Series
Product Specification
19
Reset and STOP Mode Recovery
Overview
The Reset Controller within the Z8 Encore! XP
F08xA Series controls Reset and STOP
Mode Recovery operation and provides indication of low supply voltage conditions. In
typical operation, the following events cause a Reset:
Power-On Reset (POR)
Voltage Brown-Out (VBO)
Watch-Dog Timer time-out (when configured by the WDT_RES Flash Option Bit to
initiate a reset)
External RESET pin assertion (when the alternate RESET function is enabled by the
GPIO register)
On-Chip Debugger initiated Reset (OCDCTL[0] set to 1)
When the device is in STOP mode, a STOP Mode Recovery is initiated by either of the
following:
Watch-Dog Timer time-out
GPIO Port input pin transition on an enabled STOP Mode Recovery source
Reset Types
The Z8 Encore! XP
F08xA Series provides several different types of Reset operation.
STOP Mode Recovery is considered a form of Reset. Table 8 lists the types of Reset and
their operating characteristics. The System Reset is longer if the external crystal oscillator
is enabled by the Flash option bits, allowing additional time for oscillator start-up.
Table 8. Reset and STOP Mode Recovery Characteristics and Latency
Reset Type
Reset Characteristics and Latency
Control Registers
eZ8
CPU
Reset Latency (Delay)
System Reset
Reset (as applicable)
Reset 66 Internal Precision Oscillator Cycles
System Reset with Crystal
Oscillator Enabled
Reset (as applicable)
Reset 5000 Internal Precision Oscillator Cycles
PS024705-0405
P R E L I M I N A R Y
Reset and STOP Mode Recovery
Z8 Encore! XP
F08xA Series
Product Specification
20
During a System Reset or STOP Mode Recovery, the Internal Precision Oscillator requires
4
s to start up. Then, the Z8 Encore! XP
F08xA Series device is held in Reset for 66
cycles of the Internal Precision Oscillator. If the crystal oscillator is enabled in the Flash
option bits, this reset period is increased to 5000 IPO cycles. When a reset occurs because
of a low voltage condition or power on reset, this delay is measured from the time that the
supply voltage first exceeds the POR level (discussed later in this chapter). If the external
pin reset remains asserted at the end of the reset period, the device remains in reset until
the pin is deasserted.
At the beginning of Reset, all GPIO pins are configured as inputs with pull-up resistor dis-
abled, except PD0 which is shared with the reset pin. On reset, the Port D0 pin is config-
ured as a bidirectional open-drain reset. The pin is internally driven low during port reset,
after which the user code may reconfigure this pin as a general purpose output.
During Reset, the eZ8 CPU and on-chip peripherals are idle; however, the on-chip crystal
oscillator and Watch-Dog Timer oscillator continue to run.
Upon Reset, control registers within the Register File that have a defined Reset value are
loaded with their reset values. Other control registers (including the Stack Pointer, Regis-
ter Pointer, and Flags) and general-purpose RAM are undefined following Reset. The eZ8
CPU fetches the Reset vector at Program Memory addresses
0002H
and
0003H
and loads
that value into the Program Counter. Program execution begins at the Reset vector
address.
Because the control registers are re-initialized by a system reset, the system clock after
reset is always the IPO. User software must reconfigure the oscillator control block, such
that the correct system clock source is enabled and selected.
Reset Sources
Table 9 lists the possible sources of a system reset.
STOP Mode Recovery
Unaffected, except
WDT_CTL and
OSC_CTL registers
Reset 66 Internal Precision Oscillator Cycles
STOP Mode Recovery with
Crystal Oscillator Enabled
Unaffected, except
WDT_CTL and
OSC_CTL registers
Reset 5000 Internal Precision Oscillator Cycles
Table 8. Reset and STOP Mode Recovery Characteristics and Latency (Continued)
Reset Type
Reset Characteristics and Latency
Control Registers
eZ8
CPU
Reset Latency (Delay)
PS024705-0405
P R E L I M I N A R Y
Reset and STOP Mode Recovery
Z8 Encore! XP
F08xA Series
Product Specification
21
Power-On Reset
Each device in the Z8 Encore! XP
F08xA Series contains an internal Power-On Reset
(POR) circuit. The POR circuit monitors the supply voltage and holds the device in the
Reset state until the supply voltage reaches a safe operating level. After the supply voltage
exceeds the POR voltage threshold (V
POR
), the device is held in the Reset state until the
POR Counter has timed out. If the crystal oscillator is enabled by the option bits, this tim-
eout is longer.
After the ZZ8 Encore! XP
F08xA Series device exits the Power-On Reset state, the eZ8
CPU fetches the Reset vector. Following Power-On Reset, the POR status bit in the Watch-
Dog Timer Control (WDTCTL) register is set to 1.
Figure 4 illustrates Power-On Reset operation. Refer to the "Electrical Characteristics" on
page 191 for the POR threshold voltage (V
POR
).
Table 9. Reset Sources and Resulting Reset Type
Operating Mode
Reset Source
Special Conditions
NORMAL or HALT
modes
Power-On Reset / Voltage Brown-
Out
Reset delay begins after supply voltage
exceeds POR level
Watch-Dog Timer time-out
when configured for Reset
None
RESET pin assertion
All reset pulses less than three system clocks
in width are ignored.
On-Chip Debugger initiated Reset
(OCDCTL[0] set to 1)
System Reset, except the On-Chip Debugger
is unaffected by the reset
STOP mode
Power-On Reset / Voltage Brown-
Out
Reset delay begins after supply voltage
exceeds POR level
RESET pin assertion
All reset pulses less than the specified analog
delay are ignored. See "Electrical
Characteristics" on page 191.
DBG pin driven Low
None
PS024705-0405
P R E L I M I N A R Y
Reset and STOP Mode Recovery
Z8 Encore! XP
F08xA Series
Product Specification
22
Figure 4.Power-On Reset Operation
Voltage Brown-Out Reset
The devices in the Z8 Encore! XP
F08xA Series provide low Voltage Brown-Out (VBO)
protection. The VBO circuit senses when the supply voltage drops to an unsafe level
(below the VBO threshold voltage) and forces the device into the Reset state. While the
supply voltage remains below the Power-On Reset voltage threshold (V
POR
), the VBO
block holds the device in the Reset.
After the supply voltage again exceeds the Power-On Reset voltage threshold, the device
progresses through a full System Reset sequence, as described in the Power-On Reset sec-
tion. Following Power-On Reset, the POR status bit in the Reset Status (RSTSTAT) regis-
ter is set to 1. Figure 5 illustrates Voltage Brown-Out operation. Refer to the chapter
"Electrical Characteristics" on page 191 for the VBO and POR threshold voltages (V
VBO
and V
POR
).
The Voltage Brown-Out circuit can be either enabled or disabled during STOP mode.
Operation during STOP mode is set by the VBO_AO Flash Option Bit. Refer to the Flash
Option Bits chapter for information about configuring VBO_AO.
VCC = 0.0V
VCC = 3.3V
V
POR
V
VBO
Internal Precision
Internal RESET
signal
Program
Execution
Oscillator
Start-up
POR
counter delay
optional XTAL
counter delay
Oscillator
Crystal
Oscillator
Note: Not to Scale
PS024705-0405
P R E L I M I N A R Y
Reset and STOP Mode Recovery
Z8 Encore! XP
F08xA Series
Product Specification
23
Figure 5.Voltage Brown-Out Reset Operation
The POR level is greater than the VBO level by the specified hysteresis value. This
ensures that the device undergoes a power on reset after recovering from a VBO condition.
Watch-Dog Timer Reset
If the device is in NORMAL or STOP mode, the Watch-Dog Timer can initiate a System
Reset at time-out if the WDT_RES Flash Option Bit is programmed to 1. This is the
unprogrammed state of the WDT_RES Flash Option Bit. If the bit is programmed to 0, it
configures the Watch-Dog Timer to cause an interrupt, not a System Reset, at time-out.
The WDT status bit in the WDT Control register is set to signify that the reset was initi-
ated by the Watch-Dog Timer.
External Reset Input
The RESET pin has a Schmitt-triggered input and an internal pull-up resistor. Once the
RESET pin is asserted for a minimum of 4 system clock cycles, the device progresses
through the System Reset sequence. Because of the possible asynchronicity of the system
clock and reset signals, the required reset duration may be as short as three clock periods
VCC = 3.3V
V
POR
V
VBO
Internal RESET
signal
Program
Execution
Program
Execution
Voltage
Brownout
VCC = 3.3V
System Clock
WDT Clock
POR
counter delay
Note: Not to Scale
PS024705-0405
P R E L I M I N A R Y
Reset and STOP Mode Recovery
Z8 Encore! XP
F08xA Series
Product Specification
24
and as long as four. A reset pulse three clock cycles in duration might trigger a reset; a
pulse four cycles in duration always triggers a reset.
While the RESET input pin is asserted Low, the Z8 Encore! XP
F08xA Series devices
remain in the Reset state. If the RESET pin is held Low beyond the System Reset time-
out, the device exits the Reset state on the system clock rising edge following RESET pin
deassertion. Following a System Reset initiated by the external RESET pin, the EXT sta-
tus bit in the Watch-Dog Timer Control (WDTCTL) register is set to 1.
External Reset Indicator
During System Reset or when enabled by the GPIO logic (see
See "Port AD Control Reg-
isters" on page 38.
), the RESET pin functions as an open-drain (active low) reset mode
indicator in addition to the input functionality. This reset output feature allows an Z8
Encore! XP
F08xA Series device to reset other components to which it is connected,
even if that reset is caused by internal sources such as POR, VBO or WDT events.
After an internal reset event occurs, the internal circuitry begins driving the RESET pin
Low. The RESET pin is held Low by the internal circuitry until the appropriate delay
listed in Table 8 has elapsed.
On-Chip Debugger Initiated Reset
A Power-On Reset can be initiated using the On-Chip Debugger by setting the
RST
bit in
the OCD Control register. The On-Chip Debugger block is not reset but the rest of the chip
goes through a normal system reset. The
RST
bit automatically clears during the system
reset. Following the system reset the
POR
bit in the WDT Control register is set.
STOP Mode Recovery
STOP mode is entered by execution of a STOP instruction by the eZ8 CPU. Refer to the
chapter
"Low-Power Modes" on page 28
for detailed STOP mode information. During
STOP Mode Recovery, the CPU is held in reset for 66 IPO cycles if the crystal oscillator is
disabled or 5000 cycles if it is enabled.
STOP Mode Recovery does not affect onchip registers other than the Watchdog Timer
Control register (WDTCTL) and the Oscillator Control register (OSCCTL). After any
STOP Mode Recovery, the IPO is enabled and selected as the system clock. If another sys-
tem clock source is required or IPO disabling is required, the STOP Mode Recovery code
must reconfigure the oscillator control block such that the correct system clock source is
enabled and selected.
The eZ8 CPU fetches the Reset vector at Program Memory addresses
0002H
and
0003H
and loads that value into the Program Counter. Program execution begins at the Reset vec-
tor address. Following STOP Mode Recovery, the STOP bit in the Watch-Dog Timer Con-
PS024705-0405
P R E L I M I N A R Y
Reset and STOP Mode Recovery
Z8 Encore! XP
F08xA Series
Product Specification
25
trol Register is set to 1. Table 10 lists the STOP Mode Recovery sources and resulting
actions. The text following provides more detailed information about each of the STOP
Mode Recovery sources.
STOP Mode Recovery Using Watch-Dog Timer Time-Out
If the Watch-Dog Timer times out during STOP mode, the device undergoes a STOP
Mode Recovery sequence. In the Watch-Dog Timer Control register, the WDT and STOP
bits are set to 1. If the Watch-Dog Timer is configured to generate an interrupt upon time-
out and the Z8 Encore! XP
F08xA Series device is configured to respond to interrupts,
the eZ8 CPU services the Watch-Dog Timer interrupt request following the normal STOP
Mode Recovery sequence.
STOP Mode Recovery Using a GPIO Port Pin Transition
Each of the GPIO Port pins may be configured as a STOP Mode Recovery input source.
On any GPIO pin enabled as a STOP Mode Recovery source, a change in the input pin
value (from High to Low or from Low to High) initiates STOP Mode Recovery. In the
Watch-Dog Timer Control register, the STOP bit is set to 1.
In STOP mode, the GPIO Port Input Data registers (PxIN) are disabled. The Port Input
Data registers record the Port transition only if the signal stays on the Port pin through
the end of the STOP Mode Recovery delay. As a result, short pulses on the Port pin can
initiate STOP Mode Recovery without being written to the Port Input Data register or
without initiating an interrupt (if enabled for that pin).
Table 10. STOP Mode Recovery Sources and Resulting Action
Operating Mode
STOP Mode Recovery Source
Action
STOP mode
Watch-Dog Timer time-out
when configured for Reset
STOP Mode Recovery
Watch-Dog Timer time-out
when configured for interrupt
STOP Mode Recovery followed by
interrupt (if interrupts are enabled)
Data transition on any GPIO Port pin
enabled as a STOP Mode Recovery
source
STOP Mode Recovery
Assertion of external
RESET
Pin
System Reset
Debug Pin driven Low
System Reset
Caution:
PS024705-0405
P R E L I M I N A R Y
Reset and STOP Mode Recovery
Z8 Encore! XP
F08xA Series
Product Specification
26
STOP Mode Recovery Using the External RESET Pin
When the Z8 Encore! XP
F08xA Series device is in STOP Mode and the external
RESET pin is driven Low, a system reset occurs. Because of a glitch filter operating on the
RESET pin, the Low pulse must be greater than the minimum width specified, or it is
ignored. See
"Electrical Characteristics" on page 191
for details.
Reset Register Definitions
Reset Status Register
The Reset Status (RSTSTAT) register is a read-only register that indicates the source of
the most recent Reset event, indicates a STOP Mode Recovery event, and indicates a
Watch-Dog Timer time-out. Reading this register resets the upper four bits to 0.
This register shares its address with the Watch-Dog Timer control register, which is write-
only (Table 11).
POR--Power-On Reset Indicator
If this bit is set to 1, a Power-On Reset event occurred. This bit is reset to 0 if a WDT time-
out or STOP Mode Recovery occurs. This bit is also reset to 0 when the register is read.
STOP--STOP Mode Recovery Indicator
If this bit is set to 1, a STOP Mode Recovery occurred. If the STOP and WDT bits are both
Table 11. Reset Status Register (RSTSTAT)
BITS
7
6
5
4
3
2
1
0
FIELD
POR
STOP
WDT
EXT
Reserved
RESET
See descriptions below
0
0
0
0
0
R/W
R
R
R
R
R
R
R
R
ADDR
FF0H
Reset or STOP Mode Recovery Event
POR
STOP
WDT
EXT
Power-On Reset
1
0
0
0
Reset using RESET pin assertion
0
0
0
1
Reset using Watch-Dog Timer time-out
0
0
1
0
Reset using the On-Chip Debugger (OCTCTL[1] set to 1)
1
0
0
0
Reset from STOP Mode using DBG Pin driven Low
1
0
0
0
STOP Mode Recovery using GPIO pin transition
0
1
0
0
STOP Mode Recovery using Watch-Dog Timer time-out
0
1
1
0
PS024705-0405
P R E L I M I N A R Y
Reset and STOP Mode Recovery
Z8 Encore! XP
F08xA Series
Product Specification
27
set to 1, the STOP Mode Recovery occurred because of a WDT time-out. If the STOP bit
is 1 and the WDT bit is 0, the STOP Mode Recovery was not caused by a WDT time-out.
This bit is reset by a Power-On Reset or a WDT time-out that occurred while not in STOP
mode. Reading this register also resets this bit.
WDT--Watch-Dog Timer Time-Out Indicator
If this bit is set to 1, a WDT time-out occurred. A Power-On Reset resets this pin. A STOP
Mode Recovery from a change in an input pin also resets this bit. Reading this register
resets this bit. This read must occur before clearing the WDT interrupt.
EXT--External Reset Indicator
If this bit is set to 1, a Reset initiated by the external RESET pin occurred. A Power-On
Reset or a STOP Mode Recovery from a change in an input pin resets this bit. Reading this
register resets this bit.
Reserved--Must be 0.
PS024705-0405
P R E L I M I N A R Y Low-Power
Modes
Z8 Encore! XP
F08xA Series
Product Specification
28
Low-Power Modes
Overview
The Z8 Encore! XP
F08xA Series products contain power-saving features. The highest
level of power reduction is provided by the STOP mode. The next lower level of power
reduction is provided by the HALT mode.
Further power savings can be implemented by disabling individual peripheral blocks
while in Normal mode.
STOP Mode
Executing the eZ8 CPU's STOP instruction places the device into STOP mode. In STOP
mode, the operating characteristics are:
Primary crystal oscillator and internal precision oscillator are stopped; XIN and XOUT (if
previously enabled) are disabled, and PA0/PA1 revert to the states programmed by the
GPIO registers
System clock is stopped
eZ8 CPU is stopped
Program counter (PC) stops incrementing
Watch-Dog Timer's internal RC oscillator continues to operate if enabled by the Oscillator
Control Register
If enabled, the Watch-Dog Timer logic continues to operate
If enabled for operation in STOP mode by the associated Flash Option Bit, the Voltage-
brown out protection circuit continues to operate
Transimpedance amplifier in the ADC block continues to operate if enabled by the Power
Control Register to do so; all other portions of the ADC are disabled
All other on-chip peripherals are idle
To minimize current in STOP mode, all GPIO pins that are configured as digital inputs
must be driven to one of the supply rails (V
CC
or GND). The device can be brought out of
STOP mode using STOP Mode Recovery. For more information about STOP Mode
Recovery refer to
"Reset and STOP Mode Recovery" on page 19
.
PS024705-0405
P R E L I M I N A R Y Low-Power
Modes
Z8 Encore! XP
F08xA Series
Product Specification
29
HALT Mode
Executing the eZ8 CPU's HALT instruction places the device into HALT mode. In HALT
mode, the operating characteristics are:
Primary oscillator is enabled and continues to operate
System clock is enabled and continues to operate
eZ8 CPU is stopped
Program counter (PC) stops incrementing
Watch-Dog Timer's internal RC oscillator continues to operate
If enabled, the Watch-Dog Timer continues to operate
All other on-chip peripherals continue to operate
The eZ8 CPU can be brought out of HALT mode by any of the following operations:
Interrupt
Watch-Dog Timer time-out (interrupt or reset)
Power-on reset
Voltage-brown out reset
External RESET pin assertion
To minimize current in HALT mode, all GPIO pins that are configured as inputs must be
driven to one of the supply rails (V
CC
or GND).
Peripheral-Level Power Control
In addition to the STOP and Halt modes, it is possible to disable each peripheral on each
of the Z8 Encore! XP
F08xA Series devices. Disabling a given peripheral minimizes its
power consumption.
Power Control Register Definitions
Power Control Register 0
Each bit of the following registers disables a peripheral block, either by gating its system
clock input or by removing power from the block.
The default state of the transimpedance amplifier is OFF. To use the transimpedance
amplifier, clear the TRAM bit, turning it ON. Clearing this bit might interfere with normal
PS024705-0405
P R E L I M I N A R Y Low-Power
Modes
Z8 Encore! XP
F08xA Series
Product Specification
30
ADC measurements on ANA0 (the transimpedance output). This bit enables the amplifier
even in STOP mode. If the amplifier is not required in STOP mode, disable it. Failure to
perform this results in STOP mode currents greater than specified.
This register is only reset during a power-on reset sequence. Other system reset events do
not affect it.
TRAM-- Transimpedance Amplifier Disable
0 = Transimpedance Amplifier is enabled (this applies even in STOP mode).
1 = Transimpedance Amplifier is disabled.
Reserved--Must be 0.
VBO--Voltage Brown-Out Detector Disable
This bit and the VBO_AO Flash option bit must both enable the VBO for the VBO to be
active.
0 = VBO Enabled
1 = VBO Disabled
TEMP--Temperature Sensor Disable
0 = Temperature Sensor Enabled
1 = Temperature Sensor Disabled
ADC--Analog-to-Digital Converter Disable
0 = Analog-to-Digital Converter Enabled
1 = Analog-to-Digital Converter Disabled
COMP--Comparator Disable
0 = Comparator is Enabled
1 = Comparator is Disabled
Reserved--Must be 0.
Table 12. Power Control Register 0 (PWRCTL0)
BITS
7
6
5
4
3
2
1
0
FIELD
TRAM
Reserved
VBO
TEMP
ADC
COMP
Reserved
RESET
1
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F80H
Note:
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
31
General-Purpose I/O
Overview
The Z8 Encore! XP
F08xA Series products support a maximum of 25 port pins (Ports A
D) for general-purpose input/output (GPIO) operations. Each port contains control and
data registers. The GPIO control registers determine data direction, open-drain, output
drive current, programmable pull-ups, STOP Mode Recovery functionality, and alternate
pin functions. Each port pin is individually programmable. In addition, the Port C pins are
capable of direct LED drive at programmable drive strengths.
GPIO Port Availability By Device
Table 13 lists the port pins available with each device and package type.
Architecture
Figure 6 illustrates a simplified block diagram of a GPIO port pin. In this figure, the abil-
ity to accommodate alternate functions and variable port current drive strength is not illus-
trated.
Table 13. Port Availability by Device and Package Type
Devices
Package 10-Bit ADC
Port A
Port B
Port C
Port D Total I/O
Z8F082APH, Z8F082AHH
20-pin
Yes
[7:0]
[3:0]
[3:0]
[0]
17
Z8F081APH, Z8F081AHH
20-pin
No
[7:0]
[3:0]
[3:0]
[0]
17
Z8F082APJ, Z8F082ASJ
28-pin
Yes
[7:0]
[5:0]
[7:0]
[0]
23
Z8F081APJ, Z8F081ASJ
28-pin
No
[7:0]
[7:0]
[7:0]
[0]
25
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
32
Figure 6.GPIO Port Pin Block Diagram
GPIO Alternate Functions
Many of the GPIO port pins can be used for general-purpose I/O and access to on-chip
peripheral functions such as the timers and serial communication devices. The Port AD
Alternate Function sub-registers configure these pins for either General-Purpose I/O or
alternate function operation. When a pin is configured for alternate function, control of the
port pin direction (input/output) is passed from the Port AD Data Direction registers to
the alternate function assigned to this pin. Table 14 on page 34 lists the alternate functions
possible with each port pin. The alternate function associated at a pin is defined through
Alternate Function Sets sub-registers AFS1 and AFS2.
The crystal oscillator functionality is not controlled by the GPIO block. When the crystal
oscillator is enabled in the oscillator control block, the GPIO functionality of PA0 and PA1
is overridden. In that case, those pins function as input and output for the crystal oscillator.
PA0 and PA6 contain two different timer functions, a timer input and a complementary
timer output. Both of these functions require the same GPIO configuration, the selection
between the two is based on the timer mode. See
"Timers" on page 58
for more details.
D
Q
D
Q
D
Q
GND
VDD
Port Output Control
Port Data Direction
Port Output
Data Register
Port Input
Data Register
Port
Pin
DATA
Bus
System
Clock
System
Clock
Schmitt Trigger
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
33
Direct LED Drive
The Port C pins provide a current sinked output capable of driving an LED without requir-
ing an external resistor. The output sinks current at programmable levels of 3mA, 7mA,
13mA and 20mA. This mode is enabled through the Alternate Function sub-register AFS1
and is programmable through the LED control registers.
For correct function, the LED anode must be connected to V
DD
and the cathode to the
GPIO pin.
Using all Port C pins in LED drive mode with maximum current may result in excessive
total current. Refer to the
"Electrical Characteristics" on page 191
for the maximum total
current for the applicable package.
Shared Reset Pin
On the 20 and 28-pin devices, the Port D0 pin shares function with a bi-directional reset
pin. Unlike all other I/O pins, this pin does not default to GPIO function on power-up.
This pin acts as a bi-directional reset until user software re-configures it. The Port D0 pin
is output-only when in GPIO mode.
Crystal Oscillator Override
For systems using a crystal oscillator, PA0 and PA1 are used to connect the crystal. When
the crystal oscillator is enabled (see
"Oscillator Control Register Definitions" on page 163
),
the GPIO settings are overridden and PA0 and PA1 are disabled.
5V Tolerance
In the 20- and 28-pin versions of this device, any pin which shares functionality with an
ADC, crystal or comparator port is not 5V-tolerant, including PA[1:0], PB[5:0] and
PC[2:0]. All other signal pins are 5V-tolerant, and can safely handle inputs higher than
V
DD
even with the pull-ups enabled.
External Clock Setup
For systems using an external TTL drive, PB3 is the clock source for 20- and 28-pin
devices. In this case, configure PB3 for alternate function CLKIN. Write the Oscillator
Control Register (page 163) such that the external oscillator is selected as the system clock
For 8-pin devices use PA1 instead of PB3.
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
34
Table 14. Port Alternate Function Mapping (20/28-Pin Parts)
Port
Pin
Mnemonic
Alternate Function Description
Alternate
Function Set
Register AFS1
Port A
PA0
T0IN/T0OUT
Timer 0 Input/Timer 0 Output Complement N/A
Reserved
PA1
T0OUT
Timer 0 Output
Reserved
PA2
DE0
UART 0 Driver Enable
Reserved
PA3
CTS0
UART 0 Clear to Send
Reserved
PA4
RXD0/IRRX0
UART 0 / IrDA 0 Receive Data
Reserved
PA5
TXD0/IRTX0
UART 0 / IrDA 0 Transmit Data
Reserved
PA6
T1IN/T1OUT
Timer 1 Input/Timer 1 Output Complement
Reserved
PA7
T1OUT
Timer 1 Output
Reserved
Note: Because there is only a single alternate function for each Port A pin, the Alternate Function
Set registers are not implemented for Port A. Enabling alternate function selections as described in
"Port AD Alternate Function Sub-Registers" on page 39 automatically enables the associated
alternate function.
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
35
Port B
PB0
Reserved
AFS1[0]: 0
ANA0/AMPOUT
ADC Analog Input/Transamp Output
AFS1[0]: 1
PB1
Reserved
AFS1[1]: 0
ANA1/AMPINN
ADC Analog Input/Transamp Input (N)
AFS1[1]: 1
PB2
Reserved
AFS1[2]: 0
ANA2/AMPINP
ADC Analog Input/Transamp Input (P)
AFS1[2]: 1
PB3
CLKIN
External Clock Input
AFS1[3]: 0
ANA3
ADC Analog Input
AFS1[3]: 1
PB4
Reserved
AFS1[4]: 0
ANA7
ADC Analog Input
AFS1[4]: 1
PB5
Reserved
AFS1[5]: 0
VREF
ADC Voltage Reference
AFS1[5]: 1
PB6
Reserved
AFS1[6]: 0
Reserved
AFS1[6]: 1
PB7
Reserved
AFS1[7]: 0
Reserved
AFS1[7]: 1
Note: Because there are at most two choices of alternate function for any pin of Port B, the Alternate
Function Set register AFS2 is implemented but not used to select the function. Also, alternate
function selection as described in "Port AD Alternate Function Sub-Registers" on page 39 must
also be enabled.
Table 14. Port Alternate Function Mapping (Continued)(20/28-Pin Parts)
Port
Pin
Mnemonic
Alternate Function Description
Alternate
Function Set
Register AFS1
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
36
GPIO Interrupts
Many of the GPIO port pins can be used as interrupt sources. Some port pins can be con-
figured to generate an interrupt request on either the rising edge or falling edge of the pin
input signal. Other port pin interrupt sources generate an interrupt when any edge occurs
(both rising and falling). Refer to the chapter
"Interrupt Controller" on page 46
for more
information about interrupts using the GPIO pins.
Port C
PC0
Reserved
AFS1[0]: 0
ANA4/CINP/LED
Drive
ADC or Comparator Input, or LED drive
AFS1[0]: 1
PC1
Reserved
AFS1[1]: 0
ANA5/CINN/ LED
Drive
ADC or Comparator Input, or LED drive
AFS1[1]: 1
PC2
Reserved
AFS1[2]: 0
ANA6/LED
ADC Analog Input or LED Drive
AFS1[2]: 1
PC3
COUT
Comparator Output
AFS1[3]: 0
LED
LED drive
AFS1[3]: 1
PC4
Reserved
AFS1[4]: 0
LED
LED Drive
AFS1[4]: 1
PC5
Reserved
AFS1[5]: 0
LED
LED Drive
AFS1[5]: 1
PC6
Reserved
AFS1[6]: 0
LED
LED Drive
AFS1[6]: 1
PC7
Reserved
AFS1[7]: 0
LED
LED Drive
AFS1[7]: 1
Note: Because there are at most two choices of alternate function for any pin of Port C, the Alternate
Function Set register AFS2 is implemented but not used to select the function. Also, alternate
function selection as described in "Port AD Alternate Function Sub-Registers" on page 39 must
also be enabled.
Table 14. Port Alternate Function Mapping (Continued)(20/28-Pin Parts)
Port
Pin
Mnemonic
Alternate Function Description
Alternate
Function Set
Register AFS1
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
37
GPIO Control Register Definitions
Four registers for each Port provide access to GPIO control, input data, and output data.
Table 15 lists these Port registers. Use the Port AD Address and Control registers
together to provide access to sub-registers for Port configuration and control.
Port AD Address Registers
The Port AD Address registers select the GPIO Port functionality accessible through the
Port AD Control registers. The Port AD Address and Control registers combine to pro-
vide access to all GPIO Port controls (Table 16).
Table 15. GPIO Port Registers and Sub-Registers
Port Register Mnemonic
Port Register Name
PxADDR
Port AD Address Register
(Selects sub-registers)
PxCTL
Port AD Control Register
(Provides access to sub-registers)
PxIN
Port AD Input Data Register
PxOUT
Port AD Output Data Register
Port Sub-Register Mnemonic
Port Register Name
PxDD
Data Direction
PxAF
Alternate Function
PxOC
Output Control (Open-Drain)
PxHDE
High Drive Enable
PxSMRE
STOP Mode Recovery Source Enable
PxPUE
Pull-up Enable
PxAFS1
Alternate Function Set 1
PxAFS2
Alternate Function Set 2
Table 16. Port AD GPIO Address Registers (PxADDR)
BITS
7
6
5
4
3
2
1
0
FIELD
PADDR[7:0]
RESET
00H
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FD0H, FD4H, FD8H, FDCH
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
38
PADDR[7:0]--Port Address
The Port Address selects one of the sub-registers accessible through the Port Control reg-
ister.
Port AD Control Registers
The Port AD Control registers set the GPIO port operation. The value in the correspond-
ing Port AD Address register determines which sub-register is read from or written to by
a Port AD Control register transaction (Table 17).
PCTL[7:0]--Port Control
The Port Control register provides access to all sub-registers that configure the GPIO Port
operation.
Port AD Data Direction Sub-Registers
The Port AD Data Direction sub-register is accessed through the Port AD Control regis-
ter by writing 01H to the Port AD Address register (Table 18).
PADDR[7:0] Port Control sub-register accessible using the Port AD Control Registers
00H
No function. Provides some protection against accidental Port reconfiguration.
01H
Data Direction
02H
Alternate Function
03H
Output Control (Open-Drain)
04H
High Drive Enable
05H
STOP Mode Recovery Source Enable.
06H
Pull-up Enable
07H
Alternate Function Set 1
08H
Alternate Function Set 2
09HFFH
No function
Table 17. Port AD Control Registers (PxCTL)
BITS
7
6
5
4
3
2
1
0
FIELD
PCTL
RESET
00H
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FD1H, FD5H, FD9H, FDDH
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
39
DD[7:0]--Data Direction
These bits control the direction of the associated port pin. Port Alternate Function opera-
tion overrides the Data Direction register setting.
0 = Output. Data in the Port AD Output Data register is driven onto the port pin.
1 = Input. The port pin is sampled and the value written into the Port AD Input Data Reg-
ister. The output driver is tristated.
Port AD Alternate Function Sub-Registers
The Port AD Alternate Function sub-register (Table 19) is accessed through the Port A
D Control register by writing
02H
to the Port AD Address register. The Port AD Alter-
nate Function sub-registers enable the alternate function selection on pins. If disabled, pins
functions as GPIO. If enabled, select one of four alternate functions using alternate func-
tion set subregisters 1 and 2 as described in the
"Port AD Alternate Function Set 1 Sub-
Registers" on page 42
and
"Port AD Alternate Function Set 2 Sub-Registers" on page 42.
Refer
to the
"GPIO Alternate Functions" on page 32
to determine the alternate function asso-
ciated with each port pin.
Do not enable alternate functions for GPIO port pins for which there is no
associated alternate function. Failure to follow this guideline can result in
unpredictable operation.
AF[7:0]--Port Alternate Function enabled
0 = The port pin is in normal mode and the DDx bit in the Port AD Data Direction sub-
register determines the direction of the pin.
Table 18. Port AD Data Direction Sub-Registers (PxDD)
BITS
7
6
5
4
3
2
1
0
FIELD
DD7
DD6
DD5
DD4
DD3
DD2
DD1
DD0
RESET
1
1
1
1
1
1
1
1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
If 01H in Port AD Address Register, accessible through the Port AD Control Register
Table 19. Port AD Alternate Function Sub-Registers (PxAF)
BITS
7
6
5
4
3
2
1
0
FIELD
AF7
AF6
AF5
AF4
AF3
AF2
AF1
AF0
RESET
00H (Ports AC); 01H (Port D)
R/W
R/W
ADDR
If 02H in Port AD Address Register, accessible through the Port AD Control Register
Caution:
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
40
1 = The alternate function selected through Alternate Function Set sub-registers is
enabled. Port pin operation is controlled by the alternate function.
Port AD Output Control Sub-Registers
The Port AD Output Control sub-register (Table 20) is accessed through the Port AD
Control register by writing
03H
to the Port AD Address register. Setting the bits in the
Port AD Output Control sub-registers to 1 configures the specified port pins for open-
drain operation. These sub-registers affect the pins directly and, as a result, alternate func-
tions are also affected.
POC[7:0]--Port Output Control
These bits function independently of the alternate function bit and always disable the
drains if set to 1.
0 = The drains are enabled for any output mode (unless overridden by the alternate func-
tion).
1 = The drain of the associated pin is disabled (open-drain mode).
Port AD High Drive Enable Sub-Registers
The Port AD High Drive Enable sub-register (Table 21) is accessed through the Port
AD Control register by writing
04H
to the Port AD Address register. Setting the bits in
the Port AD High Drive Enable sub-registers to 1 configures the specified port pins for
high current output drive operation. The Port AD High Drive Enable sub-register affects
the pins directly and, as a result, alternate functions are also affected.
Table 20. Port AD Output Control Sub-Registers (PxOC)
BITS
7
6
5
4
3
2
1
0
FIELD
POC7
POC6
POC5
POC4
POC3
POC2
POC1
POC0
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
If 03H in Port AD Address Register, accessible through the Port AD Control Register
Table 21. Port AD High Drive Enable Sub-Registers (PxHDE)
BITS
7
6
5
4
3
2
1
0
FIELD
PHDE7
PHDE6
PHDE5
PHDE4
PHDE3
PHDE2
PHDE1
PHDE0
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
If 04H in Port AD Address Register, accessible through the Port AD Control Register
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
41
PHDE[7:0]--Port High Drive Enabled
0 = The Port pin is configured for standard output current drive.
1 = The Port pin is configured for high output current drive.
Port AD STOP Mode Recovery Source Enable Sub-Registers
The Port AD STOP Mode Recovery Source Enable sub-register (Table 22) is accessed
through the Port AD Control register by writing
05H
to the Port AD Address register.
Setting the bits in the Port AD STOP Mode Recovery Source Enable sub-registers to 1
configures the specified Port pins as a STOP Mode Recovery source. During STOP Mode,
any logic transition on a Port pin enabled as a STOP Mode Recovery source initiates
STOP Mode Recovery.
PSMRE[7:0]--Port STOP Mode Recovery Source Enabled
0 = The Port pin is not configured as a STOP Mode Recovery source. Transitions on this
pin during STOP mode do not initiate STOP Mode Recovery.
1 = The Port pin is configured as a STOP Mode Recovery source. Any logic transition on
this pin during STOP mode initiates STOP Mode Recovery.
Port AD Pull-up Enable Sub-Registers
The Port AD Pull-up Enable sub-register (Table 23) is accessed through the Port AD
Control register by writing
06H
to the Port AD Address register. Setting the bits in the
Port AD Pull-up Enable sub-registers enables a weak internal resistive pull-up on the
specified Port pins.
Table 22. Port AD STOP Mode Recovery Source Enable Sub-Registers (PxSMRE)
BITS
7
6
5
4
3
2
1
0
FIELD
PSMRE7
PSMRE6
PSMRE5
PSMRE4
PSMRE3
PSMRE2
PSMRE1
PSMRE0
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
If 05H in Port AD Address Register, accessible through the Port AD Control Register
Table 23. Port AD Pull-Up Enable Sub-Registers (PxPUE)
BITS
7
6
5
4
3
2
1
0
FIELD
PPUE7
PPUE6
PPUE5
PPUE4
PPUE3
PPUE2
PPUE1
PPUE0
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
If 06H in Port A
D Address Register, accessible through the Port A
D Control Register
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
42
PPUE[7:0]--Port Pull-up Enabled
0 = The weak pull-up on the Port pin is disabled.
1 = The weak pull-up on the Port pin is enabled.
Port AD Alternate Function Set 1 Sub-Registers
The Port AD Alternate Function Set1 sub-register (Table 24) is accessed through the Port
AD Control register by writing
07H
to the Port AD Address register. The Alternate
Function Set 1 sub-registers selects the alternate function available at a port pin. Alternate
Functions selected by setting or clearing bits of this register are defined in
"GPIO Alternate
Functions" on page 32
.
Alternate function selection on port pins must also be enabled as decribed in
"Port AD
Alternate Function Sub-Registers" on page 39.
PAFS1[7:0]--Port Alternate Function Set 1
0 = Port Alternate Function selected as defined in Table 13 in the
GPIO Alternate Functions
section.
1 = Port Alternate Function selected as defined in Table 13 in the
GPIO Alternate Functions
section.
Port AD Alternate Function Set 2 Sub-Registers
The Port AD Alternate Function Set 2 sub-register (Table 25) is accessed through the
Port AD Control register by writing
08H
to the Port AD Address register. The Alternate
Function Set 2 sub-registers selects the alternate function available at a port pin. Alternate
Functions selected by setting or clearing bits of this register is defined in Table 13 in the
section
"GPIO Alternate Functions" on page 32
.
Alternate function selection on port pins must also be enabled as decribed in
"Port AD
Alternate Function Sub-Registers" on page 39.
Table 24. Port AD Alternate Function Set 1 Sub-Registers (PxAFS1)
BITS
7
6
5
4
3
2
1
0
FIELD
PAFS17
PAFS16
PAFS15
PAFS14
PAFS13
PAFS12
PAFS11
PAFS10
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
If 07H in Port AD Address Register, accessible through the Port AD Control Register
Table 25. Port AD Alternate Function Set 2 Sub-Registers (PxAFS2)
BITS
7
6
5
4
3
2
1
0
FIELD
PAFS27
PAFS26
PAFS25
PAFS24
PAFS23
PAFS22
PAFS21
PAFS20
Note:
Note:
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
43
PAFS2[7:0]--Port Alternate Function Set 2
0 = Port Alternate Function selected as defined in Table 13
GPIO Alternate Functions
sec-
tion.
1 = Port Alternate Function selected as defined in Table 13
GPIO Alternate Functions
sec-
tion.
Port AC Input Data Registers
Reading from the Port AC Input Data registers (Table 26) returns the sampled values
from the corresponding port pins. The Port AC Input Data registers are read-only. The
value returned for any unused ports is 0. Unused ports include those missing on the 8- and
28-pin packages, as well as those missing on the ADC-enabled 28-pin packages.
PIN[7:0]--Port Input Data
Sampled data from the corresponding port pin input.
0 = Input data is logical 0 (Low).
1 = Input data is logical 1 (High).
Port AD Output Data Register
The Port AD Output Data register (Table 27) controls the output data to the pins.
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
If 08H in Port AD Address Register, accessible through the Port AD Control Register
Table 26. Port AC Input Data Registers (PxIN)
BITS
7
6
5
4
3
2
1
0
FIELD
PIN7
PIN6
PIN5
PIN4
PIN3
PIN2
PIN1
PIN0
RESET
X
X
X
X
X
X
X
X
R/W
R
R
R
R
R
R
R
R
ADDR
FD2H, FD6H, FDAH
Table 27. Port AD Output Data Register (PxOUT)
BITS
7
6
5
4
3
2
1
0
FIELD
POUT7
POUT6
POUT5
POUT4
POUT3
POUT2
POUT1
POUT0
RESET
0
0
0
0
0
0
0
0
Table 25. Port AD Alternate Function Set 2 Sub-Registers (PxAFS2)
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
44
POUT[7:0]--Port Output Data
These bits contain the data to be driven to the port pins. The values are only driven if the
corresponding pin is configured as an output and the pin is not configured for alternate
function operation.
0 = Drive a logical 0 (Low).
1= Drive a logical 1 (High). High value is not driven if the drain has been disabled by set-
ting the corresponding Port Output Control register bit to 1.
LED Drive Enable Register
The LED Drive Enable register (Table 28) activates the controlled current drive. The Port
C pin must first be enabled by setting the Alternate Function register to select the LED
function.
.
LEDEN[7:0]--LED Drive Enable
These bits determine which Port C pins are connected to an internal current sink.
0 = Tristate the Port C pin.
1= Connect controlled current sink to the Port C pin.
LED Drive Level High Register
The LED Drive Level registers contain two control bits for each Port C pin (Table 29).
These two bits select between four programmable drive levels. Each pin is individually
programmable.
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FD3H, FD7H, FDBH, FDFH
Table 28. LED Drive Enable (LEDEN)
BITS
7
6
5
4
3
2
1
0
FIELD
LEDEN[7:0]
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F82H
Table 29. LED Drive Level High Register (LEDLVLH)
BITS
7
6
5
4
3
2
1
0
FIELD
LEDLVLH[7:0]
RESET
0
0
0
0
0
0
0
0
Table 27. Port AD Output Data Register (PxOUT)
PS024705-0405
P R E L I M I N A R Y General-Purpose
I/O
Z8 Encore! XP
F08xA Series
Product Specification
45
LEDLVLH[7:0]--LED Level High Bit
{LEDLVLH, LEDLVLL} select one of four programmable current drive levels for each
Port C pin.
00 = 3 mA
01= 7 mA
10= 13 mA
11= 20 mA
LED Drive Level Low Register
The LED Drive Level registers contain two control bits for each Port C pin (Table 30).
These two bits select between four programmable drive levels. Each pin is individually
programmable.
LEDLVLH[7:0]--LED Level High Bit
{LEDLVLH, LEDLVLL} select one of four programmable current drive levels for each
Port C pin.
00 = 3 mA
01 = 7 mA
10 = 13 mA
11 = 20 mA
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F83H
Table 30. LED Drive Level Low Register (LEDLVLL)
BITS
7
6
5
4
3
2
1
0
FIELD
LEDLVLL[7:0]
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F84H
Table 29. LED Drive Level High Register (LEDLVLH)
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
46
Interrupt Controller
Overview
The interrupt controller on the XP 8K Series products prioritizes the interrupt requests
from the on-chip peripherals and the GPIO port pins. The features of the interrupt control-
ler include the following:
20 unique interrupt vectors:
14 GPIO port pin interrupt sources (two are shared)
10 on-chip peripheral interrupt sources (two are shared)
Flexible GPIO interrupts
8 selectable rising and falling edge GPIO interrupts
4 dual-edge interrupts
3 levels of individually programmable interrupt priority
Watch-Dog Timer and Low Voltage Detect (LVD) can be configured to generate an inter-
rupt
Interrupt requests (IRQs) allow peripheral devices to suspend CPU operation in an orderly
manner and force the CPU to start an interrupt service routine (ISR). Usually this interrupt
service routine is involved with the exchange of data, status information, or control infor-
mation between the CPU and the interrupting peripheral. When the service routine is com-
pleted, the CPU returns to the operation from which it was interrupted.
The eZ8 CPU supports both vectored and polled interrupt handling. For polled interrupts,
the interrupt controller has no effect on operation. Refer to the eZ8 CPU User Manual for
more information regarding interrupt servicing by the eZ8 CPU. The eZ8 CPU User Man-
ual
is available for download at
www.zilog.com
.
Interrupt Vector Listing
Table 31 lists all of the interrupts available in order of priority. The interrupt vector is
stored with the most significant byte (MSB) at the even Program Memory address and the
least significant byte (LSB) at the following odd Program Memory address.
Some port interrupts are not available on the 8- and 20-pin packages. The ADC interrupt is
unavailable on devices not containing an ADC.
Note:
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
47
Table 31. Trap and Interrupt Vectors in Order of Priority
Priority
Program Memory
Vector Address
Interrupt or Trap Source
Highest 0002H
Reset (not an interrupt)
0004H
Watch-Dog Timer (see Watch-Dog Timer chapter)
003AH
Primary Oscillator Fail Trap (not an interrupt)
003CH
Watchdog Oscillator Fail Trap (not an interrupt)
0006H
Illegal Instruction Trap (not an interrupt)
0008H
Reserved
000AH
Timer 1
000CH
Timer 0
000EH
UART 0 receiver
0010H
UART 0 transmitter
0012H
Reserved
0014H
Reserved
0016H
ADC
0018H
Port A7, selectable rising or falling input edge
001AH
Port A6, selectable rising or falling input edge or Comparator Output
001CH
Port A5, selectable rising or falling input edge
001EH
Port A4, selectable rising or falling input edge
0020H
Port A3 or Port D3, selectable rising or falling input edge
0022H
Port A2 or Port D2, selectable rising or falling input edge
0024H
Port A1, selectable rising or falling input edge
0026H
Port A0, selectable rising or falling input edge
0028H
Reserved
002AH
Reserved
002CH
Reserved
002EH
Reserved
0030H
Port C3, both input edges
0032H
Port C2, both input edges
0034H
Port C1, both input edges
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
48
Architecture
Figure 7 illustrates the interrupt controller block diagram.
Figure 7.Interrupt Controller Block Diagram
Operation
Master Interrupt Enable
The master interrupt enable bit (IRQE) in the Interrupt Control register globally enables
and disables interrupts.
Interrupts are globally enabled by any of the following actions:
Execution of an EI (Enable Interrupt) instruction
Execution of an IRET (Return from Interrupt) instruction
Lowest
0036H
Port C0, both input edges
0038H
Reserved
Table 31. Trap and Interrupt Vectors in Order of Priority (Continued)
Priority
Program Memory
Vector Address
Interrupt or Trap Source
Vector
IRQ Request
High
Priority
Medium
Priority
Low
Priority
Priority
Mux
Interrupt
Requ
est La
tch
e
s a
nd
Con
t
rol
Port Interrupts
Internal Interrupts
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
49
Writing a 1 to the IRQE bit in the Interrupt Control register
Interrupts are globally disabled by any of the following actions:
Execution of a DI (Disable Interrupt) instruction
eZ8 CPU acknowledgement of an interrupt service request from the interrupt controller
Writing a 0 to the IRQE bit in the Interrupt Control register
Reset
Execution of a Trap instruction
Illegal Instruction Trap
Primary Oscillator Fail Trap
Watch-Dog Oscillator Fail Trap
Interrupt Vectors and Priority
The interrupt controller supports three levels of interrupt priority. Level 3 is the highest
priority, Level 2 is the second highest priority, and Level 1 is the lowest priority. If all of
the interrupts are enabled with identical interrupt priority (all as Level 2 interrupts, for
example), the interrupt priority is assigned from highest to lowest as specified in Table 31
on page 47. Level 3 interrupts are always assigned higher priority than Level 2 interrupts
which, in turn, always are assigned higher priority than Level 1 interrupts. Within each
interrupt priority level (Level 1, Level 2, or Level 3), priority is assigned as specified in
Table 31, above. Reset, Watch-Dog Timer interrupt (if enabled), Primary Oscillator Fail
Trap, Watchdog Oscillator Fail Trap, and Illegal Instruction Trap always have highest
(level 3) priority.
Interrupt Assertion
Interrupt sources assert their interrupt requests for only a single system clock period (sin-
gle pulse). When the interrupt request is acknowledged by the eZ8 CPU, the correspond-
ing bit in the Interrupt Request register is cleared until the next interrupt occurs. Writing a
0 to the corresponding bit in the Interrupt Request register likewise clears the interrupt
request.
The following coding style that clears bits in the Interrupt Request registers is NOT rec-
ommended. All incoming interrupts received between execution of the first LDX com-
mand and the final LDX command are lost.
Poor coding style that can result in lost interrupt requests:
LDX r0, IRQ0
AND r0, MASK
LDX IRQ0, r0
Caution:
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
50
To avoid missing interrupts, use the following coding style to clear bits in
the Interrupt Request 0 register:
Good coding style that avoids lost interrupt requests:
ANDX IRQ0, MASK
Software Interrupt Assertion
Program code can generate interrupts directly. Writing a 1 to the correct bit in the Interrupt
Request register triggers an interrupt (assuming that interrupt is enabled). When the inter-
rupt request is acknowledged by the eZ8 CPU, the bit in the Interrupt Request register is
automatically cleared to 0.
The following coding style used to generate software interrupts by setting bits in the In-
terrupt Request registers is NOT recommended. All incoming interrupts received be-
tween execution of the first LDX command and the final LDX command are lost.
Poor coding style that can result in lost interrupt requests:
LDX r0, IRQ0
OR r0, MASK
LDX IRQ0, r0
To avoid missing interrupts, use the following coding style to set bits in the Interrupt Re-
quest registers:
Good coding style that avoids lost interrupt requests:
ORX IRQ0, MASK
Interrupt Control Register Definitions
For all interrupts other than the Watch-Dog Timer interrupt, the Primary Oscillator Fail
Trap, and the Watchdog Oscillator Fail Trap, the interrupt control registers enable individ-
ual interrupts, set interrupt priorities, and indicate interrupt requests.
Interrupt Request 0 Register
The Interrupt Request 0 (IRQ0) register (Table 32) stores the interrupt requests for both
vectored and polled interrupts. When a request is presented to the interrupt controller, the
corresponding bit in the IRQ0 register becomes 1. If interrupts are globally enabled (vec-
tored interrupts), the interrupt controller passes an interrupt request to the eZ8 CPU. If
interrupts are globally disabled (polled interrupts), the eZ8 CPU can read the Interrupt
Request 0 register to determine if any interrupt requests are pending.
Caution:
Caution:
Caution:
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
51
Reserved--Must be 0.
T1I--Timer 1 Interrupt Request
0 = No interrupt request is pending for Timer 1.
1 = An interrupt request from Timer 1 is awaiting service.
T0I--Timer 0 Interrupt Request
0 = No interrupt request is pending for Timer 0.
1 = An interrupt request from Timer 0 is awaiting service.
U0RXI--UART 0 Receiver Interrupt Request
0 = No interrupt request is pending for the UART 0 receiver.
1 = An interrupt request from the UART 0 receiver is awaiting service.
U0TXI--UART 0 Transmitter Interrupt Request
0 = No interrupt request is pending for the UART 0 transmitter.
1 = An interrupt request from the UART 0 transmitter is awaiting service.
ADCI--ADC Interrupt Request
0 = No interrupt request is pending for the Analog-to-Digital Converter.
1 = An interrupt request from the Analog-to-Digital Converter is awaiting service.
Interrupt Request 1 Register
The Interrupt Request 1 (IRQ1) register (Table 33) stores interrupt requests for both vec-
tored and polled interrupts. When a request is presented to the interrupt controller, the cor-
responding bit in the IRQ1 register becomes 1. If interrupts are globally enabled (vectored
interrupts), the interrupt controller passes an interrupt request to the eZ8 CPU. If interrupts
are globally disabled (polled interrupts), the eZ8 CPU can read the Interrupt Request 1
register to determine if any interrupt requests are pending.
Table 32. Interrupt Request 0 Register (IRQ0)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
T1I
T0I
U0RXI
U0TXI
Reserved Reserved
ADCI
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FC0H
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
52
PA7VI--Port A7 or LVD Interrupt Request
0 = No interrupt request is pending for GPIO Port A or LVD.
1 = An interrupt request from GPIO Port A or LVD.
PA6CI--Port A6 or Comparator Interrupt Request
0 = No interrupt request is pending for GPIO Port A or Comparator.
1 = An interrupt request from GPIO Port A or Comparator.
PAxI--Port A Pin x Interrupt Request
0 = No interrupt request is pending for GPIO Port A pin x.
1 = An interrupt request from GPIO Port A pin x is awaiting service.
where x indicates the specific GPIO Port pin number (05).
Interrupt Request 2 Register
The Interrupt Request 2 (IRQ2) register (Table 34) stores interrupt requests for both vec-
tored and polled interrupts. When a request is presented to the interrupt controller, the cor-
responding bit in the IRQ2 register becomes 1. If interrupts are globally enabled (vectored
interrupts), the interrupt controller passes an interrupt request to the eZ8 CPU. If interrupts
are globally disabled (polled interrupts), the eZ8 CPU can read the Interrupt Request 2
register to determine if any interrupt requests are pending.
Reserved--Must be 0.
PCxI--Port C Pin x Interrupt Request
0 = No interrupt request is pending for GPIO Port C pin x.
1 = An interrupt request from GPIO Port C pin x is awaiting service.
where x indicates the specific GPIO Port C pin number (03).
Table 33. Interrupt Request 1 Register (IRQ1)
BITS
7
6
5
4
3
2
1
0
FIELD
PA7VI
PA6CI
PA5I
PA4I
PA3I
PA2I
PA1I
PA0I
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FC3H
Table 34. Interrupt Request 2 Register (IRQ2)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
PC3I
PC2I
PC1I
PC0I
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FC6H
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
53
IRQ0 Enable High and Low Bit Registers
Table 35 describes the priority control for IRQ0. The IRQ0 Enable High and Low Bit reg-
isters (Tables 36 and 37) form a priority encoded enabling for interrupts in the Interrupt
Request 0 register. Priority is generated by setting bits in each register.
Reserved--Must be 0.
T1ENH--Timer 1 Interrupt Request Enable High Bit
T0ENH--Timer 0 Interrupt Request Enable High Bit
U0RENH--UART 0 Receive Interrupt Request Enable High Bit
U0TENH--UART 0 Transmit Interrupt Request Enable High Bit
ADCENH--ADC Interrupt Request Enable High Bit
Reserved--Must be 0.
Table 35. IRQ0 Enable and Priority Encoding
IRQ0ENH[x] IRQ0ENL[x] Priority
Description
0
0
Disabled
Disabled
0
1
Level 1
Low
1
0
Level 2
Nominal
1
1
Level 3
High
where x indicates the register bits from 07.
Table 36. IRQ0 Enable High Bit Register (IRQ0ENH)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
T1ENH
T0ENH
U0RENH
U0TENH
Reserved Reserved ADCENH
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FC1H
Table 37. IRQ0 Enable Low Bit Register (IRQ0ENL)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
T1ENL
T0ENL
U0RENL
U0TENL
Reserved Reserved
ADCENL
RESET
0
0
0
0
0
0
0
0
R/W
R
R/W
R/W
R/W
R/W
R
R
R/W
ADDR
FC2H
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
54
T1ENL--Timer 1 Interrupt Request Enable Low Bit
T0ENL--Timer 0 Interrupt Request Enable Low Bit
U0RENL--UART 0 Receive Interrupt Request Enable Low Bit
U0TENL--UART 0 Transmit Interrupt Request Enable Low Bit
ADCENL--ADC Interrupt Request Enable Low Bit
IRQ1 Enable High and Low Bit Registers
Table 38 describes the priority control for IRQ1. The IRQ1 Enable High and Low Bit reg-
isters (Tables 39 and 40) form a priority encoded enabling for interrupts in the Interrupt
Request 1 register. Priority is generated by setting bits in each register.
PA6CENH--Port A Bit[6] or Comparator Interrupt Request Enable High Bit
PAxENH--Port A Bit[x] Interrupt Request Enable High Bit
Refer to the Shared Interrupt Select register for selection of either Port A or Port D as the
interrupt source.
Table 38. IRQ1 Enable and Priority Encoding
IRQ1ENH[x] IRQ1ENL[x] Priority
Description
0
0
Disabled
Disabled
0
1
Level 1
Low
1
0
Level 2
Nominal
1
1
Level 3
High
where x indicates the register bits from 07.
Table 39. IRQ1 Enable High Bit Register (IRQ1ENH)
BITS
7
6
5
4
3
2
1
0
FIELD
PA7ENH PA6CENH PA5ENH
PA4ENH
PA3ENH
PA2ENH
PA1ENH
PA0ENH
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FC4H
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
55
PA6CENH--Port A Bit[6] or Comparator Interrupt Request Enable Low Bit
PAxENL--Port A Bit[x] Interrupt Request Enable Low Bit
IRQ2 Enable High and Low Bit Registers
Table 41 describes the priority control for IRQ2. The IRQ2 Enable High and Low Bit reg-
isters (Tables 42 and 43) form a priority encoded enabling for interrupts in the Interrupt
Request 2 register. Priority is generated by setting bits in each register.
Reserved--Must be 0.
C3ENH--Port C3 Interrupt Request Enable High Bit
C2ENH--Port C2 Interrupt Request Enable High Bit
Table 40. IRQ1 Enable Low Bit Register (IRQ1ENL)
BITS
7
6
5
4
3
2
1
0
FIELD
PA7ENL
PA6CENL
PA5ENL
PA4ENL
PA3ENL
PA2ENL
PA1ENL
PA0ENL
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FC5H
Table 41. IRQ2 Enable and Priority Encoding
IRQ2ENH[x] IRQ2ENL[x] Priority
Description
0
0
Disabled
Disabled
0
1
Level 1
Low
1
0
Level 2
Nominal
1
1
Level 3
High
where x indicates the register bits from 07.
Table 42. IRQ2 Enable High Bit Register (IRQ2ENH)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
C3ENH
C2ENH
C1ENH
C0ENH
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FC7H
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
56
C1ENH--Port C1 Interrupt Request Enable High Bit
C0ENH--Port C0 Interrupt Request Enable High Bit
Reserved--Must be 0.
C3ENL--Port C3 Interrupt Request Enable Low Bit
C2ENL--Port C2 Interrupt Request Enable Low Bit
C1ENL--Port C1 Interrupt Request Enable Low Bit
C0ENL--Port C0 Interrupt Request Enable Low Bit
Interrupt Edge Select Register
The Interrupt Edge Select (IRQES) register (Table 44) determines whether an interrupt is
generated for the rising edge or falling edge on the selected GPIO Port A or Port D input
pin.
IESx--Interrupt Edge Select x
0 = An interrupt request is generated on the falling edge of the PAx input or PDx.
1 = An interrupt request is generated on the rising edge of the PAx input PDx.
where x indicates the specific GPIO Port pin number (0 through 7).
Shared Interrupt Select Register
The Shared Interrupt Select (IRQSS) register (Table 45) determines the source of the
PADxS interrupts. The Shared Interrupt Select register (Table 45) selects between Port A
and alternate sources for the individual interrupts.
Table 43. IRQ2 Enable Low Bit Register (IRQ2ENL)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
C3ENL
C2ENL
C1ENL
C0ENL
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FC8H
Table 44. Interrupt Edge Select Register (IRQES)
BITS
7
6
5
4
3
2
1
0
FIELD
IES7
IES6
IES5
IES4
IES3
IES2
IES1
IES0
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FCDH
PS024705-0405
P R E L I M I N A R Y Interrupt
Controller
Z8 Encore! XP
F08xA Series
Product Specification
57
Because these shared interrupts are edge-triggered, it is possible to generate an interrupt
just by switching from one shared source to another. For this reason, an interrupt must be
disabled before switching between sources.
PA6CS--PA6/Comparator Selection
0 = PA6 is used for the interrupt for PA6CS interrupt request.
1 = The Comparator is used for the interrupt for PA6CS interrupt request.
Reserved--Must be 0.
Interrupt Control Register
The Interrupt Control (IRQCTL) register (Table 46) contains the master enable bit for all
interrupts.
IRQE--Interrupt Request Enable
This bit is set to 1 by executing an EI (Enable Interrupts) or IRET (Interrupt Return)
instruction, or by a direct register write of a 1 to this bit. It is reset to 0 by executing a DI
instruction, eZ8 CPU acknowledgement of an interrupt request, Reset or by a direct regis-
ter write of a 0 to this bit.
0 = Interrupts are disabled.
1 = Interrupts are enabled.
Reserved--Must be 0.
Table 45. Shared Interrupt Select Register (IRQSS)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
PA6CS
Reserved
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FCEH
Table 46. Interrupt Control Register (IRQCTL)
BITS
7
6
5
4
3
2
1
0
FIELD
IRQE
Reserved
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R
R
R
R
R
R
R
ADDR
FCFH
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
58
Timers
Overview
These Z8 Encore! XP
F08xA Series products contain up to two 16-bit reloadable timers
that can be used for timing, event counting, or generation of pulse-width modulated
(PWM) signals. The timers' features include:
16-bit reload counter
Programmable prescaler with prescale values from 1 to 128
PWM output generation
Capture and compare capability
External input pin for timer input, clock gating, or capture signal. External input pin signal
frequency is limited to a maximum of one-fourth the system clock frequency.
Timer output pin
Timer interrupt
In addition to the timers described in this chapter, the Baud Rate Generator of the UART
(if unused) may also provide basic timing functionality. Refer to chapter
"UART" on
page 84
for information about using the Baud Rate Generator as an additional timer.
Architecture
Figure 8 illustrates the architecture of the timers.
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
59
Figure 8.Timer Block Diagram
Operation
The timers are 16-bit up-counters. Minimum time-out delay is set by loading the value
0001H
into the Timer Reload High and Low Byte registers and setting the prescale value
to 1. Maximum time-out delay is set by loading the value
0000H
into the Timer Reload
High and Low Byte registers and setting the prescale value to 128. If the Timer reaches
FFFF
H
, the timer rolls over to
0000
H
and continues counting.
Timer Operating Modes
The timers can be configured to operate in the following modes:
ONE-SHOT Mode
In ONE-SHOT mode, the timer counts up to the 16-bit Reload value stored in the Timer
Reload High and Low Byte registers. The timer input is the system clock. Upon reaching
the Reload value, the timer generates an interrupt and the count value in the Timer High
and Low Byte registers is reset to
0001
H
. The timer is automatically disabled and stops
counting.
Also, if the Timer Output alternate function is enabled, the Timer Output pin changes state
for one system clock cycle (from Low to High or from High to Low) upon timer Reload. If
16-Bit
PWM/Compare
16-Bit Counter
with Prescaler
16-Bit
Reload Register
Timer
Control
Co
mp
are
Co
mp
are
Interrupt,
PWM,
and
Timer Output
Control
Timer
Timer Block
System
Timer
Data
Block
Output
Control
Bus
Clock
Input
Gate
Input
Capture
Input
Timer
Interrupt
Timer
Output
Complement
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
60
it is appropriate to have the Timer Output make a state change at a One-Shot time-out
(rather than a single cycle pulse), first set the TPOL bit in the Timer Control Register to
the start value before enabling ONE-SHOT mode. After starting the timer, set TPOL to the
opposite bit value.
The steps for configuring a timer for ONE-SHOT mode and initiating the count are as fol-
lows:
1. Write to the Timer Control register to:
Disable the timer
Configure the timer for ONE-SHOT mode.
Set the prescale value.
Set the initial output level (High or Low) if using the Timer Output alternate
function.
2. Write to the Timer High and Low Byte registers to set the starting count value.
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. If appropriate, enable the timer interrupt and set the timer interrupt priority by writing
to the relevant interrupt registers.
5. If using the Timer Output function, configure the associated GPIO port pin for the
Timer Output alternate function.
6. Write to the Timer Control register to enable the timer and initiate counting.
In ONE-SHOT mode, the system clock always provides the timer input. The timer period
is given by the following equation:
CONTINUOUS Mode
In CONTINUOUS mode, the timer counts up to the 16-bit Reload value stored in the
Timer Reload High and Low Byte registers. The timer input is the system clock. Upon
reaching the Reload value, the timer generates an interrupt, the count value in the Timer
High and Low Byte registers is reset to
0001H
and counting resumes. Also, if the Timer
Output alternate function is enabled, the Timer Output pin changes state (from Low to
High or from High to Low) at timer Reload.
The steps for configuring a timer for CONTINUOUS mode and initiating the count are as
follows:
1. Write to the Timer Control register to:
Disable the timer
Configure the timer for CONTINUOUS mode.
Set the prescale value.
One-Shot Mode Time-Out Period (s)
Reload Value Start Value
(
)
Prescale
System Clock Frequency (Hz)
-------------------------------------------------------------------------------------------------
=
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
61
If using the Timer Output alternate function, set the initial output level (High or
Low).
2. Write to the Timer High and Low Byte registers to set the starting count value (usually
0001H
). This action only affects the first pass in CONTINUOUS mode. After the first
timer Reload in CONTINUOUS mode, counting always begins at the reset value of
0001H
.
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. Enable the timer interrupt (if appropriate) and set the timer interrupt priority by
writing to the relevant interrupt registers.
5. Configure the associated GPIO port pin (if using the Timer Output function) for the
Timer Output alternate function.
6. Write to the Timer Control register to enable the timer and initiate counting.
In CONTINUOUS mode, the system clock always provides the timer input. The timer
period is given by the following equation:
If an initial starting value other than
0001H
is loaded into the Timer High and Low Byte
registers, use the ONE-SHOT mode equation to determine the first time-out period.
COUNTER Mode
In COUNTER mode, the timer counts input transitions from a GPIO port pin. The timer
input is taken from the GPIO Port pin Timer Input alternate function. The TPOL bit in the
Timer Control Register selects whether the count occurs on the rising edge or the falling
edge of the Timer Input signal. In COUNTER mode, the prescaler is disabled.
The input frequency of the Timer Input signal must not exceed one-fourth the system
clock frequency.
Upon reaching the Reload value stored in the Timer Reload High and Low Byte registers,
the timer generates an interrupt, the count value in the Timer High and Low Byte registers
is reset to
0001H
and counting resumes. Also, if the Timer Output alternate function is
enabled, the Timer Output pin changes state (from Low to High or from High to Low) at
timer Reload.
The steps for configuring a timer for COUNTER mode and initiating the count are as fol-
lows:
1. Write to the Timer Control register to:
Disable the timer
Configure the timer for COUNTER mode
Continuous Mode Time-Out Period (s)
Reload Value Prescale
System Clock Frequency (Hz)
----------------------------------------------------------------------------
=
Caution:
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
62
Select either the rising edge or falling edge of the Timer Input signal for the count.
This selection also sets the initial logic level (High or Low) for the Timer Output
alternate function. However, the Timer Output function is not required to be
enabled.
2. Write to the Timer High and Low Byte registers to set the starting count value. This
only affects the first pass in COUNTER mode. After the first timer Reload in
COUNTER mode, counting always begins at the reset value of
0001H
. In COUNTER
mode the Timer High and Low Byte registers must be written with the value
0001H
.
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. If appropriate, enable the timer interrupt and set the timer interrupt priority by writing
to the relevant interrupt registers.
5. Configure the associated GPIO port pin for the Timer Input alternate function.
6. If using the Timer Output function, configure the associated GPIO port pin for the
Timer Output alternate function.
7. Write to the Timer Control register to enable the timer.
In COUNTER mode, the number of Timer Input transitions since the timer start is given
by the following equation:
COMPARATOR COUNTER Mode
In COMPARATOR COUNTER mode, the timer counts input transitions from the analog
comparator output. The TPOL bit in the Timer Control Register selects whether the count
occurs on the rising edge or the falling edge of the comparator output signal. In COMPAR-
ATOR COUNTER mode, the prescaler is disabled.
The frequency of the comparator output signal must not exceed one-fourth the system
clock frequency.
After reaching the Reload value stored in the Timer Reload High and Low Byte registers,
the timer generates an interrupt, the count value in the Timer High and Low Byte registers
is reset to
0001H
and counting resumes. Also, if the Timer Output alternate function is
enabled, the Timer Output pin changes state (from Low to High or from High to Low) at
timer Reload.
The steps for configuring a timer for COMPARATOR COUNTER mode and initiating the
count are as follows:
1. Write to the Timer Control register to:
Disable the timer
Configure the timer for COMPARATOR COUNTER mode
Counter Mode Timer Input Transitions
Current Count Value Start Value
=
Caution:
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
63
Select either the rising edge or falling edge of the comparator output signal for the
count. This also sets the initial logic level (High or Low) for the Timer Output
alternate function. However, the Timer Output function is not required to be
enabled.
2. Write to the Timer High and Low Byte registers to set the starting count value. This
action only affects the first pass in COMPARATOR COUNTER mode. After the first
timer Reload in COMPARATOR COUNTER mode, counting always begins at the
reset value of
0001H
. Generally, in COMPARATOR COUNTER mode the Timer
High and Low Byte registers must be written with the value
0001H
.
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. If appropriate, enable the timer interrupt and set the timer interrupt priority by writing
to the relevant interrupt registers.
5. If using the Timer Output function, configure the associated GPIO port pin for the
Timer Output alternate function.
6. Write to the Timer Control register to enable the timer.
In COMPARATOR COUNTER mode, the number of comparator output transitions since
the timer start is given by the following equation:
PWM SINGLE OUTPUT Mode
In PWM SINGLE OUTPUT mode, the timer outputs a Pulse-Width Modulator (PWM)
output signal through a GPIO Port pin. The timer input is the system clock. The timer first
counts up to the 16-bit PWM match value stored in the Timer PWM High and Low Byte
registers. When the timer count value matches the PWM value, the Timer Output toggles.
The timer continues counting until it reaches the Reload value stored in the Timer Reload
High and Low Byte registers. Upon reaching the Reload value, the timer generates an
interrupt, the count value in the Timer High and Low Byte registers is reset to
0001H
and
counting resumes.
If the TPOL bit in the Timer Control register is set to 1, the Timer Output signal begins as
a High (1) and transitions to a Low (0) when the timer value matches the PWM value. The
Timer Output signal returns to a High (1) after the timer reaches the Reload value and is
reset to
0001H
.
If the TPOL bit in the Timer Control register is set to 0, the Timer Output signal begins as
a Low (0) and transitions to a High (1) when the timer value matches the PWM value. The
Timer Output signal returns to a Low (0) after the timer reaches the Reload value and is
reset to
0001H
.
The steps for configuring a timer for PWM Single Output mode and initiating the PWM
operation are as follows:
Comparator Output Transitions
Current Count Value Start Value
=
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
64
1. Write to the Timer Control register to:
Disable the timer
Configure the timer for PWM mode.
Set the prescale value.
Set the initial logic level (High or Low) and PWM High/Low transition for the
Timer Output alternate function.
2. Write to the Timer High and Low Byte registers to set the starting count value
(typically
0001H
). This only affects the first pass in PWM mode. After the first timer
reset in PWM mode, counting always begins at the reset value of
0001H
.
3. Write to the PWM High and Low Byte registers to set the PWM value.
4. Write to the Timer Reload High and Low Byte registers to set the Reload value (PWM
period). The Reload value must be greater than the PWM value.
5. If appropriate, enable the timer interrupt and set the timer interrupt priority by writing
to the relevant interrupt registers.
6. Configure the associated GPIO port pin for the Timer Output alternate function.
7. Write to the Timer Control register to enable the timer and initiate counting.
The PWM period is represented by the following equation:
If an initial starting value other than
0001H
is loaded into the Timer High and Low Byte
registers, use the ONE-SHOT mode equation to determine the first PWM time-out period.
If TPOL is set to 0, the ratio of the PWM output High time to the total period is repre-
sented by:
If TPOL is set to 1, the ratio of the PWM output High time to the total period is repre-
sented by:
PWM Dual Output Mode
In PWM DUAL OUTPUT mode, the timer outputs a Pulse-Width Modulated (PWM) out-
put signal pair (basic PWM signal and its complement) through two GPIO Port pins. The
timer input is the system clock. The timer first counts up to the 16-bit PWM match value
PWM Period (s)
Reload Value
Prescale
System Clock Frequency (Hz)
----------------------------------------------------------------------------
=
PWM Output High Time Ratio (%)
Reload Value PWM Value
Reload Value
------------------------------------------------------------------------
100
=
PWM Output High Time Ratio (%)
PWM Value
Reload Value
----------------------------------
100
=
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
65
stored in the Timer PWM High and Low Byte registers. When the timer count value
matches the PWM value, the Timer Output toggles. The timer continues counting until it
reaches the Reload value stored in the Timer Reload High and Low Byte registers. Upon
reaching the Reload value, the timer generates an interrupt, the count value in the Timer
High and Low Byte registers is reset to
0001H
and counting resumes.
If the TPOL bit in the Timer Control register is set to 1, the Timer Output signal begins as
a High (1) and transitions to a Low (0) when the timer value matches the PWM value. The
Timer Output signal returns to a High (1) after the timer reaches the Reload value and is
reset to
0001H
.
If the TPOL bit in the Timer Control register is set to 0, the Timer Output signal begins as
a Low (0) and transitions to a High (1) when the timer value matches the PWM value. The
Timer Output signal returns to a Low (0) after the timer reaches the Reload value and is
reset to
0001H
.
The timer also generates a second PWM output signal Timer Output Complement. The
Timer Output Complement is the complement of the Timer Output PWM signal. A pro-
grammable deadband delay can be configured to time delay (0 to 128 system clock cycles)
PWM output transitions on these two pins from a low to a high (inactive to active). This
ensures a time gap between the deassertion of one PWM output to the assertion of its com-
plement.
The steps for configuring a timer for PWM Dual Output mode and initiating the PWM
operation are as follows:
1. Write to the Timer Control register to:
Disable the timer
Configure the timer for PWM Dual Output mode. Setting the mode also involves
writing to TMODEHI bit in TxCTL1 register.
Set the prescale value.
Set the initial logic level (High or Low) and PWM High/Low transition for the
Timer Output alternate function.
2. Write to the Timer High and Low Byte registers to set the starting count value
(typically
0001H
). This only affects the first pass in PWM mode. After the first timer
reset in PWM mode, counting always begins at the reset value of
0001H
.
3. Write to the PWM High and Low Byte registers to set the PWM value.
4. Write to the PWM Control register to set the PWM dead band delay value. The
deadband delay must be less than the duration of the positive phase of the PWM signal
(as defined by the PWM high and low byte registers). It must also be less than the
duration of the negative phase of the PWM signal (as defined by the difference
between the PWM registers and the Timer Reload registers).
5. Write to the Timer Reload High and Low Byte registers to set the Reload value (PWM
period). The Reload value must be greater than the PWM value.
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
66
6. If appropriate, enable the timer interrupt and set the timer interrupt priority by writing
to the relevant interrupt registers.
7. Configure the associated GPIO port pin for the Timer Output and Timer Output
Complement alternate functions. The Timer Output Complement function is shared
with the Timer Input function for both timers. Setting the timer mode to Dual PWM
automatically switches the function from Timer In to Timer Out Complement.
8. Write to the Timer Control register to enable the timer and initiate counting.
The PWM period is represented by the following equation:
If an initial starting value other than
0001H
is loaded into the Timer High and Low Byte
registers, the ONE-SHOT mode equation determines the first PWM time-out period.
If TPOL is set to 0, the ratio of the PWM output High time to the total period is repre-
sented by:
If TPOL is set to 1, the ratio of the PWM output High time to the total period is repre-
sented by:
CAPTURE Mode
In CAPTURE mode, the current timer count value is recorded when the appropriate exter-
nal Timer Input transition occurs. The Capture count value is written to the Timer PWM
High and Low Byte Registers. The timer input is the system clock. The TPOL bit in the
Timer Control register determines if the Capture occurs on a rising edge or a falling edge
of the Timer Input signal. When the Capture event occurs, an interrupt is generated and the
timer continues counting. The INPCAP bit in TxCTL1 register is set to indicate the timer
interrupt is because of an input capture event.
The timer continues counting up to the 16-bit Reload value stored in the Timer Reload
High and Low Byte registers. Upon reaching the Reload value, the timer generates an
interrupt and continues counting. The INPCAP bit in TxCTL1 register clears indicating
the timer interrupt is not because of an input capture event.
The steps for configuring a timer for CAPTURE mode and initiating the count are as fol-
lows:
PWM Period (s)
Reload Value
Prescale
System Clock Frequency (Hz)
----------------------------------------------------------------------------
=
PWM Output High Time Ratio (%)
Reload Value PWM Value
Reload Value
------------------------------------------------------------------------
100
=
PWM Output High Time Ratio (%)
PWM Value
Reload Value
----------------------------------
100
=
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
67
1. Write to the Timer Control register to:
Disable the timer
Configure the timer for CAPTURE mode.
Set the prescale value.
Set the Capture edge (rising or falling) for the Timer Input.
2. Write to the Timer High and Low Byte registers to set the starting count value
(typically
0001H
).
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. Clear the Timer PWM High and Low Byte registers to 0000H. Clearing these
registers allows user software to determine if interrupts were generated by either a
capture event or a reload. If the PWM High and Low Byte registers still contain
0000H
after the interrupt, the interrupt was generated by a Reload.
5. Enable the timer interrupt, if appropriate, and set the timer interrupt priority by writing
to the relevant interrupt registers. By default, the timer interrupt is generated for both
input capture and reload events. If appropriate, configure the timer interrupt to be
generated only at the input capture event or the reload event by setting TICONFIG
field of the TxCTL1 register.
6. Configure the associated GPIO port pin for the Timer Input alternate function.
7. Write to the Timer Control register to enable the timer and initiate counting.
In CAPTURE mode, the elapsed time from timer start to Capture event can be calculated
using the following equation:
CAPTURE RESTART Mode
In CAPTURE RESTART mode, the current timer count value is recorded when the accept-
able external Timer Input transition occurs. The Capture count value is written to the
Timer PWM High and Low Byte Registers. The timer input is the system clock. The
TPOL
bit in the Timer Control register determines if the Capture occurs on a rising edge or
a falling edge of the Timer Input signal. When the Capture event occurs, an interrupt is
generated and the count value in the Timer High and Low Byte registers is reset to
0001H
and counting resumes. The INPCAP bit in TxCTL1 register is set to indicate the timer
interrupt is because of an input capture event.
If no Capture event occurs, the timer counts up to the 16-bit Compare value stored in the
Timer Reload High and Low Byte registers. Upon reaching the Reload value, the timer
generates an interrupt, the count value in the Timer High and Low Byte registers is reset to
0001H
and counting resumes. The INPCAP bit in TxCTL1 register is cleared to indicate
the timer interrupt is not caused by an input capture event.
Capture Elapsed Time (s)
Capture Value Start Value
(
)
Prescale
System Clock Frequency (Hz)
----------------------------------------------------------------------------------------------------
=
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
68
The steps for configuring a timer for CAPTURE RESTART mode and initiating the count
are as follows:
1. Write to the Timer Control register to:
Disable the timer
Configure the timer for CAPTURE RESTART mode. Setting the mode also
involves writing to
TMODEHI
bit in TxCTL1 register.
Set the prescale value.
Set the Capture edge (rising or falling) for the Timer Input.
2. Write to the Timer High and Low Byte registers to set the starting count value
(typically
0001H
).
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. Clear the Timer PWM High and Low Byte registers to 0000H. This allows user
software to determine if interrupts were generated by either a capture event or a
reload. If the PWM High and Low Byte registers still contain 0000H after the
interrupt, the interrupt was generated by a Reload.
5. Enable the timer interrupt, if appropriate, and set the timer interrupt priority by writing
to the relevant interrupt registers. By default, the timer interrupt is generated for both
input capture and reload events. If appropriate, configure the timer interrupt to be
generated only at the input capture event or the reload event by setting TICONFIG
field of the TxCTL1 register.
6. Configure the associated GPIO port pin for the Timer Input alternate function.
7. Write to the Timer Control register to enable the timer and initiate counting.
In CAPTURE mode, the elapsed time from timer start to Capture event can be calculated
using the following equation:
COMPARE Mode
In COMPARE mode, the timer counts up to the 16-bit maximum Compare value stored in
the Timer Reload High and Low Byte registers. The timer input is the system clock. Upon
reaching the Compare value, the timer generates an interrupt and counting continues (the
timer value is not reset to
0001H
). Also, if the Timer Output alternate function is enabled,
the Timer Output pin changes state (from Low to High or from High to Low) upon Com-
pare.
If the Timer reaches
FFFF
H
, the timer rolls over to
0000
H
and continue counting.
The steps for configuring a timer for COMPARE mode and initiating the count are as fol-
lows:
Capture Elapsed Time (s)
Capture Value Start Value
(
)
Prescale
System Clock Frequency (Hz)
----------------------------------------------------------------------------------------------------
=
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
69
1. Write to the Timer Control register to:
Disable the timer
Configure the timer for Compare mode.
Set the prescale value.
Set the initial logic level (High or Low) for the Timer Output alternate function, if
appropriate.
2. Write to the Timer High and Low Byte registers to set the starting count value.
3. Write to the Timer Reload High and Low Byte registers to set the Compare value.
4. Enable the timer interrupt, if appropriate, and set the timer interrupt priority by writing
to the relevant interrupt registers.
5. If using the Timer Output function, configure the associated GPIO port pin for the
Timer Output alternate function.
6. Write to the Timer Control register to enable the timer and initiate counting.
In Compare mode, the system clock always provides the timer input. The Compare time
can be calculated by the following equation:
GATED Mode
In GATED mode, the timer counts only when the Timer Input signal is in its active state
(asserted), as determined by the TPOL bit in the Timer Control register. When the Timer
Input signal is asserted, counting begins. A timer interrupt is generated when the Timer
Input signal is deasserted or a timer reload occurs. To determine if a Timer Input signal
deassertion generated the interrupt, read the associated GPIO input value and compare to
the value stored in the TPOL bit.
The timer counts up to the 16-bit Reload value stored in the Timer Reload High and Low
Byte registers. The timer input is the system clock. When reaching the Reload value, the
timer generates an interrupt, the count value in the Timer High and Low Byte registers is
reset to
0001H
and counting resumes (assuming the Timer Input signal remains asserted).
Also, if the Timer Output alternate function is enabled, the Timer Output pin changes state
(from Low to High or from High to Low) at timer reset.
The steps for configuring a timer for GATED mode and initiating the count are as follows:
1. Write to the Timer Control register to:
Disable the timer
Configure the timer for Gated mode.
Set the prescale value.
Compare Mode Time (s)
Compare Value Start Value
(
)
Prescale
System Clock Frequency (Hz)
-------------------------------------------------------------------------------------------------------
=
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
70
2. Write to the Timer High and Low Byte registers to set the starting count value. Writing
these registers only affects the first pass in GATED mode. After the first timer reset in
GATED mode, counting always begins at the reset value of
0001H
.
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. Enable the timer interrupt, if appropriate, and set the timer interrupt priority by writing
to the relevant interrupt registers. By default, the timer interrupt is generated for both
input deassertion and reload events. If appropriate, configure the timer interrupt to be
generated only at the input deassertion event or the reload event by setting TICONFIG
field of the TxCTL1 register.
5. Configure the associated GPIO port pin for the Timer Input alternate function.
6. Write to the Timer Control register to enable the timer.
7. Assert the Timer Input signal to initiate the counting.
CAPTURE/COMPARE Mode
In CAPTURE/COMPARE mode, the timer begins counting on the first external Timer
Input transition. The acceptable transition (rising edge or falling edge) is set by the TPOL
bit in the Timer Control Register. The timer input is the system clock.
Every subsequent acceptable transition (after the first) of the Timer Input signal captures
the current count value. The Capture value is written to the Timer PWM High and Low
Byte Registers. When the Capture event occurs, an interrupt is generated, the count value
in the Timer High and Low Byte registers is reset to
0001H
, and counting resumes. The
INPCAP
bit in TxCTL1 register is set to indicate the timer interrupt is caused by an input
capture event.
If no Capture event occurs, the timer counts up to the 16-bit Compare value stored in the
Timer Reload High and Low Byte registers. Upon reaching the Compare value, the timer
generates an interrupt, the count value in the Timer High and Low Byte registers is reset to
0001H
and counting resumes. The
INPCAP
bit in TxCTL1 register is cleared to indicate
the timer interrupt is not because of an input capture event.
The steps for configuring a timer for CAPTURE/COMPARE mode and initiating the
count are as follows:
1. Write to the Timer Control register to:
Disable the timer
Configure the timer for CAPTURE/COMPARE mode.
Set the prescale value.
Set the Capture edge (rising or falling) for the Timer Input.
2. Write to the Timer High and Low Byte registers to set the starting count value
(typically
0001H
).
3. Write to the Timer Reload High and Low Byte registers to set the Compare value.
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
71
4. Enable the timer interrupt, if appropriate, and set the timer interrupt priority by writing
to the relevant interrupt registers.By default, the timer interrupt are generated for both
input capture and reload events. If appropriate, configure the timer interrupt to be
generated only at the input capture event or the reload event by setting TICONFIG
field of the TxCTL1 register.
5. Configure the associated GPIO port pin for the Timer Input alternate function.
6. Write to the Timer Control register to enable the timer.
7. Counting begins on the first appropriate transition of the Timer Input signal. No
interrupt is generated by this first edge.
In CAPTURE/COMPARE mode, the elapsed time from timer start to Capture event can be
calculated using the following equation:
Reading the Timer Count Values
The current count value in the timers can be read while counting (enabled). This capability
has no effect on timer operation. When the timer is enabled and the Timer High Byte reg-
ister is read, the contents of the Timer Low Byte register are placed in a holding register. A
subsequent read from the Timer Low Byte register returns the value in the holding register.
This operation allows accurate reads of the full 16-bit timer count value while enabled.
When the timers are not enabled, a read from the Timer Low Byte register returns the
actual value in the counter.
Timer Pin Signal Operation
Timer Output is a GPIO Port pin alternate function. The Timer Output is toggled every
time the counter is reloaded.
The timer input can be used as a selectable counting source. It shares the same pin as the
complementary timer output. When selected by the GPIO Alternate Function Registers,
this pin functions as a timer input in all modes except for the DUAL PWM OUTPUT
mode. For this mode, there is no timer input available.
Capture Elapsed Time (s)
Capture Value Start Value
(
) Prescale
System Clock Frequency (Hz)
---------------------------------------------------------------------------------------------------------
=
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
72
Timer Control Register Definitions
Timer 01 High and Low Byte Registers
The Timer 01 High and Low Byte (TxH and TxL) registers (Tables 47 and 49) contain
the current 16-bit timer count value. When the timer is enabled, a read from TxH causes
the value in TxL to be stored in a temporary holding register. A read from TxL always
returns this temporary register when the timers are enabled. When the timer is disabled,
reads from the TxL reads the register directly.
Writing to the Timer High and Low Byte registers while the timer is enabled is not recom-
mended. There are no temporary holding registers available for write operations, so simul-
taneous 16-bit writes are not possible. If either the Timer High or Low Byte registers are
written during counting, the 8-bit written value is placed in the counter (High or Low
Byte) at the next clock edge. The counter continues counting from the new value.
TH and TL--Timer High and Low Bytes
These 2 bytes, {TH[7:0], TL[7:0]}, contain the current 16-bit timer count value.
Timer Reload High and Low Byte Registers
The Timer 01 Reload High and Low Byte (TxRH and TxRL) registers (Tables 49 and 51)
store a 16-bit reload value, {TRH[7:0], TRL[7:0]}. Values written to the Timer Reload
High Byte register are stored in a temporary holding register. When a write to the Timer
Reload Low Byte register occurs, the temporary holding register value is written to the
Timer High Byte register. This operation allows simultaneous updates of the 16-bit Timer
Table 47. Timer 01 High Byte Register (TxH)
BITS
7
6
5
4
3
2
1
0
FIELD
TH
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F00H, F08H
Table 48. Timer 01 Low Byte Register (TxL)
BITS
7
6
5
4
3
2
1
0
FIELD
TL
RESET
0
0
0
0
0
0
0
1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F01H, F09H
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
73
Reload value.
In COMPARE mode, the Timer Reload High and Low Byte registers store the 16-bit
Compare value.
TRH and TRL--Timer Reload Register High and Low
These two bytes form the 16-bit Reload value, {TRH[7:0], TRL[7:0]}. This value sets the
maximum count value which initiates a timer reload to
0001H
. In Compare mode, these
two bytes form the 16-bit Compare value.
Timer 0-1 PWM High and Low Byte Registers
The Timer 0-1 PWM High and Low Byte (TxPWMH and TxPWML) registers (Tables 51
and Table 52) control Pulse-Width Modulator (PWM) operations. These registers also
store the Capture values for the CAPTURE and CAPTURE/COMPARE modes.
Table 49. Timer 01 Reload High Byte Register (TxRH)
BITS
7
6
5
4
3
2
1
0
FIELD
TRH
RESET
1
1
1
1
1
1
1
1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F02H, F0AH
Table 50. Timer 01 Reload Low Byte Register (TxRL)
BITS
7
6
5
4
3
2
1
0
FIELD
TRL
RESET
1
1
1
1
1
1
1
1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F03H, F0BH
Table 51. Timer 01 PWM High Byte Register (TxPWMH)
BITS
7
6
5
4
3
2
1
0
FIELD
PWMH
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F04H, F0CH
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
74
PWMH and PWML--Pulse-Width Modulator High and Low Bytes
These two bytes, {PWMH[7:0], PWML[7:0]}, form a 16-bit value that is compared to the
current 16-bit timer count. When a match occurs, the PWM output changes state. The
PWM output value is set by the TPOL bit in the Timer Control Register (TxCTL1) regis-
ter.
The TxPWMH and TxPWML registers also store the 16-bit captured timer value when
operating in Capture or Capture/Compare modes.
Timer 01 Control Registers
Time 01 Control Register 0
The Timer Control Register 0 (TxCTL0) and Timer Control Register 1 (TxCTL1) deter-
mine the timer operating mode. It also includes a programmable PWM deadband delay,
two bits to configure timer interrupt definition, and a status bit to identify if the most
recent timer interrupt is caused by an input capture event.
TMODEHI--Timer Mode High Bit
This bit along with the TMODE field in TxCTL1 register determines the operating mode
of the timer. This is the most significant bit of the Timer mode selection value. See the
TxCTL1 register description on the next page for additional details.
TICONFIG--Timer Interrupt Configuration
This field configures timer interrupt definition.
Table 52. Timer 01 PWM Low Byte Register (TxPWML)
BITS
7
6
5
4
3
2
1
0
FIELD
PWML
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F05H, F0DH
Table 53. Timer 01 Control Register 0 (TxCTL0)
BITS
7
6
5
4
3
2
1
0
FIELD
TMODEHI
TICONFIG Reserved
PWMD
INPCAP
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F06H, F0EH
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
75
0x = Timer Interrupt occurs on all defined Reload, Compare and Input Events
10 = Timer Interrupt only on defined Input Capture/Deassertion Events
11 = Timer Interrupt only on defined Reload/Compare Events
Reserved--Must be 0.
PWMD--PWM Delay value
This field is a programmable delay to control the number of system clock cycles delay
before the Timer Output and the Timer Output Complement are forced to their active state.
000 = No delay
001 = 2 cycles delay
010 = 4 cycles delay
011 = 8 cycles delay
100 = 16 cycles delay
101 = 32 cycles delay
110 = 64 cycles delay
111 = 128 cycles delay
INPCAP--Input Capture Event
This bit indicates if the most recent timer interrupt is caused by a Timer Input Capture
Event.
0 = Previous timer interrupt is not a result of Timer Input Capture Event
1 = Previous timer interrupt is a result of Timer Input Capture Event
Timer 01 Control Register 1
The Timer 01 Control (TxCTL1) registers enable/disable the timers, set the prescaler
value, and determine the timer operating mode.
TEN--Timer Enable
0 = Timer is disabled.
1 = Timer enabled to count.
TPOL--Timer Input/Output Polarity
Operation of this bit is a function of the current operating mode of the timer.
ONE-SHOT mode
When the timer is disabled, the Timer Output signal is set to the value of this bit.
Table 54. Timer 01 Control Register 1 (TxCTL1)
BITS
7
6
5
4
3
2
1
0
FIELD
TEN
TPOL
PRES
TMODE
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F07H, F0FH
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
76
When the timer is enabled, the Timer Output signal is complemented upon timer
Reload.
CONTINUOUS mode
When the timer is disabled, the Timer Output signal is set to the value of this bit.
When the timer is enabled, the Timer Output signal is complemented upon timer
Reload.
COUNTER mode
When the timer is disabled, the Timer Output signal is set to the value of this bit.
When the timer is enabled, the Timer Output signal is complemented upon timer
Reload.
PWM SINGLE OUTPUT mode
0 = Timer Output is forced Low (0) when the timer is disabled. When enabled, the
Timer Output is forced High (1) upon PWM count match and forced Low (0) upon
Reload.
1 = Timer Output is forced High (1) when the timer is disabled. When enabled, the
Timer Output is forced Low (0) upon PWM count match and forced High (1) upon
Reload.
CAPTURE mode
0 = Count is captured on the rising edge of the Timer Input signal.
1 = Count is captured on the falling edge of the Timer Input signal.
COMPARE mode
When the timer is disabled, the Timer Output signal is set to the value of this bit.
When the timer is enabled, the Timer Output signal is complemented upon timer
Reload.
GATED mode
0 = Timer counts when the Timer Input signal is High (1) and interrupts are generated
on the falling edge of the Timer Input.
1 = Timer counts when the Timer Input signal is Low (0) and interrupts are generated
on the rising edge of the Timer Input.
CAPTURE/COMPARE mode
0 = Counting is started on the first rising edge of the Timer Input signal. The current
count is captured on subsequent rising edges of the Timer Input signal.
1 = Counting is started on the first falling edge of the Timer Input signal. The current
count is captured on subsequent falling edges of the Timer Input signal.
PWM DUAL OUTPUT mode
0 = Timer Output is forced Low (0) and Timer Output Complement is forced High (1)
when the timer is disabled. When enabled, the Timer Output is forced High (1) upon
PWM count match and forced Low (0) upon Reload. When enabled, the Timer Output
Complement is forced Low (0) upon PWM count match and forced High (1) upon
Reload. The PWMD field in TxCTL0 register is a programmable delay to control the
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
77
number of cycles time delay before the Timer Output and the Timer Output
Complement is forced to High (1).
1 = Timer Output is forced High (1) and Timer Output Complement is forced Low (0)
when the timer is disabled. When enabled, the Timer Output is forced Low (0) upon
PWM count match and forced High (1) upon Reload.When enabled, the Timer Output
Complement is forced High (1) upon PWM count match and forced Low (0) upon
Reload. The PWMD field in TxCTL0 register is a programmable delay to control the
number of cycles time delay before the Timer Output and the Timer Output
Complement is forced to Low (0).
CAPTURE RESTART mode
0 = Count is captured on the rising edge of the Timer Input signal.
1 = Count is captured on the falling edge of the Timer Input signal.
COMPARATOR COUNTER mode
When the timer is disabled, the Timer Output signal is set to the value of this bit.
When the timer is enabled, the Timer Output signal is complemented upon timer
Reload.
When the Timer Output alternate function TxOUT on a GPIO port pin is enabled, Tx-
OUT will change to whatever state the TPOL bit is in.The timer does not need to be en-
abled for that to happen. Also, the Port data direction sub register is not needed to be set
to output on TxOUT. Changing the TPOL bit with the timer enabled and running does
not immediately change the TxOUT.
PRES--Prescale value.
The timer input clock is divided by 2
PRES
, where PRES can be set from 0 to 7. The pres-
caler is reset each time the Timer is disabled. This reset ensures proper clock division each
time the Timer is restarted.
000 = Divide by 1
001 = Divide by 2
010 = Divide by 4
011 = Divide by 8
100 = Divide by 16
101 = Divide by 32
110 = Divide by 64
111 = Divide by 128
TMODE--Timer mode
This field along with the TMODEHI bit in TxCTL0 register determines the operating
mode of the timer. TMODEHI is the most significant bit of the Timer mode selection
value.
0000 = One-Shot mode
0001 = Continuous mode
0010 = Counter mode
Caution:
PS024705-0405
P R E L I M I N A R Y Timers
Z8 Encore! XP
F08xA Series
Product Specification
78
0011 = PWM Single Output mode
0100 = Capture mode
0101 = Compare mode
0110 = Gated mode
0111 = Capture/Compare mode
1000 = PWM Dual Output mode
1001 = Capture Restart mode
1010 = Comparator Counter Mode
PS024705-0405
P R E L I M I N A R Y Watch-Dog
Timer
Z8 Encore! XP
F08xA Series
Product Specification
79
Watch-Dog Timer
Overview
The Watch-Dog Timer (WDT) protects against corrupt or unreliable software, power
faults, and other system-level problems which may place the Z8 Encore! XP
F08xA
Series devices into unsuitable operating states. The Watch-Dog Timer includes the follow-
ing features:
On-chip RC oscillator
A selectable time-out response: reset or interrupt
24-bit programmable time-out value
Operation
The Watch-Dog Timer (WDT) is a retriggerable one-shot timer that resets or interrupts the
Z8 Encore! XP
F08xA Series devices when the WDT reaches its terminal count. The
Watch-Dog Timer uses a dedicated on-chip RC oscillator as its clock source. The Watch-
Dog Timer operates in only two modes: ON and OFF. Once enabled, it always counts and
must be refreshed to prevent a time-out. Perform an enable by executing the WDT instruc-
tion or by setting the WDT_AO Flash Option Bit. The WDT_AO bit forces the Watch-
Dog Timer to operate immediately upon reset, even if a WDT instruction has not been
executed.
The Watch-Dog Timer is a 24-bit reloadable downcounter that uses three 8-bit registers in
the eZ8 CPU register space to set the reload value. The nominal WDT time-out period is
described by the following equation:
where the WDT reload value is the decimal value of the 24-bit value given by
{WDTU[7:0], WDTH[7:0], WDTL[7:0]} and the typical Watch-Dog Timer RC oscillator
frequency is 10KHz. The Watch-Dog Timer cannot be refreshed after it reaches
000002H
.
The WDT Reload Value must not be set to values below
000004H
. Table 55 provides
information about approximate time-out delays for the minimum and maximum WDT
reload values.
WDT Time-out Period (ms)
WDT Reload Value
10
--------------------------------------------------
=
PS024705-0405
P R E L I M I N A R Y Watch-Dog
Timer
Z8 Encore! XP
F08xA Series
Product Specification
80
Watch-Dog Timer Refresh
When first enabled, the Watch-Dog Timer is loaded with the value in the Watch-Dog
Timer Reload registers. The Watch-Dog Timer counts down to
000000H
unless a WDT
instruction is executed by the eZ8 CPU. Execution of the WDT instruction causes the
downcounter to be reloaded with the WDT Reload value stored in the Watch-Dog Timer
Reload registers. Counting resumes following the reload operation.
When the Z8 Encore! XP
F08xA Series devices are operating in DEBUG Mode (using
the On-Chip Debugger), the Watch-Dog Timer is continuously refreshed to prevent any
Watch-Dog Timer time-outs.
Watch-Dog Timer Time-Out Response
The Watch-Dog Timer times out when the counter reaches
000000H
. A time-out of the
Watch-Dog Timer generates either an interrupt or a system reset. The WDT_RES Flash
Option Bit determines the time-out response of the Watch-Dog Timer. Refer to the chapter
"Flash Option Bits" on page 138
for information regarding programming of the WDT_RES
Flash Option Bit.
WDT Interrupt in Normal Operation
If configured to generate an interrupt when a time-out occurs, the Watch-Dog Timer issues
an interrupt request to the interrupt controller and sets the WDT status bit in the Watch-Dog
Timer Control register. If interrupts are enabled, the eZ8 CPU responds to the interrupt
request by fetching the Watch-Dog Timer interrupt vector and executing code from the
vector address. After time-out and interrupt generation, the Watch-Dog Timer counter
rolls over to its maximum value of
FFFFFH
and continues counting. The Watch-Dog
Timer counter is not automatically returned to its Reload Value.
The Reset Status Register (page 26) must be read before clearing the WDT interrupt. This
read clears the WDT timeout flag and prevents further WDT interrupts for immediately
occurring.
Table 55. Watch-Dog Timer Approximate Time-Out Delays
WDT Reload Value
(Hex)
WDT Reload Value
(Decimal)
Approximate Time-Out Delay
(with 10KHz typical WDT oscillator frequency)
Typical
Description
000004
4
400
s
Minimum time-out delay
FFFFFF
16,777,215
28 minutes
Maximum time-out delay
PS024705-0405
P R E L I M I N A R Y Watch-Dog
Timer
Z8 Encore! XP
F08xA Series
Product Specification
81
WDT Interrupt in STOP Mode
If configured to generate an interrupt when a time-out occurs and the Z8 Encore! XP
F08xA Series devices are in STOP mode, the Watch-Dog Timer automatically initiates a
STOP Mode Recovery and generates an interrupt request. Both the WDT status bit and the
STOP
bit in the Watch-Dog Timer Control register are set to 1 following a WDT time-out
in STOP mode. Refer to the chapter
"Reset and STOP Mode Recovery" on page 19
for more
information about STOP Mode Recovery.
If interrupts are enabled, following completion of the STOP Mode Recovery the eZ8 CPU
responds to the interrupt request by fetching the Watch-Dog Timer interrupt vector and
executing code from the vector address.
WDT Reset in NORMAL Operation
If configured to generate a Reset when a time-out occurs, the Watch-Dog Timer forces the
device into the System Reset state. The WDT status bit in the Watch-Dog Timer Control
register is set to 1. Refer to the chapter
"Reset and STOP Mode Recovery" on page 19
for
more information about system reset.
WDT Reset in STOP Mode
If configured to generate a Reset when a time-out occurs and the device is in STOP mode,
the Watch-Dog Timer initiates a STOP Mode Recovery. Both the WDT status bit and the
STOP
bit in the Watch-Dog Timer Control register are set to 1 following WDT time-out in
STOP mode. Refer to the chapter
"Reset and STOP Mode Recovery" on page 19
for more
information.
Watch-Dog Timer Reload Unlock Sequence
Writing the unlock sequence to the Watch-Dog Timer (WDTCTL) Control register address
unlocks the three Watch-Dog Timer Reload Byte registers (WDTU, WDTH, and WDTL)
to allow changes to the time-out period. These write operations to the WDTCTL register
address produce no effect on the bits in the WDTCTL register. The locking mechanism
prevents spurious writes to the Reload registers. The following sequence is required to
unlock the Watch-Dog Timer Reload Byte registers (WDTU, WDTH, and WDTL) for
write access.
1. Write 55
H
to the Watch-Dog Timer Control register (WDTCTL).
2. Write AA
H
to the Watch-Dog Timer Control register (WDTCTL).
3. Write the Watch-Dog Timer Reload Upper Byte register (WDTU).
4. Write the Watch-Dog Timer Reload High Byte register (WDTH).
5. Write the Watch-Dog Timer Reload Low Byte register (WDTL).
PS024705-0405
P R E L I M I N A R Y Watch-Dog
Timer
Z8 Encore! XP
F08xA Series
Product Specification
82
All three Watch-Dog Timer Reload registers must be written in the order just listed. There
must be no other register writes between each of these operations. If a register write
occurs, the lock state machine resets and no further writes can occur unless the sequence is
restarted. The value in the Watch-Dog Timer Reload registers is loaded into the counter
when the Watch-Dog Timer is first enabled and every time a WDT instruction is executed.
Watch-Dog Timer Control Register Definitions
Watch-Dog Timer Control Register
The Watch-Dog Timer Control (WDTCTL) register is a write-only control register. Writ-
ing the
55H
,
AAH
unlock sequence to the WDTCTL register address unlocks the three
Watch-Dog Timer Reload Byte registers (WDTU, WDTH, and WDTL) to allow changes
to the time-out period. These write operations to the WDTCTL register address produce
no effect on the bits in the WDTCTL register. The locking mechanism prevents spurious
writes to the Reload registers.
This register address is shared with the read-only Reset Status Register.
WDTUNLK--Watch-Dog Timer Unlock
The user software must write the correct unlocking sequence to this register before it is
allowed to modify the contents of the watch-dog timer reload registers.
Watch-Dog Timer Reload Upper, High and Low Byte Registers
The Watch-Dog Timer Reload Upper, High and Low Byte (WDTU, WDTH, WDTL) reg-
isters (Tables 57 through 59) form the 24-bit reload value that is loaded into the Watch-
Dog Timer when a WDT instruction executes. The 24-bit reload value is {WDTU[7:0],
WDTH[7:0], WDTL[7:0]}. Writing to these registers sets the appropriate Reload Value.
Reading from these registers returns the current Watch-Dog Timer count value.
Table 56. Watch-Dog Timer Control Register (WDTCTL)
BITS
7
6
5
4
3
2
1
0
FIELD
WDTUNLK
RESET
X
X
X
X
X
X
X
X
R/W
W
W
W
W
W
W
W
W
ADDR
FF0H
PS024705-0405
P R E L I M I N A R Y Watch-Dog
Timer
Z8 Encore! XP
F08xA Series
Product Specification
83
The 24-bit WDT Reload Value must not be set to a value less than
000004H
.
WDTU--WDT Reload Upper Byte
Most significant byte (MSB), Bits[23:16], of the 24-bit WDT reload value.
WDTH--WDT Reload High Byte
Middle byte, Bits[15:8], of the 24-bit WDT reload value.
WDTL--WDT Reload Low
Least significant byte (LSB), Bits[7:0], of the 24-bit WDT reload value.
Table 57. Watch-Dog Timer Reload Upper Byte Register (WDTU)
BITS
7
6
5
4
3
2
1
0
FIELD
WDTU
RESET
1
1
1
1
1
1
1
1
R/W
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
ADDR
FF1H
R/W* - Read returns the current WDT count value. Write sets the appropriate Reload Value.
Table 58. Watch-Dog Timer Reload High Byte Register (WDTH)
BITS
7
6
5
4
3
2
1
0
FIELD
WDTH
RESET
1
1
1
1
1
1
1
1
R/W
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
ADDR
FF2H
R/W* - Read returns the current WDT count value. Write sets the appropriate Reload Value.
Table 59. Watch-Dog Timer Reload Low Byte Register (WDTL)
BITS
7
6
5
4
3
2
1
0
FIELD
WDTL
RESET
1
1
1
1
1
1
1
1
R/W
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
ADDR
FF3H
R/W* - Read returns the current WDT count value. Write sets the appropriate Reload Value.
Caution:
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
84
UART
Overview
The Universal Asynchronous Receiver/Transmitter (UART) is a full-duplex communica-
tion channel capable of handling asynchronous data transfers. The UART uses a single
8-bit data mode with selectable parity. Features of the UART include:
8-bit asynchronous data transfer
Selectable even- and odd-parity generation and checking
Option of one or two STOP bits
Separate transmit and receive interrupts
Framing, parity, overrun and break detection
Separate transmit and receive enables
16-bit Baud Rate Generator (BRG)
Selectable MULTIPROCESSOR (9-bit) mode with three configurable interrupt schemes
Baud Rate Generator timer mode
Driver Enable output for external bus transceivers
Architecture
The UART consists of three primary functional blocks: transmitter, receiver, and baud rate
generator. The UART's transmitter and receiver function independently, but employ the
same baud rate and data format. Figure 9 illustrates the UART architecture.
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
85
Figure 9.UART Block Diagram
Operation
Data Format
The UART always transmits and receives data in an 8-bit data format, least-significant bit
first. An even or odd parity bit can be added to the data stream. Each character begins with
an active
Low
Start
bit and ends with either 1 or 2 active High Stop bits. Figures 10 and
11 illustrates the asynchronous data format employed by the UART without parity and
with parity, respectively.
Receive Shifter
Receive Data
Transmit Data
Transmit Shift
TXD
RXD
System Bus
Parity Checker
Parity Generator
Receiver Control
Control Registers
Transmitter Control
CTS
Status Register
Register
Register
Register
Baud Rate
Generator
DE
with Address Compare
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
86
Figure 10.UART Asynchronous Data Format without Parity
Figure 11.UART Asynchronous Data Format with Parity
Transmitting Data using the Polled Method
Follow these steps to transmit data using the polled method of operation:
1. Write to the UART Baud Rate High and Low Byte registers to set the required baud
rate.
2. Enable the UART pin functions by configuring the associated GPIO Port pins for
alternate function operation.
3. Write to the UART Control 1 register, if MULTIPROCESSOR mode is appropriate, to
enable MULTIPROCESSOR (9-bit) mode functions.
4. Set the Multiprocessor Mode Select (MPEN) bit to enable MULTIPROCESSOR mode.
5. Write to the UART Control 0 register to:
Set the transmit enable bit (TEN) to enable the UART for data transmission
Set the parity enable bit (PEN), if parity is appropriate and MULTIPROCESSOR
mode is not enabled, and select either even or odd parity (PSEL).
Set or clear the CTSE bit to enable or disable control from the remote receiver
using the CTS pin.
Start
Bit0
Bit1
Bit2
Bit3
Bit4
Bit5
Bit6
Bit7
Data Field
lsb
msb
Idle State
of Line
Stop Bit(s)
1
2
1
0
Start
Bit0
Bit1
Bit2
Bit3
Bit4
Bit5
Bit6
Bit7
Parity
Data Field
lsb
msb
Idle State
of Line
Stop Bit(s)
1
2
1
0
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
87
6. Check the TDRE bit in the UART Status 0 register to determine if the Transmit Data
register is empty (indicated by a 1). If empty, continue to Step 6. If the Transmit Data
register is full (indicated by a 0), continue to monitor the TDRE bit until the Transmit
Data register becomes available to receive new data.
7. Write the UART Control 1 register to select the outgoing address bit.
8. Set the Multiprocessor Bit Transmitter (MPBT) if sending an address byte, clear it if
sending a data byte.
9. Write the data byte to the UART Transmit Data register. The transmitter automatically
transfers the data to the Transmit Shift register and transmits the data.
10. Make any changes to the Multiprocessor Bit Transmitter (
MPBT
) value, if appropriate
and MULTIPROCESSOR mode is enabled,.
11. To transmit additional bytes, return to Step 5.
Transmitting Data using the Interrupt-Driven Method
The UART Transmitter interrupt indicates the availability of the Transmit Data register to
accept new data for transmission. Follow these steps to configure the UART for interrupt-
driven data transmission:
1. Write to the UART Baud Rate High and Low Byte registers to set the appropriate baud
rate.
2. Enable the UART pin functions by configuring the associated GPIO Port pins for
alternate function operation.
3. Execute a DI instruction to disable interrupts.
4. Write to the Interrupt control registers to enable the UART Transmitter interrupt and
set the acceptable priority.
5. Write to the UART Control 1 register to enable MULTIPROCESSOR (9-bit) mode
functions, if MULTIPROCESSOR mode is appropriate.
6. Set the MULTIPROCESSOR Mode Select (MPEN) to Enable MULTIPROCESSOR
mode.
7. Write to the UART Control 0 register to:
Set the transmit enable bit (TEN) to enable the UART for data transmission
Enable parity, if appropriate and if MULTIPROCESSOR mode is not enabled, and
select either even or odd parity.
Set or clear CTSE to enable or disable control from the remote receiver using the
CTS pin.
8. Execute an EI instruction to enable interrupts.
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
88
The UART is now configured for interrupt-driven data transmission. Because the UART
Transmit Data register is empty, an interrupt is generated immediately. When the UART
Transmit interrupt is detected, the associated interrupt service routine (ISR) performs the
following:
1. Write the UART Control 1 register to select the multiprocessor bit for the byte to be
transmitted:
Set the Multiprocessor Bit Transmitter (MPBT) if sending an address byte, clear it if
sending a data byte.
2. Write the data byte to the UART Transmit Data register. The transmitter automatically
transfers the data to the Transmit Shift register and transmits the data.
3. Clear the UART Transmit interrupt bit in the applicable Interrupt Request register.
4. Execute the IRET instruction to return from the interrupt-service routine and wait for
the Transmit Data register to again become empty.
Receiving Data using the Polled Method
Follow these steps to configure the UART for polled data reception:
5. Write to the UART Baud Rate High and Low Byte registers to set an acceptable baud
rate for the incoming data stream.
6. Enable the UART pin functions by configuring the associated GPIO Port pins for
alternate function operation.
7. Write to the UART Control 1 register to enable MULTIPROCESSOR mode functions,
if appropriate.
8. Write to the UART Control 0 register to:
Set the receive enable bit (REN) to enable the UART for data reception
Enable parity, if appropriate and if Multiprocessor mode is not enabled, and select
either even or odd parity.
9. Check the RDA bit in the UART Status 0 register to determine if the Receive Data
register contains a valid data byte (indicated by a 1). If RDA is set to 1 to indicate
available data, continue to Step 5. If the Receive Data register is empty (indicated by a
0), continue to monitor the RDA bit awaiting reception of the valid data.
10. Read data from the UART Receive Data register. If operating in MULTIPROCESSOR
(9-bit) mode, further actions may be required depending on the MULTIPROCESSOR
mode bits MPMD[1:0].
11. Return to Step 4 to receive additional data.
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
89
Receiving Data using the Interrupt-Driven Method
The UART Receiver interrupt indicates the availability of new data (as well as error condi-
tions). Follow these steps to configure the UART receiver for interrupt-driven operation:
1. Write to the UART Baud Rate High and Low Byte registers to set the acceptable baud
rate.
2. Enable the UART pin functions by configuring the associated GPIO Port pins for
alternate function operation.
3. Execute a DI instruction to disable interrupts.
4. Write to the Interrupt control registers to enable the UART Receiver interrupt and set
the acceptable priority.
5. Clear the UART Receiver interrupt in the applicable Interrupt Request register.
6. Write to the UART Control 1 Register to enable Multiprocessor (9-bit) mode
functions, if appropriate.
Set the Multiprocessor Mode Select (MPEN) to Enable MULTIPROCESSOR
mode.
Set the Multiprocessor Mode Bits, MPMD[1:0], to select the acceptable address
matching scheme.
Configure the UART to interrupt on received data and errors or errors only
(interrupt on errors only is unlikely to be useful for Z8 Encore!
devices without a
DMA block)
7. Write the device address to the Address Compare Register (automatic
MULTIPROCESSOR modes only).
8. Write to the UART Control 0 register to:
Set the receive enable bit (REN) to enable the UART for data reception
Enable parity, if appropriate and if multiprocessor mode is not enabled, and select
either even or odd parity.
9. Execute an EI instruction to enable interrupts.
The UART is now configured for interrupt-driven data reception. When the UART
Receiver interrupt is detected, the associated interrupt service routine (ISR) performs the
following:
1. Checks the UART Status 0 register to determine the source of the interrupt - error,
break, or received data.
2. Reads the data from the UART Receive Data register if the interrupt was because of
data available. If operating in MULTIPROCESSOR (9-bit) mode, further actions may
be required depending on the MULTIPROCESSOR mode bits MPMD[1:0].
3. Clears the UART Receiver interrupt in the applicable Interrupt Request register.
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
90
4. Executes the IRET instruction to return from the interrupt-service routine and await
more data.
Clear To Send (CTS) Operation
The CTS pin, if enabled by the CTSE bit of the UART Control 0 register, performs flow
control on the outgoing transmit datastream. The Clear To Send (CTS) input pin is sam-
pled one system clock before beginning any new character transmission. To delay trans-
mission of the next data character, an external receiver must deassert CTS at least one
system clock cycle before a new data transmission begins. For multiple character trans-
missions, this action is typically performed during Stop Bit transmission. If CTS deasserts
in the middle of a character transmission, the current character is sent completely.
MULTIPROCESSOR (9-bit) Mode
The UART has a MULTIPROCESSOR (9-bit) mode that uses an extra (9th) bit for selec-
tive communication when a number of processors share a common UART bus. In MULTI-
PROCESSOR mode (also referred to as 9-Bit mode), the multiprocessor bit (
MP
) is
transmitted immediately following the 8-bits of data and immediately preceding the Stop
bit(s) as illustrated in Figure 12. The character format is:
Figure 12.UART Asynchronous MULTIPROCESSOR Mode Data Format
In MULTIPROCESSOR (9-bit) mode, the Parity bit location (9th bit) becomes the Multi-
processor control bit. The UART Control 1 and Status 1 registers provide MULTIPRO-
CESSOR (9-bit) mode control and status information. If an automatic address matching
scheme is enabled, the UART Address Compare register holds the network address of the
device.
MULTIPROCESSOR (9-bit) Mode Receive Interrupts
When MULTIPROCESSOR mode is enabled, the UART only processes frames addressed
to it. The determination of whether a frame of data is addressed to the UART can be made
in hardware, software or some combination of the two, depending on the multiprocessor
configuration bits. In general, the address compare feature reduces the load on the CPU,
because it does not require access to the UART when it receives data directed to other
Start
Bit0
Bit1
Bit2
Bit3
Bit4
Bit5
Bit6
Bit7
MP
Data Field
lsb
msb
Idle State
of Line
Stop Bit(s)
1
2
1
0
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
91
devices on the multi-node network. The following three MULTIPROCESSOR modes are
available in hardware:
Interrupt on all address bytes
Interrupt on matched address bytes and correctly framed data bytes
Interrupt only on correctly framed data bytes
These modes are selected with MPMD[1:0] in the UART Control 1 Register. For all mul-
tiprocessor modes, bit MPEN of the UART Control 1 Register must be set to 1.
The first scheme is enabled by writing
01b
to MPMD[1:0]. In this mode, all incoming
address bytes cause an interrupt, while data bytes never cause an interrupt. The interrupt
service routine must manually check the address byte that caused triggered the interrupt. If
it matches the UART address, the software clears MPMD[0]. Each new incoming byte
interrupts the CPU. The software is responsible for determining the end of the frame. It
checks for the end-of-frame by reading the MPRX bit of the UART Status 1 Register for
each incoming byte. If MPRX=1, a new frame has begun. If the address of this new frame
is different from the UART's address, MPMD[0] must be set to 1 causing the UART inter-
rupts to go inactive until the next address byte. If the new frame's address matches the
UART's, the data in the new frame is processed as well.
The second scheme requires the following: set MPMD[1:0] to
10B
and write the UART's
address into the UART Address Compare Register. This mode introduces additional hard-
ware control, interrupting only on frames that match the UART's address. When an
incoming address byte does not match the UART's address, it is ignored. All successive
data bytes in this frame are also ignored. When a matching address byte occurs, an inter-
rupt is issued and further interrupts now occur on each succesive data byte. When the first
data byte in the frame is read, the NEWFRM bit of the UART Status 1 Register is asserted.
All successive data bytes have NEWFRM=0. When the next address byte occurs, the hard-
ware compares it to the UART's address. If there is a match, the interrupts continues and
the NEWFRM bit is set for the first byte of the new frame. If there is no match, the UART
ignores all incoming bytes until the next address match.
The third scheme is enabled by setting MPMD[1:0] to
11b
and by writing the UART's
address into the UART Address Compare Register. This mode is identical to the second
scheme, except that there are no interrupts on address bytes. The first data byte of each
frame remains accompanied by a NEWFRM assertion.
External Driver Enable
The UART provides a Driver Enable (DE) signal for off-chip bus transceivers. This fea-
ture reduces the software overhead associated with using a GPIO pin to control the trans-
ceiver when communicating on a multi-transceiver bus, such as RS-485.
Driver Enable is an active High signal that envelopes the entire transmitted data frame
including parity and Stop bits as illustrated in Figure 13. The Driver Enable signal asserts
when a byte is written to the UART Transmit Data register. The Driver Enable signal
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
92
asserts at least one UART bit period and no greater than two UART bit periods before the
Start bit is transmitted. This allows a setup time to enable the transceiver. The Driver
Enable signal deasserts one system clock period after the final Stop bit is transmitted. This
one system clock delay allows both time for data to clear the transceiver before disabling
it, as well as the ability to determine if another character follows the current character. In
the event of back to back characters (new data must be written to the Transmit Data Regis-
ter before the previous character is completely transmitted) the DE signal is not deasserted
between characters. The Depol bit in the UART Control Register 1 sets the polarity of the
Driver Enable signal.
Figure 13.UART Driver Enable Signal Timing (shown with 1 Stop Bit and Parity)
The Driver Enable to Start bit setup time is calculated as follows:
UART Interrupts
The UART features separate interrupts for the transmitter and the receiver. In addition,
when the UART primary functionality is disabled, the Baud Rate Generator can also func-
tion as a basic timer with interrupt capability.
Transmitter Interrupts
The transmitter generates a single interrupt when the Transmit Data Register Empty bit
(TDRE) is set to 1. This indicates that the transmitter is ready to accept new data for trans-
mission. The TDRE interrupt occurs after the Transmit shift register has shifted the first
bit of data out. The Transmit Data register can now be written with the next character to
send. This action provides 7 bit periods of latency to load the Transmit Data register
before the Transmit shift register completes shifting the current character. Writing to the
UART Transmit Data register clears the TDRE bit to 0.
Start
Bit0
Bit1
Bit2
Bit3
Bit4
Bit5
Bit6
Bit7
Parity
Data Field
lsb
msb
Idle State
of Line
Stop Bit
1
1
0
0
1
DE
1
Baud Rate (Hz)
-------------------------------------
DE to Start Bit Setup Time (s)
2
Baud Rate (Hz)
-------------------------------------
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
93
Receiver Interrupts
The receiver generates an interrupt when any of the following occurs:
A data byte is received and is available in the UART Receive Data register. This interrupt
can be disabled independently of the other receiver interrupt sources. The received data in-
terrupt occurs after the receive character has been received and placed in the Receive Data
register. To avoid an overrun error, software must respond to this received data available
condition before the next character is completely received.
In MULTIPROCESSOR mode (MPEN = 1), the receive data interrupts are dependent on
the multiprocessor configuration and the most recent address byte.
A break is received
An overrun is detected
A data framing error is detected
UART Overrun Errors
When an overrun error condition occurs the UART prevents overwriting of the valid data
currently in the Receive Data register. The Break Detect and Overrun status bits are not
displayed until after the valid data has been read.
After the valid data has been read, the UART Status 0 register is updated to indicate the
overrun condition (and Break Detect, if applicable). The RDA bit is set to 1 to indicate that
the Receive Data register contains a data byte. However, because the overrun error
occurred, this byte may not contain valid data and must be ignored. The BRKD bit indi-
cates if the overrun was caused by a break condition on the line. After reading the status
byte indicating an overrun error, the Receive Data register must be read again to clear the
error bits is the UART Status 0 register. Updates to the Receive Data register occur only
when the next data word is received.
UART Data and Error Handling Procedure
Figure 14 illustrates the recommended procedure for use in UART receiver interrupt ser-
vice routines.
Note:
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
94
Figure 14.UART Receiver Interrupt Service Routine Flow
Baud Rate Generator Interrupts
If the Baud Rate Generator (BRG) interrupt enable is set, the UART Receiver interrupt
asserts when the UART Baud Rate Generator reloads. This condition allows the Baud
Rate Generator to function as an additional counter if the UART functionality is not
employed.
UART Baud Rate Generator
The UART Baud Rate Generator creates a lower frequency baud rate clock for data trans-
mission. The input to the Baud Rate Generator is the system clock. The UART Baud Rate
High and Low Byte registers combine to create a 16-bit baud rate divisor value
Receiver
Errors?
No
Yes
Read Status
Discard Data
Read Data which
Interrupt
Receiver
Ready
clears RDA bit and
resets error bits
Read Data
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
95
(BRG[15:0]) that sets the data transmission rate (baud rate) of the UART. The UART data
rate is calculated using the following equation:
When the UART is disabled, the Baud Rate Generator functions as a basic 16-bit timer
with interrupt on time-out. To configure the Baud Rate Generator as a timer with interrupt
on time-out, complete the following procedure:
1. Disable the UART by clearing the REN and TEN bits in the UART Control 0 register
to 0.
2. Load the acceptable 16-bit count value into the UART Baud Rate High and Low Byte
registers.
3. Enable the Baud Rate Generator timer function and associated interrupt by setting the
BIRQ
bit in the UART Control 1 register to 1.
When configured as a general purpose timer, the interrupt interval is calculated using the
following equation:
Interrupt Interval (s) = System Clock Period (s) BRG[15:0]
]
UART Control Register Definitions
The UART control registers support the UART and the associated Infrared Encoder/
Decoders. For more information about the infrared operation, refer to the
Infrared
Encoder/Decoder
chapter on page 104.
UART Transmit Data Register
Data bytes written to the UART Transmit Data register (Table 60) are shifted out on the
TXDx
pin. The Write-only UART Transmit Data register shares a Register File address
with the read-only UART Receive Data register.
Table 60. UART Transmit Data Register (U0TXD)
BITS
7
6
5
4
3
2
1
0
FIELD
TXD
RESET
X
X
X
X
X
X
X
X
R/W
W
W
W
W
W
W
W
W
ADDR
F40H
UART Data Rate (bits/s)
System Clock Frequency (Hz)
16 UART Baud Rate Divisor Value
----------------------------------------------------------------------------------------------
=
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
96
TXD--Transmit Data
UART transmitter data byte to be shifted out through the TXDx pin.
UART Receive Data Register
Data bytes received through the RXDx pin are stored in the UART Receive Data register
(Table 61). The read-only UART Receive Data register shares a Register File address with
the Write-only UART Transmit Data register.
RXD--Receive Data
UART receiver data byte from the RXDx pin
UART Status 0 Register
The UART Status 0 and Status 1 registers (Table 62 and 54) identify the current UART
operating configuration and status.
RDA--Receive Data Available
This bit indicates that the UART Receive Data register has received data. Reading the
UART Receive Data register clears this bit.
0 = The UART Receive Data register is empty.
1 = There is a byte in the UART Receive Data register.
PE--Parity Error
This bit indicates that a parity error has occurred. Reading the UART Receive Data regis-
ter clears this bit.
Table 61. UART Receive Data Register (U0RXD)
BITS
7
6
5
4
3
2
1
0
FIELD
RXD
RESET
X
X
X
X
X
X
X
X
R/W
R
R
R
R
R
R
R
R
ADDR
F40H
Table 62. UART Status 0 Register (U0STAT0)
BITS
7
6
5
4
3
2
1
0
FIELD
RDA
PE
OE
FE
BRKD
TDRE
TXE
CTS
RESET
0
0
0
0
0
1
1
X
R/W
R
R
R
R
R
R
R
R
ADDR
F41H
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
97
0 = No parity error has occurred.
1 = A parity error has occurred.
OE--Overrun Error
This bit indicates that an overrun error has occurred. An overrun occurs when new data is
received and the UART Receive Data register has not been read. If the RDA bit is reset to
0, reading the UART Receive Data register clears this bit.
0 = No overrun error occurred.
1 = An overrun error occurred.
FE--Framing Error
This bit indicates that a framing error (no Stop bit following data reception) was detected.
Reading the UART Receive Data register clears this bit.
0 = No framing error occurred.
1 = A framing error occurred.
BRKD--Break Detect
This bit indicates that a break occurred. If the data bits, parity/multiprocessor bit, and Stop
bit(s) are all 0s this bit is set to 1. Reading the UART Receive Data register clears this bit.
0 = No break occurred.
1 = A break occurred.
TDRE--Transmitter Data Register Empty
This bit indicates that the UART Transmit Data register is empty and ready for additional
data. Writing to the UART Transmit Data register resets this bit.
0 = Do not write to the UART Transmit Data register.
1 = The UART Transmit Data register is ready to receive an additional byte to be transmit-
ted.
TXE--Transmitter Empty
This bit indicates that the transmit shift register is empty and character transmission is fin-
ished.
0 = Data is currently transmitting.
1 = Transmission is complete.
CTS--CTS signal
When this bit is read it returns the level of the CTS signal. This signal is active Low.
UART Status 1 Register
This register contains multiprocessor control and status bits.
Table 63. UART Status 1 Register (U0STAT1)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
NEWFRM
MPRX
RESET
0
0
0
0
0
0
0
0
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
98
Reserved--Must be 0.
NEWFRM--Status bit denoting the start of a new frame. Reading the UART Receive
Data register resets this bit to 0.
0 = The current byte is not the first data byte of a new frame.
1 = The current byte is the first data byte of a new frame.
MPRX--Multiprocessor Receive
Returns the value of the most recent multiprocessor bit received. Reading from the UART
Receive Data register resets this bit to 0.
UART Control 0 and Control 1 Registers
The UART Control 0 and Control 1 registers (Tables 64 and 65) configure the properties
of the UART's transmit and receive operations. The UART Control registers must not be
written while the UART is enabled.
TEN--Transmit Enable
This bit enables or disables the transmitter. The enable is also controlled by the CTS signal
and the CTSE bit. If the CTS signal is low and the CTSE bit is 1, the transmitter is
enabled.
0 = Transmitter disabled.
1 = Transmitter enabled.
REN--Receive Enable
This bit enables or disables the receiver.
0 = Receiver disabled.
1 = Receiver enabled.
CTSE--CTS Enable
0 = The CTS signal has no effect on the transmitter.
1 = The UART recognizes the CTS signal as an enable control from the transmitter.
R/W
R
R
R
R
R/W
R/W
R
R
ADDR
F44H
Table 64. UART Control 0 Register (U0CTL0)
BITS
7
6
5
4
3
2
1
0
FIELD
TEN
REN
CTSE
PEN
PSEL
SBRK
STOP
LBEN
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F42H
Table 63. UART Status 1 Register (U0STAT1)
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
99
PEN--Parity Enable
This bit enables or disables parity. Even or odd is determined by the PSEL bit.
0 = Parity is disabled.
1 = The transmitter sends data with an additional parity bit and the receiver receives an
additional parity bit.
PSEL--Parity Select
0 = Even parity is transmitted and expected on all received data.
1 = Odd parity is transmitted and expected on all received data.
SBRK--Send Break
This bit pauses or breaks data transmission. Sending a break interrupts any transmission in
progress, so ensure that the transmitter has finished sending data before setting this bit.
0 = No break is sent.
1 = Forces a break condition by setting the output of the transmitter to zero.
STOP--Stop Bit Select
0 = The transmitter sends one stop bit.
1 = The transmitter sends two stop bits.
LBEN--Loop Back Enable
0 = Normal operation.
1 = All transmitted data is looped back to the receiver.
MPMD[1:0]--MULTIPROCESSOR Mode
If MULTIPROCESSOR (9-bit) mode is enabled,
00 = The UART generates an interrupt request on all received bytes (data and address).
01 = The UART generates an interrupt request only on received address bytes.
10 = The UART generates an interrupt request when a received address byte matches the
value stored in the Address Compare Register and on all successive data bytes until an
address mismatch occurs.
11 = The UART generates an interrupt request on all received data bytes for which the
most recent address byte matched the value in the Address Compare Register.
MPEN--MULTIPROCESSOR (9-bit) Enable
This bit is used to enable MULTIPROCESSOR (9-bit) mode.
0 = Disable MULTIPROCESSOR (9-bit) mode.
1 = Enable MULTIPROCESSOR (9-bit) mode.
Table 65. UART Control 1 Register (U0CTL1)
BITS
7
6
5
4
3
2
1
0
FIELD
MPMD[1]
MPEN
MPMD[0]
MPBT
DEPOL
BRGCTL
RDAIRQ
IREN
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F43H
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
100
MPBT--Multiprocessor Bit Transmit
This bit is applicable only when MULTIPROCESSOR (9-bit) mode is enabled. The 9th bit
is used by the receiving device to determine if the data byte contains address or data infor-
mation.
0 = Send a 0 in the multiprocessor bit location of the data stream (data byte).
1 = Send a 1 in the multiprocessor bit location of the data stream (address byte).
DEPOL--Driver Enable Polarity
0 = DE signal is Active High.
1 = DE signal is Active Low.
BRGCTL--Baud Rate Control
This bit causes an alternate UART behavior depending on the value of the REN bit in the
UART Control 0 Register.
When the UART receiver is not enabled (REN=0), this bit determines whether the Baud
Rate Generator issues interrupts.
0 = Reads from the Baud Rate High and Low Byte registers return the BRG Reload Value
1 = The Baud Rate Generator generates a receive interrupt when it counts down to 0.
Reads from the Baud Rate High and Low Byte registers return the current BRG count
value.
When the UART receiver is enabled (REN=1), this bit allows reads from the Baud Rate
Registers to return the BRG count value instead of the Reload Value.
0 = Reads from the Baud Rate High and Low Byte registers return the BRG Reload Value.
1 = Reads from the Baud Rate High and Low Byte registers return the current BRG count
value. Unlike the Timers, there is no mechanism to latch the Low Byte when the High
Byte is read.
RDAIRQ--Receive Data Interrupt Enable
0 = Received data and receiver errors generates an interrupt request to the Interrupt Con-
troller.
1 = Received data does not generate an interrupt request to the Interrupt Controller. Only
receiver errors generate an interrupt request.
IREN--Infrared Encoder/Decoder Enable
0 = Infrared Encoder/Decoder is disabled. UART operates normally.
1 = Infrared Encoder/Decoder is enabled. The UART transmits and receives data through
the Infrared Encoder/Decoder.
UART Address Compare Register
The UART Address Compare register stores the multi-node network address of the UART.
When the MPMD[1] bit of UART Control Register 0 is set, all incoming address bytes are
compared to the value stored in the Address Compare register. Receive interrupts and
RDA assertions only occur in the event of a match.
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
101
COMP_ADDR--Compare Address
This 8-bit value is compared to incoming address bytes.
UART Baud Rate High and Low Byte Registers
The UART Baud Rate High and Low Byte registers (Tables 67 and 68) combine to create
a 16-bit baud rate divisor value (BRG[15:0]) that sets the data transmission rate (baud
rate) of the UART.
The UART data rate is calculated using the following equation:
For a given UART data rate, calculate the integer baud rate divisor value using the follow-
ing equation:
Table 66. UART Address Compare Register (U0ADDR)
BITS
7
6
5
4
3
2
1
0
FIELD
COMP_ADDR
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F45H
Table 67. UART Baud Rate High Byte Register (U0BRH)
BITS
7
6
5
4
3
2
1
0
FIELD
BRH
RESET
1
1
1
1
1
1
1
1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F46H
Table 68. UART Baud Rate Low Byte Register (U0BRL)
BITS
7
6
5
4
3
2
1
0
FIELD
BRL
RESET
1
1
1
1
1
1
1
1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F47H
UART Baud Rate (bits/s)
System Clock Frequency (Hz)
16 UART Baud Rate Divisor Value
----------------------------------------------------------------------------------------------
=
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
102
The baud rate error relative to the acceptable baud rate is calculated using the following
equation:
For reliable communication, the UART baud rate error must never exceed 5 percent.
Table 69 provides information about data rate errors for popular baud rates and commonly
used crystal oscillator frequencies.
Table 69. UART Baud Rates
10.0 MHz System Clock
5.5296 MHz System Clock
Acceptable
Rate (KHz)
BRG Divisor
(Decimal)
Actual Rate
(KHz)
Error
(%)
Acceptable
Rate (KHz)
BRG Divisor
(Decimal)
Actual Rate
(KHz)
Error
(%)
1250.0
N/A
N/A
N/A
1250.0
N/A
N/A
N/A
625.0
1
625.0
0.00
625.0
N/A
N/A
N/A
250.0
3
208.33
-16.67
250.0
1
345.6
38.24
115.2
5
125.0
8.51
115.2
3
115.2
0.00
57.6
11
56.8
-1.36
57.6
6
57.6
0.00
38.4
16
39.1
1.73
38.4
9
38.4
0.00
19.2
33
18.9
0.16
19.2
18
19.2
0.00
9.60
65
9.62
0.16
9.60
36
9.60
0.00
4.80
130
4.81
0.16
4.80
72
4.80
0.00
2.40
260
2.40
-0.03
2.40
144
2.40
0.00
1.20
521
1.20
-0.03
1.20
288
1.20
0.00
0.60
1042
0.60
-0.03
0.60
576
0.60
0.00
0.30
2083
0.30
0.2
0.30
1152
0.30
0.00
UART Baud Rate Divisor Value (BRG)
Round
System Clock Frequency (Hz)
16 UART Data Rate (bits/s)
----------------------------------------------------------------------------
=
UART Baud Rate Error (%)
100
Actual Data Rate Desired Data Rate
Desired Data Rate
-------------------------------------------------------------------------------------------------
=
PS024705-0405
P R E L I M I N A R Y UART
Z8 Encore! XP
F08xA Seriess
Product Specification
103
3.579545 MHz System Clock
1.8432 MHz System Clock
Acceptable
Rate (KHz)
BRG Divisor
(Decimal)
Actual Rate
(KHz)
Error
(%)
Acceptable
Rate (KHz)
BRG Divisor
(Decimal)
Actual Rate
(KHz)
Error
(%)
1250.0
N/A
N/A
N/A
1250.0
N/A
N/A
N/A
625.0
N/A
N/A
N/A
625.0
N/A
N/A
N/A
250.0
1
223.72
-10.51
250.0
N/A
N/A
N/A
115.2
2
111.9
-2.90
115.2
1
115.2
0.00
57.6
4
55.9
-2.90
57.6
2
57.6
0.00
38.4
6
37.3
-2.90
38.4
3
38.4
0.00
19.2
12
18.6
-2.90
19.2
6
19.2
0.00
9.60
23
9.73
1.32
9.60
12
9.60
0.00
4.80
47
4.76
-0.83
4.80
24
4.80
0.00
2.40
93
2.41
0.23
2.40
48
2.40
0.00
1.20
186
1.20
0.23
1.20
96
1.20
0.00
0.60
373
0.60
-0.04
0.60
192
0.60
0.00
0.30
746
0.30
-0.04
0.30
384
0.30
0.00
Table 69. UART Baud Rates (Continued)
PS024705-0405
P R E L I M I N A R Y Infrared
Encoder/Decoder
Z8 Encore! XP
F08xA Series
Product Specification
104
Infrared Encoder/Decoder
Overview
The Z8 Encore! XP
F08xA Series products contain a fully-functional, high-performance
UART to Infrared Encoder/Decoder (Endec). The Infrared Endec is integrated with an on-
chip UART to allow easy communication between the Z8 Encore!
and IrDA Physical
Layer Specification, Version 1.3-compliant infrared transceivers. Infrared communication
provides secure, reliable, low-cost, point-to-point communication between PCs, PDAs,
cell phones, printers and other infrared enabled devices.
Architecture
Figure 15 illustrates the architecture of the Infrared Endec.
Figure 15.Infrared Data Communication System Block Diagram
Operation
When the Infrared Endec is enabled, the transmit data from the associated on-chip UART
is encoded as digital signals in accordance with the IrDA standard and output to the infra-
red transceiver through the TXD pin. Likewise, data received from the infrared transceiver
Interrupt
Signal
RXD
TXD
Infrared
Encoder/Decoder
UART
RxD
TxD
System
Clock
I/O
Address
Data
Infrared
Transceiver
RXD
TXD
Baud Rate
Clock
(Endec)
PS024705-0405
P R E L I M I N A R Y Infrared
Encoder/Decoder
Z8 Encore! XP
F08xA Series
Product Specification
105
is passed to the Infrared Endec through the RXD pin, decoded by the Infrared Endec, and
passed to the UART. Communication is half-duplex, which means simultaneous data
transmission and reception is not allowed.
The baud rate is set by the UART's Baud Rate Generator and supports IrDA standard baud
rates from 9600 baud to 115.2 Kbaud. Higher baud rates are possible, but do not meet
IrDA specifications. The UART must be enabled to use the Infrared Endec. The Infrared
Endec data rate is calculated using the following equation:
:
Transmitting IrDA Data
The data to be transmitted using the infrared transceiver is first sent to the UART. The
UART's transmit signal (TXD) and baud rate clock are used by the IrDA to generate the
modulation signal (IR_TXD) that drives the infrared transceiver. Each UART/Infrared
data bit is 16 clocks wide. If the data to be transmitted is 1, the IR_TXD signal remains
low for the full 16 clock period. If the data to be transmitted is 0, the transmitter first out-
puts a 7 clock low period, followed by a 3 clock high pulse. Finally, a 6 clock low pulse is
output to complete the full 16 clock data period. Figure 16 illustrates IrDA data transmis-
sion. When the Infrared Endec is enabled, the UART's TXD signal is internal to the Z8
Encore! XP
F08xA Series products while the IR_TXD signal is output through the TXD
pin.
Figure 16.Infrared Data Transmission
Infrared
Data Rate (bits/s)
System Clock Frequency (Hz)
16 UART Baud Rate Divisor Value
----------------------------------------------------------------------------------------------
=
Baud Rate
IR_TXD
UART's
16 clock
period
Start Bit = 0
Data Bit 0 = 1
Data Bit 1 = 0
Data Bit 2 = 1
Data Bit 3 = 1
7-clock
delay
3 clock
pulse
TXD
Clock
PS024705-0405
P R E L I M I N A R Y Infrared
Encoder/Decoder
Z8 Encore! XP
F08xA Series
Product Specification
106
Receiving IrDA Data
Data received from the infrared transceiver using the IR_RXD signal through the RXD pin
is decoded by the Infrared Endec and passed to the UART. The UART's baud rate clock is
used by the Infrared Endec to generate the demodulated signal (RXD) that drives the
UART. Each UART/Infrared data bit is 16-clocks wide. Figure 17 illustrates data recep-
tion. When the Infrared Endec is enabled, the UART's RXD signal is internal to the Z8
Encore! XP
F08xA Series products while the IR_RXD signal is received through the
RXD pin.
Figure 17.IrDA Data Reception
Infrared Data Reception
The system clock frequency must be at least 1.0MHz to ensure proper reception of the
1.4
s minimum width pulses allowed by the IrDA standard.
Endec Receiver Synchronization
The IrDA receiver uses a local baud rate clock counter (0 to 15 clock periods) to generate
an input stream for the UART and to create a sampling window for detection of incoming
pulses. The generated UART input (UART RXD) is delayed by 8 baud rate clock periods
with respect to the incoming IrDA data stream. When a falling edge in the input data
stream is detected, the Endec counter is reset. When the count reaches a value of 8, the
UART RXD value is updated to reflect the value of the decoded data. When the count
reaches 12 baud clock periods, the sampling window for the next incoming pulse opens.
The window remains open until the count again reaches 8 (in other words, 24 baud clock
periods since the previous pulse was detected), giving the Endec a sampling window of
Baud Rate
UART's
IR_RXD
16 clock
period
Start Bit = 0
Data Bit 0 = 1
Data Bit 1 = 0
Data Bit 2 = 1
Data Bit 3 = 1
8 clock
delay
Clock
RXD
16 clock
period
16 clock
period
16 clock
period
16 clock
period
Start Bit = 0
Data Bit 0 = 1
Data Bit 1 = 0
Data Bit 2 = 1
Data Bit 3 = 1
min. 1.4
s
pulse
Caution:
PS024705-0405
P R E L I M I N A R Y Infrared
Encoder/Decoder
Z8 Encore! XP
F08xA Series
Product Specification
107
minus four baud rate clocks to plus eight baud rate clocks around the expected time of an
incoming pulse. If an incoming pulse is detected inside this window this process is
repeated. If the incoming data is a logical 1 (no pulse), the Endec returns to the initial state
and waits for the next falling edge. As each falling edge is detected, the Endec clock
counter is reset, resynchronizing the Endec to the incoming signal, allowing the Endec to
tolerate jitter and baud rate errors in the incoming datastream. Resynchronizing the Endec
does not alter the operation of the UART, which ultimately receives the data. The UART is
only synchronized to the incoming data stream when a Start bit is received.
Infrared Encoder/Decoder Control Register Definitions
All Infrared Endec configuration and status information is set by the UART control regis-
ters as defined beginning on page 84.
To prevent spurious signals during IrDA data transmission, set the IREN bit in the
UART Control 1 register to 1 to enable the Infrared Encoder/Decoder before enabling
the GPIO Port alternate function for the corresponding pin.
Caution:
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
108
Analog-to-Digital Converter
Overview
The Analog-to-Digital Converter (ADC) converts an analog input signal to its digital rep-
resentation. The features of this sigma-delta ADC include:
11-bit resolution in DIFFERENTIAL mode
10-bit resolution in SINGLE-ENDED mode
8 single-ended analog input sources are multiplexed with general-purpose I/O ports
9th analog input obtained from temperature sensor peripheral
11 pairs of differential inputs also multiplexed with general-purpose I/O ports
Differential input gain with two selectable values: unity and 20x
Transimpedance amplifier for current measurements
Interrupt upon conversion complete
Interrupt on sample value greater than programmable high threshold
Interrupt on sample value smaller than programmable low threshold
Internal voltage reference generator with three selectable levels
Manual in-circuit calibration is possible employing user code (offset calibration)
Architecture
Figure 18 illustrates the major functional blocks of the ADC. An analog multiplexer net-
work selects the ADC input from the available analog pins, ANA0 through ANA7.
The input stage of the ADC allows both differential gain and buffering. The following
input options are available:
Unbuffered input (Single-ended and Differential modes)
Buffered input with unity gain (SINGLE-ENDED and DIFFERENTIAL modes)
Buffered input with 20x gain (DIFFERENTIAL mode only)
Transimpedance mode with full pin access to the feedback path
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
109
Figure 18.Analog-to-Digital Converter Block Diagram
Operation
Data Format
In both SINGLE-ENDED and DIFFERENTIAL modes, the output of the ADC is an 11-
bit, signed, two's complement digital value. In DIFFERENTIAL mode, the ADC can out-
Temp
Analog Input
Multiplexer
Internal Voltage
Reference Generator
Analog In +
Ref Input
Sensor
Analog In -
+
-
VREF pin
ADC
IRQ
ADC
Data
11 bit
Sigma-Delta
ADC
Vrefsel
2
11
Analog Input
Multiplexer
ANA7
ANA6
ANA5
ANA4
ANA3
ANA2
ANA1
ANA0
ANA5
ANA4
ANA3
ANA2
ANA1
ANA0
for offs
e
t
cal
i
brat
ion
ANAIN
4
Amplifier with
Configurable Gain
and Buffering
+
-
Transimpedance
Amplifier
BUFFMODE
VREFEXT
Amplifier tristates
when disabled
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
110
put values across the entire 11-bit range, from -1024 to +1023. In SINGLE-ENDED mode,
the output generally ranges from 0 to +1023, but offset errors can cause small negative
values.
The ADC registers return 13 bits of data, but the two LSBs are intended for compensation
use only. When the compensation routine is performed on the 13 bit raw ADC value, two
bits of resolution are lost because of a rounding error. As a result, the final value is an 11-
bit number.
Automatic Powerdown
If the ADC is idle (no conversions in progress) for 160 consecutive system clock cycles,
portions of the ADC are automatically powered down. From this powerdown state, the
ADC requires 40 system clock cycles to powerup. The ADC powers up when a conversion
is requested by the ADC Control register.
Single-Shot Conversion
When configured for single-shot conversion, the ADC performs a single analog-to-digital
conversion on the selected analog input channel. After completion of the conversion, the
ADC shuts down. The steps for setting up the ADC and initiating a single-shot conversion
are as follows:
1. Enable the acceptable analog inputs by configuring the general-purpose I/O pins for
alternate function. This configuration disables the digital input and output drivers.
2. Write the
ADC High Threshold Register
and
ADC Low Threshold Register
if the alarm
function is required.
3. Write the
ADC Control/Status Register 1
to configure the ADC
Write to BUFMODE[2:0] to select SINGLE-ENDED or DIFFERENTIAL mode,
as well as unbuffered, buffered, 20x buffered gain (in DIFFERENTIAL mode
only) or TRANSIMPEDANCE mode
If the alarm function is required, set
ALMHEN
and/or
ALMLEN
Write the
REFSELH
bit of the pair {
REFSELH
,
REFSELL
} to select the internal
voltage reference level or to disable the internal reference. The
REFSELH
bit is
contained in the
ADC Control/Status Register 1
.
4. Write to the
ADC Control Register 0
to configure the ADC and begin the conversion.
The bit fields in the ADC Control register can be written simultaneously:
Write to the ANAIN[3:0] field to select from the available analog input sources
(different input pins available depending on the device)
Clear CONT to 0 to select a single-shot conversion.
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
111
If the internal voltage reference must be output to a pin, set the
REFEXT
bit to 1.
The internal voltage reference must be enabled in this case.
Write the REFSELL bit of the pair {
REFSELH
,
REFSELL
} to select the internal
voltage reference level or to disable the internal reference. The REFSELL bit is
contained in the
ADC Control Register 0
.
Set CEN to 1 to start the conversion.
5. CEN remains 1 while the conversion is in progress. A single-shot conversion requires
5129 system clock cycles to complete. If a single-shot conversion is requested from an
ADC powered-down state, the ADC uses 40 additional clock cycles to power-up
before beginning the 5129 cycle conversion.
6. When the conversion is complete, the ADC control logic performs the following
operations:
11-bit two's-complement result written to {ADCD_H[7:0], ADCD_L[7:5]}.
CEN
resets to 0 to indicate the conversion is complete.
If the High and Low alarms are disabled, an interrupt request is sent to the
Interrupt Controller denoting conversion complete.
If the High alarm is enabled and the ADC value is higher than the alarm threshold,
an interrupt is generated.
If the Low alarm is enabled and the ADC value is lower than the alarm threshold,
an interrupt is generated.
7. If the ADC remains idle for 160 consecutive system clock cycles, it is automatically
powered-down.
Continuous Conversion
When configured for continuous conversion, the ADC continuously performs an analog-
to-digital conversion on the selected analog input. Each new data value over-writes the
previous value stored in the ADC Data registers. An interrupt is generated after each con-
version.
In CONTINUOUS mode, ADC updates are limited by the input signal bandwidth of the
ADC and the latency of the ADC and its digital filter. Step changes at the input are not
detected at the next output from the ADC. The response of the ADC (in all modes) is
limited by the input signal bandwidth and the latency.
Follow these steps for setting up the ADC and initiating continuous conversion:
1. Enable the acceptable analog input by configuring the general-purpose I/O pins for
alternate function. This action disables the digital input and output driver.
2. Write the
ADC High Threshold Register
and
ADC Low Threshold Register
if the alarm
function is required.
Caution:
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
112
3. Write the
ADC Control/Status Register 1
to configure the ADC
Write to
BUFMODE
[2:0] to select SINGLE-ENDED or DIFFERENTIAL mode, as
well as unbuffered, buffered, 20x buffered gain (in differential mode only) or
transimpedance mode
If the alarm function is required, set
ALMHEN
and/or
ALMLEN
Write the
REFSELH
bit of the pair {
REFSELH
,
REFSELL
} to select the internal
voltage reference level or to disable the internal reference. The REFSELH bit is
contained in the
ADC Control/Status Register 1
.
4. Write to the
ADC Control Register 0
to configure the ADC for continuous conversion.
The bit fields in the ADC Control register may be written simultaneously:
Write to the ANAIN[3:0] field to select from the available analog input sources
(different input pins available depending on the device)
Set CONT to 1 to select continuous conversion.
If the internal VREF must be output to a pin, set the REFEXT bit to 1. The
internal voltage reference must be enabled in this case.
Write the REFSELL bit of the pair {REFSELH, REFSELL} to select the internal
voltage reference level or to disable the internal reference. The REFSELL bit is
contained in
ADC Control Register 0
.
Set CEN to 1 to start the conversions.
5. When the first conversion in continuous operation is complete (after 5129 system
clock cycles, plus the 40 cycles for power-up, if necessary), the ADC control logic
performs the following operations:
CEN
resets to 0 to indicate the first conversion is complete. CEN remains 0 for all
subsequent conversions in continuous operation.
An interrupt request is sent to the Interrupt Controller to indicate the conversion is
complete.
6. The ADC writes a new data result every 256 system clock cycles. For each completed
conversion, the ADC control logic performs the following operations:
Writes the 11-bit two's complement result to {ADCD_H[7:0], ADCD_L[7:5]}.
If the high and low alarms are disabled, sends an interrupt request to the Interrupt
Controller denoting conversion complete.
If the high alarm is enabled and the ADC value is higher than the alarm threshold,
generates an interrupt.
If the low alarm is enabled and the ADC value is lower than the alarm threshold,
generates an interrupt.
7. To disable continuous conversion, clear the CONT bit in the ADC Control Register
to 0.
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
113
Programmable Trigger Point Alarm
The ADC contains two programmable trigger values, a high and a low. Each of these val-
ues is 8 bits and is NOT a two's complement number. The alarm is intended primarily for
single ended operation and so the alarm values reflect positive numbers only. Both thresh-
olds have independent control and status bits.
When enabled and the ADC bits exceed the high threshold, an ADC interrupt is asserted
and the high threshold status bit is set. When enabled and the ADC bits are less than the
low threshold, an ADC interrupt is asserted and the low threshold status bit is set.
Because the alarm value is positive it is compared to the most significant 8 data bits of the
ADC values, excluding the sign bit. The ADC alarm bits are compared to
{ADCD_H[6:0],ADCD_L[7]}. Alternatively, the alarm value is compared to the ADC
value shifted left by one bit. Negative ADC values never trigger the high alarm and always
trigger the low alarm. Because the ADC output is software compensated for offset, nega-
tive (pre-compensated) values can occur in SINGLE-ENDED mode.
The alarm is used in CONTINUOUS mode, in which it no longer is required to service an
interrupt for each ADC sample. If used in SINGLE-SHOT mode, the ADC never inter-
rupts the CPU unless the single sample triggers an alarm.
The alarm status bits are updated on each conversion, regardless of the alarm enable bit
values. The alarm enable bits only determine whether or not an interrupt is generated.
Interrupts
The ADC is able to interrupt the CPU under three conditions:
When a conversion has been completed
When the 8 Most Significant Bits of a sample exceed the programmable high threshold
ADCTHI[7:0]
When the 8 Most Significant Bits of a sample is less than the programmable low threshold
ADCTLO[7:0]
The conversion interrupt occurs when the ADC is enabled and both alarms are disabled.
When either or both alarms are enabled, the conversion interrupt is disabled and only the
alarm interrupts occur.
When the ADC is disabled, none of the three sources cause an interrupt to be asserted;
however, an interrupt pending when the ADC is disabled is not cleared.
The three interrupt events share a common CPU interrupt. The interrupt service routine
must query the ADC status register to determine the cause of an ADC interrupt. The regis-
ter bits denoting ADC alarm status can only be set by hardware and are cleared by writing
a 1.
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
114
Calibration and Compensation
The Z8 Encore! XP
F08xA Series ADC can be factory calibrated for offset error and gain
error, with the compensation data stored in Flash memory. Alternatively, user code can
perform its own calibration, storing the values into Flash themselves. Thirdly, the user
code can perform a manual offset calibration during DIFFERENTIAL mode operation.
Factory Calibration
Devices that have been factory calibrated contain 30 bytes of calibration data in the Flash
option bit space. This data consists of 3 bytes for each input mode. See "ZiLOG Calibra-
tion Bits" on page 145. There is 1 byte for offset, 2 bytes for gain correction.
User Calibration
If the user has precision references available, its own external calibration can be per-
formed using any of the three available input modes. Because the calibration data consid-
ers buffer offset and non-linearity, it is recommended that this calibration be performed
separately for each of the ADC input modes planned for use.
Manual Offset Calibration
When uncalibrated, the ADC has significant offset (up to 35 mV with unity gain and up to
250 mV in 20x gain mode). Subsequently, manual offset calibration capability is built into
the block. When the
ADC Control Register 0
sets the input mode (ANAIN[2:0]) to MAN-
UAL OFFSET CALIBRATION mode, the differential inputs to the ADC are shorted
together by an internal switch. Reading the ADC value at this point produces 0 in an ideal
system. The value actually read is the ADC offset. This value can be stored in flash and
accessed by user code to compensate for the input offset error.
There is no provision for manual gain calibration.
Software Compensation Procedure
The value read from the ADC high and low byte registers are uncompensated. The user
mode software must apply gain and offset correction to this uncompensated value for
maximum accuracy. The following formula yields the compensated value:
ADC
comp
= (ADC
uncomp
- OFFCAL) + ((ADC
uncomp
- OFFCAL)*GAINCAL)/2
16
where GAINCAL is the gain calibration byte, OFFCAL is the offset calibration byte and
ADC
uncomp
is the uncompensated value read from the ADC. The OFFCAL value is in
two's complement format, as are the compensated and uncompensated ADC values.
The offset compensation is performed first, followed by the gain compensation. One bit of
resolution is lost because of rounding on both the offset and gain computations. As a result
the ADC registers read back 13 bits: 1 sign bit, two calibration bits lost to rounding and 10
data bits.
Note:
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
115
Also note that in the second term, the multiplication should be performed before the divi-
sion by 2
16
. Otherwise, the second term will incorrectly evaluate to zero.
Although the ADC can be used without the gain and offset compensation, it does exhibit
non-unity gain. Designing the ADC with sub-unity gain reduces noise across the ADC
range but requires the ADC results to be scaled by a factor of 8/7.
Input Buffer Stage
Many applications require the measurement of an input voltage source with a high output
impedance. This ADC provides a buffered input for such situations. The drawback of the
buffered input is a limitation of the input range. When using unity gain buffered mode, the
input signal must be prevented from coming within 300mV of V
SS
and 400mV of V
DD
.
Very small input voltages (less than 300mV) may not be measured in BUFFERED mode.
This condition applies only to the input voltage level (with respect to ground) of each dif-
ferential input signal. The actual differential input voltage magnitude may be less than 300
mV.
The 20x gain mode has more complicated input signal requirements. Similar to the unity
gain buffered mode, both inputs must be prevented from coming within 300mV of either
supply. Because of the limitations in the output swing of the 20x gain stage, the following
additional constraints apply:
430 mV < 10 (V
inp
- V
inn
) + V
cm
< V
DD
- 430mV
430 mV < 10 (V
inn
- V
inp
) + V
cm
< V
DD
- 430mV
where
V
cm
= (V
inp
- V
inn
)/2 (common mode voltage),
V
inp
is the positive ADC input voltage,
V
inn
is the negative ADC input voltage
These differential mode limitations explain that the common mode voltage of the differen-
tial inputs must be significantly above ground and below the supply, and that the differen-
tial magnitude must exceed these limitations.
The input range of the unbuffered ADC swings from V
SS
to V
DD
. Input signals smaller
than 300mV must use the unbuffered input mode. If these signals do not contain low out-
put impedances, they might require off-chip buffering.
Signals outside the allowable input range can be used without instability or device dam-
age. Any ADC readings made outside the input range are subject to greater inaccuracy
than specified.
Caution:
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
116
Transimpedance Amplifier
The transimpedance amplifier is a standard operational amplifier designed for current
measurements. Each of the three ports of the amplifier is accessible from the package pins.
The inverting input is commonly used to connect to the current source. The output node
connects an external feedback network to the inverting input. The non-inverting output is
required to apply a non-zero bias point. In a standard, single-supply system, this bias point
must be substantially above ground to measure positive input currents. The non-inverting
input may also be used for offset correction.
The transimpedance amplifier contains only one pin configuration: ANA0 is the output/
feedback node, ANA1 is the inverting input and ANA2 is the non-inverting input.
To use the transimpedance amplifier, it must be enabled in the
Power Control Register 0
(PWRCTL0)
. The default state of the transimpedance amplifier is OFF. To use the transim-
pedance amplifier, the TRAM bit must be cleared, turning it ON (
"Power Control Register
0 (PWRCTL0)" on page 30
). When making normal ADC measurements on ANA0 (not tran-
simpedance measurements), the TRAM bit must be OFF. Turning the TRAM bit ON inter-
feres with normal ADC measurements. Finally, this bit enables the amplifier even in
STOP mode. If the amplifier is not required in STOP mode, disable it. Failing to perform
this results in STOP mode currents greater than specified.
As with other ADC measurements, any pins used for analog purposes must be configured
as such in the GPIO registers (see
"Port AD Alternate Function Sub-Registers" on
page 39
).
Standard transimpedance measurements are made on ANA0, as selected by the
ANAIN[3:0] bits of
ADC Control Register 0
. It is also possible to make single-ended mea-
surements on ANA1 and ANA2 while the amplifier is enabled, which is often useful for
determining offset conditions.
The
BUFFMODE
[2:0] bits of
ADC Control/Status Register 1
must also be configured for sin-
gle-ended, unity-gain buffered operation. Using the transimpedance amplifier in an unbuf-
fered or differential mode is not recommended.
When either input is overdriven, the amplifier output saturates at the positive or negative
supply voltage. No instability results.
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
117
ADC Control Register Definitions
ADC Control Register 0
The ADC Control register selects the analog input channel and initiates the analog-to-dig-
ital conversion.
CEN--Conversion Enable
0 = Conversion is complete. Writing a 0 produces no effect. The ADC automatically clears
this bit to 0 when a conversion is complete.
1 = Begin conversion. Writing a 1 to this bit starts a conversion. If a conversion is already
in progress, the conversion restarts. This bit remains 1 until the conversion is complete.
REFSELL--Voltage Reference Level Select Low Bit; in conjunction with the High bit
(REFSELH) in
ADC Control/Status Register 1
, this determines the level of the internal volt-
age reference; the following details the effects of {REFSELH, REFSELL}; note that this
reference is independent of the Comparator reference
00= Internal Reference Disabled, reference comes from external pin
01= Internal Reference set to 1.0 V
10= Internal Reference set to 2.0 V (default)
11= Reserved
REFEXT
-
External Reference Select
0 = External reference buffer is disabled; Vref pin is available for GPIO functions
1 = The internal ADC reference is buffered and connected to the Vref pin
CONT
0 = Single-shot conversion. ADC data is output once at completion of the 5129 system
clock cycles
1 = Continuous conversion. ADC data updated every 256 system clock cycles
ANAIN[3:0]--Analog Input Select
These bits select the analog input for conversion. Not all Port pins in this list are available
in all packages for the Z8 Encore! XP
F08xA Series. Refer to the chapter
"Pin Descrip-
tion" on page 7
for information regarding the Port pins available with each package style.
Do not enable unavailable analog inputs. Usage of these bits changes depending on the
buffer mode selected in
ADC Control/Status Register 1
.
Table 70. ADC Control Register 0 (ADCCTL0)
BITS
7
6
5
4
3
2
1
0
FIELD
CEN
REFSELL
REFEXT
CONT
ANAIN[3:0]
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F70H
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
118
For the reserved values, all input switches are disabled to avoid leakage or other undesir-
able operation. ADC samples taken with reserved bit settings are undefined.
Single-Ended:
0000 = ANA0 (transimpedance amp output when enabled)
0001 = ANA1 (transimpedance amp inverting input)
0010 = ANA2 (transimpedance amp non-inverting input)
0011 = ANA3
0100 = ANA4
0101 = ANA5
0110 = ANA6
0111 = ANA7
1000 = Reserved
1001 = Reserved
1010 = Reserved
1011 = Reserved
1100 = Hold transimpedance input nodes (ANA1 and ANA2) to ground.
1101 = Reserved
1110 = Temperature Sensor.
1111 = Manual Offset Calibration Mode.
Differential (non-inverting input and inverting input respectively):
0000 = ANA0 and ANA1
0001 = ANA2 and ANA3
0010 = ANA4 and ANA5
0011 = ANA1 and ANA0
0100 = ANA3 and ANA2
0101 = ANA5 and ANA4
0110 = ANA6 and ANA5
0111 = ANA0 and ANA2
1000 = ANA0 and ANA3
1001 = ANA0 and ANA4
1010 = ANA0 and ANA5
1011 = Reserved
1100 = Reserved
1101 = Reserved
1110 = Reserved
1111 = Manual Offset Calibration Mode
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
119
ADC Control/Status Register 1
The second ADC Control register configures the input buffer stage, enables the threshold
interrupts and contains the status of both threshold triggers.
REFSELH--Voltage Reference Level Select High Bit; in conjunction with the Low bit
(REFSELL) in
ADC Control Register 0
, this determines the level of the internal voltage ref-
erence; the following details the effects of {REFSELH, REFSELL}; this reference is inde-
pendent of the Comparator reference
00= Internal Reference Disabled, reference comes from external pin
01= Internal Reference set to 1.0 V
10= Internal Reference set to 2.0 V (default)
11= Reserved
ALMHST--Alarm High Status; this bit can only be set by hardware and must be written
with a 1 to clear
0= No alarm occurred.
1= A high threshold alarm occurred.
ALMLST--Alarm Low Status; this bit can only be set by hardware and must be written
with a 1 to clear
0= No alarm occurred.
1= A low threshold alarm occurred.
ALMHEN--Alarm High Enable
0= Alarm interrupt for high threshold is disabled. The alarm status bit remains set when
the alarm threshold is passed.
1= High threshold alarm interrupt is enabled.
ALMLEN--Alarm Low Enable
0= Alarm interrupt for low threshold is disabled. The alarm status bit remains set when the
alarm threshold is passed.
1= Low threshold alarm interrupt is enabled.
BUFMODE[2:0]
-
Input Buffer Mode Select
000 = Single-ended, unbuffered input
001 = Single-ended, buffered input with unity gain
010 = Reserved
011 = Reserved
Table 71. ADC Control/Status Register 1 (ADCCTL1)
BITS
7
6
5
4
3
2
1
0
FIELD
REFSELH ALMHST
ALMLST
ALMHEN
ALMLEN
BUFMODE[2:0]
RESET
1
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F71H
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
120
100 = Differential, unbuffered input
101 = Differential, buffered input with unity gain
110 = Reserved
111 = Differential, buffered input with 20x gain
ADC Data High Byte Register
The ADC Data High Byte register contains the upper eight bits of the ADC output. The
output is an 11-bit two's complement value. During a single-shot conversion, this value is
invalid. Access to the ADC Data High Byte register is read-only. Reading the ADC Data
High Byte register latches data in the ADC Low Bits register.
ADCDH--ADC Data High Byte
This byte contains the upper eight bits of the ADC output. These bits are not valid during a
single-shot conversion. During a continuous conversion, the most recent conversion out-
put is held in this register. These bits are undefined after a Reset.
ADC Data Low Bits Register
The ADC Data Low Byte register contains the lower bits of the ADC output as well as an
overflow status bit. The output is a 11-bit two's complement value. During a single-shot
conversion, this value is invalid. Access to the ADC Data Low Byte register is read-only.
Reading the ADC Data High Byte register latches data in the ADC Low Bits register.
ADCDL--ADC Data Low Bits
These bits are the least significant three bits of the 11-bits of the ADC output. These bits
are undefined after a Reset.
Table 72. ADC Data High Byte Register (ADCD_H)
BITS
7
6
5
4
3
2
1
0
FIELD
ADCDH
RESET
X
X
X
X
X
X
X
X
R/W
R
R
R
R
R
R
R
R
ADDR
F72H
Table 73. ADC Data Low Bits Register (ADCD_L)
BITS
7
6
5
4
3
2
1
0
FIELD
ADCDL
Reserved
OVF
RESET
X
X
X
X
X
X
X
X
R/W
R
R
R
R
R
R
R
R
ADDR
F73H
PS024705-0405
P R E L I M I N A R Y Analog-to-Digital
Converter
Z8 Encore! XP
F08xA Series
Product Specification
121
Reserved--Must be undefined.
OVF--Overflow Status
0= An overflow did not occur in the digital filter for the current sample.
1= An overflow did occur in the digital filter for the current sample.
ADC High Threshold Register
The ADC High Threshold register is used to set the trigger point above which an ADC
sample causes a CPU interrupt.
ADCTH--ADC High Threshold
These bits are compared to the most significant 8 bits of the single-ended ADC value. If
the ADC value exceeds this, an interrupt is asserted. The alarm function is not available in
DIFFERENTIAL mode.
ADC Low Threshold Register
The ADC Low Threshold register is used to set the trigger point below which an ADC
sample causes a CPU interrupt.
ADCTL--ADC Low Threshold
These bits are compared to the most significant 8 bits of the single-ended ADC value. If
the ADC value drops below this value an interrupt is asserted. The alarm function is not
available in DIFFERENTIAL mode.
Table 74. ADC High Threshold High Byte (ADCTH)
BITS
7
6
5
4
3
2
1
0
FIELD
ADCTH
RESET
FF
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F74H
Table 75. ADC Low Threshold High Byte (ADCTL)
BITS
7
6
5
4
3
2
1
0
FIELD
ADCTL
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F76H
PS024705-0405
P R E L I M I N A R Y Comparator
Z8 Encore! XP
F08xA Series
Product Specification
122
Comparator
Overview
The Z8 Encore! XP
F08xA Series devices feature a general purpose comparator that
compares two analog input signals. A GPIO (
CINP
) pin provides the positive comparator
input. The negative input (
CINN
) may be taken from either an external GPIO pin or an
internal reference. The output is available as an interrupt source or can be routed to an
external pin using the GPIO multiplex. Features include:
2 inputs which can be connected up using the GPIO multiplex (MUX)
1 input can be connected to a programmable internal reference
1 input can be connected to the on-chip temperature sensor
Output can be either an interrupt source or an output to an external pin
Operation
One of the comparator inputs may be connected to an internal reference which is a user
selectable reference that is user programmable with 200 mV resolution.
The comparator may be powered down to save on supply current. See the
Power Control
Register 0
on page 29 for details.
Because of the propagation delay of the comparator, it is not recommended to enable the
comparator without first disabling interrupts and waiting for the comparator output to
settle. Doing so can result in spurious interrupts after comparator enabling. The follow-
ing example shows how to safely enable the comparator:
di
ld cmp0
nop
nop
; wait for output to settle
clr irq0 ; clear any spurious interrupts pending
ei
Caution:
PS024705-0405
P R E L I M I N A R Y Comparator
Z8 Encore! XP
F08xA Series
Product Specification
123
Comparator Control Register Definitions
Comparator Control Register
The Comparator Control Register (CMPCTL) configures the comparator inputs and sets
the value of the internal voltage reference.
INPSEL--Signal Select for Positive Input
0 = GPIO pin used as positive comparator input
1 = temperature sensor used as positive comparator input
INNSEL--Signal Select for Negative Input
0 = internal reference disabled, GPIO pin used as negative comparator input
1 = internal reference enabled as negative comparator input
REFLVL--Internal Reference Voltage Level (note that this reference is independent of the
ADC voltage reference)
0000 = 0.0 V
0001 = 0.2 V
0010 = 0.4 V
0011 = 0.6 V
0100 = 0.8 V
0101 = 1.0 V (Default)
0110 = 1.2 V
0111 = 1.4 V
1000 = 1.6 V
1001 = 1.8 V
10101111 = Reserved
Table 76. Comparator Control Register (CMP0)
BITS
7
6
5
4
3
2
1
0
FIELD
INPSEL
INNSEL
REFLVL
Reserved
RESET
0
0
0
1
0
1
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F90H
PS024705-0405
P R E L I M I N A R Y Temperature
Sensor
Z8 Encore! XP
F08xA Series
Product Specification
124
Temperature Sensor
Overview
The on-chip Temperature Sensor allows the user the ability to measure temperature on the
die to an accuracy of roughly 7C over a range of -40 to +105C. Over a reduced range,
the accuracy is significantly better. This block is a moderately accurate temperature sensor
for low power applications where high accuracy is not required. Uncalibrated accuracy is
significantly worse, therefore the temperature sensor is not recommended for untrimmed
use.
On-chip temperature sensor
7C full-range accuracy for calibrated version
1.5C accuracy over the range of 20C to 30C
Flash recalibration capability
Operation
The on-chip temperature sensor is a PTAT (proportional to absolute temperature) topology
which has provision for zero point calibration. A pair of Flash option bytes contain the cal-
ibration data. The temperature sensor can be disabled by a bit in the
Power Control Regis-
ter 0
(page 29) to reduce power consumption.
The temperature sensor can be directly read by the ADC to determine the absolute value of
its output. The temperature sensor output is also available as an input to the comparator for
threshold type measurement determination. The accuracy of the sensor when used with the
comparator is substantially less than when measured by the ADC.
If the temperature sensor is routed to the ADC, the ADC must be configured in unity-gain
buffered mode (
See "Input Buffer Stage" on page 115.
) The value read back from the ADC
is a signed number, although it is always positive.
Maximum accuracy can be obtained by customer re-trimming the sensor using an external
reference and using a high-precision external reference in the target application.
During normal operation, the die undergoes heating that will cause a mismatch between
the ambient temperature and that measured by the sensor. For best results, the XP device
should be placed into STOP mode for sufficient time such that the die and ambient tem-
peratures converge (this time will be dependent on the thermal design of the system). The
temperature sensor measurement should then be made immediately after recovery from
STOP mode.
PS024705-0405
P R E L I M I N A R Y Temperature
Sensor
Z8 Encore! XP
F08xA Series
Product Specification
125
The following equation defines the transfer function between the temperature sensor out-
put voltage and the die temperature:
T = 100*V - 77 (where T is the temperature in C; V is the sensor output in Volts)
Assuming a compensated ADC measurement, the following equation defines the relation-
ship between the ADC reading and the die temperature:
T = (25/128)*ADC - 77 (where T is the temperature in C; ADC is the 10 bit compensated
ADC value)
Calibration
The temperature sensor undergoes calibration during the manufacturing process and is
maximally accurate only at 30C. Accuracy decreases as measured temperatures move
further from the calibration point.
Because this sensor is an on-chip sensor it is recommended that the user account for the
difference between ambient and die temperature when inferring ambient temperature con-
ditions.
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
126
Flash Memory
Overview
The products in the Z8 Encore! XP
F08xA Series features 8KB (8192) KB of non-vola-
tile Flash memory with read/write/erase capability. The Flash Memory can be pro-
grammed and erased in-circuit by either user code or through the On-Chip Debugger.
The Flash memory array is arranged in pages with 512 bytes per page. The 512-byte page
is the minimum Flash block size that can be erased. Each page is divided into 8 rows of 64
bytes.
For program/data protection, the Flash memory is also divided into sectors. In the Z8
Encore! XP
F08xA Series, these sectors are 1024 bytes in size; so the Flash memory is
divided into eight sectors.
The first 2 bytes of the Flash Program memory are used as Flash Option Bits. Refer to the
chapter "Flash Option Bits" on page 138 for more information about their operation.
Table 77 describes the Flash memory configuration for each device in the Z8 Encore! XP
F08xA Series. Figure 19 illustrates the Flash memory arrangement.
Table 77. Z8 Encore! XP
F08xA Series Flash Memory Configurations
Part Number
Flash Size
KB (Bytes)
Flash
Pages
Program Memory
Addresses
Flash Sector
Size (bytes)
Z8 Encore! XP
F08xA Series
8 (8192)
16
0000H1FFFH
1024
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
127
Figure 19.Flash Memory Arrangement
Flash Information Area
The Flash information area is separate from program memory and is mapped to the
address range
FE00H
to
FFFFH
. Not all of these addresses are user accessible. Factory trim
values for the analog peripherals are stored here. Factory calibration data for the ADC is
also stored here.
8KB Flash
Program Memory
0000
8 Sectors
1024 Bytes each
03FF
0400
1FFF
Addresses (hex)
07FF
0800
0BFF
0C00
0FFF
1000
13FF
1400
17FF
1800
1BFF
1C00
Sector 7
Sector 6
Sector 5
Sector 4
Sector 3
Sector 2
Sector 1
Sector 0
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
128
Operation
The Flash Controller programs and erases Flash memory. The Flash Controller provides
the proper Flash controls and timing for byte programming, Page Erase, and Mass Erase of
Flash memory.
The Flash Controller contains several protection mechanisms to prevent accidental pro-
gramming or erasure. These mechanism operate on the page, sector and full-memory lev-
els.
The Flow Chart in Figure 20 illustrates basic Flash Controller operation. The following
subsections provide details about the various operations (Lock, Unlock, Byte Program-
ming, Page Protect, Page Unprotect, Page Select Page Erase, and Mass Erase) listed in
Figure 20.
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
129
Figure 20.Flash Controller Operation Flow Chart
Reset
Page
73H
No
Yes
8CH
No
Yes
Program/Erase
Enabled
95H
No
Yes
Write FCTL
Lock State 0
Lock State 1
Write FCTL
Write FCTL
Byte Program
Page Erase
Write Page
Select Register
Write Page
Select Register
Page in
No
No
Unlocked
Protected Sector?
Writes to Page Select
Register in Lock State 1
result in a return to
Lock State 0
Page Select
Yes
values match?
Yes
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
130
Flash Operation Timing Using the Flash Frequency Registers
Before performing either a program or erase operation on Flash memory, the user must
first configure the Flash Frequency High and Low Byte registers. The Flash Frequency
registers allow programming and erasing of the Flash with system clock frequencies rang-
ing from 32KHz (32768Hz) through 20MHz.
The Flash Frequency High and Low Byte registers combine to form a 16-bit value,
FFREQ
, to control timing for Flash program and erase operations. The 16-bit binary Flash
Frequency value must contain the system clock frequency (in KHz). This value is calcu-
lated using the following equation:
.
Flash programming and erasure are not supported for system clock frequencies below
32KHz (32768Hz) or above 20MHz. The Flash Frequency High and Low Byte registers
must be loaded with the correct value to ensure operation of the Z8 Encore! XP
F08xA
Series devices.
Flash Code Protection Against External Access
The user code contained within the Flash memory can be protected against external access
with the On-Chip Debugger. Programming the FRP Flash Option Bit prevents reading of
the user code with the On-Chip Debugger. Refer to the chapter
"Flash Option Bits" on page 138
and the chapter
"On-Chip Debugger" on page 148
for more information.
Flash Code Protection Against Accidental Program and Erasure
The Z8 Encore! XP
F08xA Series provides several levels of protection against accidental
program and erasure of the Flash memory contents. This protection is provided by a com-
bination of the Flash Option bits, the register locking mechanism, the page select redun-
dancy and the sector level protection control of the Flash Controller.
Flash Code Protection Using the Flash Option Bits
The FHSWP and FWP Flash Option Bits combine to provide three levels of Flash Program
Memory protection as listed in Table 78. Refer to the chapter
"Flash Option Bits" on page 138
for more information.
FFREQ[15:0]
System Clock Frequency (Hz)
1000
----------------------------------------------------------------------------
=
Caution:
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
131
.
Flash Code Protection Using the Flash Controller
At Reset, the Flash Controller locks to prevent accidental program or erasure of the Flash
memory. To program or erase the Flash memory, first write the Page Select Register with
the target page. Unlock the Flash Controller by making two consecutive writes to the
Flash Control register with the values
73H
and
8CH
, sequentially. The Page Select Register
must be rewritten with the same page previously stored there. If the two Page Select writes
do not match, the controller reverts to a locked state. If the two writes match, the selected
page becomes active. See Figure 20 for details.
After unlocking a specific page, the user can enable either Page Program or Erase. Writing
the value
95H
causes a Page Erase only if the active page resides in a sector that is not pro-
tected. Any other value written to the Flash Control register locks the Flash Controller.
Mass Erase is not allowed in the user code but only in through the Debug Port.
After unlocking a specific page, the user can also write to any byte on that page. After a
byte is written, the page remains unlocked, allowing for subsequent writes to other bytes
on the same page. Further writes to the Flash Control Register cause the active page to
revert to a locked state.
Sector Based Flash Protection
The final protection mechanism is implemented on a per-sector basis. The Flash memories
of Z8 Encore!
devices are divided into maximum number of 8 sectors. A sector is 1/8 of
the total size of the Flash memory, unless this value is smaller than the page size, in which
case the sector and page sizes are equal. On the Z8 Encore! XP
F08xA Series devices,
the sector size is 1024 bytes, equal to twice the page size.
The Sector Protect Register controls the protection state of each Flash sector. This register
is shared with the Page Select Register. It is accessed by writing 73H followed by 5EH to
the Flash controller. The next write to the Flash Control Register targets the Sector Protect
Register.
The Sector Protect Register is initialized to 0 on reset, putting each sector into an unpro-
tected state. When a bit in the Sector Protect Register is written to 1, the corresponding
Table 78. Flash Code Protection Using the Flash Option Bits
FHSWP
FWP
Flash Code Protection Description
0
0
Programming and erasing disabled for all of Flash Program
Memory. In user code programming, Page Erase, and Mass Erase
are all disabled. Mass Erase is available through the On-Chip
Debugger.
0 or 1
1
Programming, Page Erase, and Mass Erase are enabled for all of
Flash Program Memory.
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
132
sector can no longer be written or erased. After a bit of the Sector Protect Register has
been set, it can not be cleared except by powering down the device.
Byte Programming
The Flash Memory is enabled for byte programming after unlocking the Flash Controller
and successfully enabling either Mass Erase or Page Erase. When the Flash Controller is
unlocked and Mass Erase is successfully enabled, all Program Memory locations are
available for byte programming. In contrast, when the Flash Controller is unlocked and
Page Erase is successfully enabled, only the locations of the selected page are available for
byte programming. An erased Flash byte contains all 1's (
FF
H
). The programming opera-
tion can only be used to change bits from 1 to 0. To change a Flash bit (or multiple bits)
from 0 to 1 requires execution of either the Page Erase or Mass Erase commands.
Byte Programming can be accomplished using the On-Chip Debugger's Write Memory
command or eZ8 CPU execution of the LDC or LDCI instructions. Refer to the eZ8 CPU
User Manual
(available for download at
www.zilog.com
)for a description of the LDC and
LDCI instructions. While the Flash Controller programs the Flash memory, the eZ8 CPU
idles but the system clock and on-chip peripherals continue to operate. To exit program-
ming mode and lock the Flash, write any value to the Flash Control register, except the
Mass Erase or Page Erase commands.
The byte at each address of the Flash memory cannot be programmed (any bits written
to 0) more than twice before an erase cycle occurs.
Page Erase
The Flash memory can be erased one page (512 bytes) at a time. Page Erasing the Flash
memory sets all bytes in that page to the value
FFH
. The Flash Page Select register identi-
fies the page to be erased. Only a page residing in an unprotected sector can be erased.
With the Flash Controller unlocked and the active page set, writing the value
95h
to the
Flash Control register initiates the Page Erase operation. While the Flash Controller exe-
cutes the Page Erase operation, the eZ8 CPU idles but the system clock and on-chip
peripherals continue to operate. The eZ8 CPU resumes operation after the Page Erase
operation completes. If the Page Erase operation is performed using the On-Chip Debug-
ger, poll the Flash Status register to determine when the Page Erase operation is complete.
When the Page Erase is complete, the Flash Controller returns to its locked state.
Mass Erase
The Flash memory can also be Mass Erased using the Flash Controller, but only by using
the On-Chip Debugger. Mass Erasing the Flash memory sets all bytes to the value
FFH
.
With the Flash Controller unlocked and the Mass Erase successfully enabled, writing the
value
63H
to the Flash Control register initiates the Mass Erase operation. While the Flash
Caution:
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
133
Controller executes the Mass Erase operation, the eZ8 CPU idles but the system clock and
on-chip peripherals continue to operate. Using the On-Chip Debugger, poll the Flash Sta-
tus register to determine when the Mass Erase operation is complete. When the Mass
Erase is complete, the Flash Controller returns to its locked state.
Flash Controller Bypass
The Flash Controller can be bypassed and the control signals for the Flash memory
brought out to the GPIO pins. Bypassing the Flash Controller allows faster Row Program-
ming algorithms by controlling the Flash programming signals directly.
Row programing is recommended for gang programming applications and large volume
customers who do not require in-circuit initial programming of the Flash memory. Mass
Erase and Page Erase operations are also supported when the Flash Controller is bypassed.
Please refer to the document entitled Third-Party Flash Programming Support for Z8
Encore!
for more information about bypassing the Flash Controller. This document is
available for download at
www.zilog.com
.
Flash Controller Behavior in Debug Mode
The following changes in behavior of the Flash Controller occur when the Flash Control-
ler is accessed using the On-Chip Debugger:
The Flash Write Protect option bit is ignored.
The Flash Sector Protect register is ignored for programming and erase operations.
Programming operations are not limited to the page selected in the Page Select
register.
Bits in the Flash Sector Protect register can be written to one or zero.
The second write of the Page Select register to unlock the Flash Controller is not
necessary.
The Page Select register can be written when the Flash Controller is unlocked.
The Mass Erase command is enabled through the Flash Control register.
For security reasons, flash controller allows only a single page to be opened for write/
erase. When writing multiple flash pages, the flash controller must go through the un-
lock sequence again to select another page.
Caution:
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
134
Flash Control Register Definitions
Flash Control Register
The Flash Controller must be unlocked using the Flash Control register before program-
ming or erasing the Flash memory. Writing the sequence
73H
8CH
, sequentially, to the
Flash Control register unlocks the Flash Controller. When the Flash Controller is
unlocked, the Flash memory can be enabled for Mass Erase or Page Erase by writing the
appropriate enable command to the FCTL. Page Erase applies only to the active page
selected in Flash Page Select register. Mass Erase is enabled only through the On-Chip
Debugger. Writing an invalid value or an invalid sequence returns the Flash Controller to
its locked state. The Write-only Flash Control Register shares its Register File address
with the read-only Flash Status Register
.
FCMD--Flash Command
73H = First unlock command.
8CH = Second unlock command.
95H = Page Erase command (must be third command in sequence to initiate Page Erase).
63H = Mass Erase command (must be third command in sequence to initiate Mass Erase).
5EH = Enable Flash Sector Protect Register Access
Flash Status Register
The Flash Status register indicates the current state of the Flash Controller. This register
can be read at any time. The read-only Flash Status Register shares its Register File
address with the Write-only Flash Control Register.
Table 79. Flash Control Register (FCTL)
BITS
7
6
5
4
3
2
1
0
FIELD
FCMD
RESET
0
0
0
0
0
0
0
0
R/W
W
W
W
W
W
W
W
W
ADDR
FF8H
Table 80. Flash Status Register (FSTAT)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
FSTAT
RESET
0
0
0
0
0
0
0
0
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
135
Reserved--Must be 0.
FSTAT--Flash Controller Status
000000 = Flash Controller locked.
000001 = First unlock command received (73H written).
000010 = Second unlock command received (8CH written).
000011 = Flash Controller unlocked.
000100 = Sector protect register selected.
001xxx = Program operation in progress.
010xxx = Page erase operation in progress.
100xxx = Mass erase operation in progress
Flash Page Select Register
The Flash Page Select register shares address space with the Flash Sector Protect Register.
Unless the Flash controller is unlocked and written with 5EH, writes to this address target
the Flash Page Select Register.
The register is used to select one of the 8 available Flash memory pages to be programmed
or erased. Each Flash Page contains 512 bytes of Flash memory. During a Page Erase
operation, all Flash memory having addresses with the most significant 7-bits given by
FPS[6:0] are chosen for program/erase operation.
INFO_EN--Information Area Enable
0 = Information Area us not selected
1 = Information Area is selected. The Information Area is mapped into the Program Mem-
ory address space at addresses FE00H through FFFFH.
PAGE--Page Select
This 7-bit field identifies the Flash memory page for Page Erase and page unlocking.
R/W
R
R
R
R
R
R
R
R
ADDR
FF8H
Table 81. Flash Page Select Register (FPS)
BITS
7
6
5
4
3
2
1
0
FIELD
INFO_EN
PAGE
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FF9H
Table 80. Flash Status Register (FSTAT)
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
136
Program Memory Address[15:9] = PAGE[6:0]. For the Z8F04xx and Z8F02xx devices,
the upper 4 bits must always be 0. For the Z8F01xx devices, the upper 5 bits must always
to 0.
Flash Sector Protect Register
The Flash Sector Protect register is shared with the Flash Page Select Register. When the
Flash Control Register
is written with 73H followed by 5EH, the next write to this
address targets the Flash Sector Protect Register. In all other cases, it targets the Flash
Page Select Register.
This register selects one of the 8 available Flash memory sectors to be protected. The reset
state of each Sector Protect bit is an unprotected state. After a sector is protected by setting
its corresponding register bit, it cannot be unprotected (the register bit cannot be cleared)
without powering down the device.
SPROT7-SPROT0--Sector Protection
Each bit corresponds to a 1024 byte Flash sector. For the Z8 Encore! XP
F08xA Series
devices all bits are used.
Flash Frequency High and Low Byte Registers
The Flash Frequency High and Low Byte registers combine to form a 16-bit value,
FFREQ, to control timing for Flash program and erase operations. The 16-bit binary Flash
Frequency value must contain the system clock frequency (in KHz) and is calculated using
the following equation:.
Flash programming and erasure is not supported for system clock frequencies below
20KHz or above 20MHz. The Flash Frequency High and Low Byte registers must be
loaded with the correct value to ensure proper operation of the device.
Table 82. Flash Sector Protect Register (FPROT)
BITS
7
6
5
4
3
2
1
0
FIELD
SPROT7
SPROT6
SPROT5
SPROT4
SPROT3
SPROT2
SPROT1
SPROT0
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FF9H
FFREQ[15:0]
FFREQH[7:0],FFREQL[7:0]
{
}
System Clock Frequency
1000
---------------------------------------------------------------
=
=
Caution:
PS024705-0405
P R E L I M I N A R Y Flash
Memory
Z8 Encore! XP
F08xA Series
Product Specification
137
FFREQH--Flash Frequency High Byte
High byte of the 16-bit Flash Frequency value.
FFREQL--Flash Frequency Low Byte
Low byte of the 16-bit Flash Frequency value.
Table 83. Flash Frequency High Byte Register (FFREQH)
BITS
7
6
5
4
3
2
1
0
FIELD
FFREQH
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FFAH
Table 84. Flash Frequency Low Byte Register (FFREQL)
BITS
7
6
5
4
3
2
1
0
FIELD
FFREQL
RESET
0
R/W
R/W
ADDR
FFBH
PS024705-0405
P R E L I M I N A R Y
Flash Option Bits
Z8 Encore! XP
F08xA Series
Product Specification
138
Flash Option Bits
Overview
Programmable Flash Option Bits allow user configuration of certain aspects of Z8 Encore!
XP
F08xA Series operation. The feature configuration data is stored in the Flash Pro-
gram Memory and read during Reset. The features available for control through the Flash
Option Bits are:
Watch-Dog Timer time-out response selectioninterrupt or system reset
Watch-Dog Timer enabled at Reset
The ability to prevent unwanted read access to user code in Program Memory
The ability to prevent accidental programming and erasure of all or a portion of the user
code in Program Memory
Voltage Brown-Out configuration-always enabled or disabled during STOP mode to re-
duce STOP mode power consumption
Voltage Brown-Out response selectioninterrupt or System Reset
Oscillator mode selection-for high, medium, and low power crystal oscillators, or external
RC oscillator
Factory trimming information for the Internal Precision Oscillator and Temperature Sen-
sor
Factory calibration values for ADC compensation
Operation
Option Bit Configuration By Reset
Each time the Flash Option Bits are programmed or erased, the device must be Reset for
the change to take effect. During any reset operation (System Reset, system reset, or STOP
Mode Recovery), the Flash Option Bits are automatically read from the Flash Program
Memory and written to Option Configuration registers. The Option Configuration regis-
ters control operation of the devices within the Z8 Encore! XP
F08xA Series. Option Bit
control is established before the device exits Reset and the eZ8 CPU begins code execu-
tion. The Option Configuration registers are not part of the Register File and are not acces-
sible for read or write access.
PS024705-0405
P R E L I M I N A R Y
Flash Option Bits
Z8 Encore! XP
F08xA Series
Product Specification
139
Option Bit Types
User Option Bits
The user option bits are contained in the first two bytes of program memory. User access
to these bits has been provided because these locations contain application-specific device
configurations. The information contained here is lost when page 0 of the program mem-
ory is erased.
Trim Option Bits
The trim option bits are contained in the information page of the Flash memory. These bits
are factory programmed values required to optimize the operation of onboard analog cir-
cuitry and cannot be permanently altered by the user. Program memory may be erased
without endangering these values. It is possible to alter working values of these bits by
accessing the Trim Bit Address and Data Registers, but these working values are lost after
a power loss.
There are 32 bytes of trim data. To modify one of these values the user code must first
write a value between
00H
and
1FH
into the Trim Bit Address Register. The next write to
the Trim Bit Data register changes the working value of the target trim data byte.
Reading the trim data requires the user code to write a value between
00H
and
1FH
into the
Trim Bit Address Register. The next read from the Trim Bit Data register returns the work-
ing value of the target trim data byte.
The trim address range is from information address 20-3F only. The remainder of the
information page is not accessible through the trim bit address and data registers.
Calibration Option Bits
The calibration option bits are also contained in the information page. These bits are fac-
tory programmed values intended for use in software correcting the device's analog per-
formance. To read these values, the user code must employ the LDC instruction to access
the information of the address space, as defined in "Flash Information Area" on page 13.
The following code example shows how to read the calibration data from the flash infor-
mation area.
; get value at info address 60 (FE60h)
ldx FPS, #%80 ; enable access to flash info page
ld R0, #%FE
ld R1, #%60
ldc R2, @RR0 ; R2 now contains the calibration value
Note:
PS024705-0405
P R E L I M I N A R Y
Flash Option Bits
Z8 Encore! XP
F08xA Series
Product Specification
140
Flash Option Bit Control Register Definitions
Trim Bit Address Register
This register contains the target address for an access to the trim option bits.
Trim Bit Data Register
This register contains the read or write data for access to the trim option bits.
Flash Option Bit Address Space
The first two bytes of Flash Program Memory at addresses
0000H
and
0001H
are reserved
for the user-programmable Flash Option Bits.
Table 85. Trim Bit Address Register (TRMADR)
BITS
7
6
5
4
3
2
1
0
FIELD
TRMADR - Trim Bit Address (00H to 1FH)
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FF6H
Table 86. Trim Bit Data Register (TRMDR)
BITS
7
6
5
4
3
2
1
0
FIELD
TRMDR - Trim Bit Data
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
FF7H
PS024705-0405
P R E L I M I N A R Y
Flash Option Bits
Z8 Encore! XP
F08xA Series
Product Specification
141
Flash Program Memory Address 0000H
WDT_RES--Watch-Dog Timer Reset
0 = Watch-Dog Timer time-out generates an interrupt request. Interrupts must be globally
enabled for the eZ8 CPU to acknowledge the interrupt request.
1 = Watch-Dog Timer time-out causes a system reset. This setting is the default for unpro-
grammed (erased) Flash.
WDT_AO--Watch-Dog Timer Always On
0 = Watch-Dog Timer is automatically enabled upon application of system power. Watch-
Dog Timer can not be disabled.
1 = Watch-Dog Timer is enabled upon execution of the WDT instruction. Once enabled,
the Watch-Dog Timer can only be disabled by a Reset or STOP Mode Recovery. This set-
ting is the default for unprogrammed (erased) Flash.
OSC_SEL[1:0]--Oscillator Mode Selection
00 = On-chip oscillator configured for use with external RC networks (<4MHz).
01 = Minimum power for use with very low frequency crystals (32KHz to 1.0MHz).
10 = Medium power for use with medium frequency crystals or ceramic resonators
(0.5MHz to 5.0MHz).
11 = Maximum power for use with high frequency crystals (5.0MHz to 20.0MHz). This
setting is the default for unprogrammed (erased) Flash.
VBO_AO--Voltage Brown-Out Protection Always On
0 = Voltage Brown-Out Protection is disabled in STOP mode to reduce total power con-
sumption.
1 = Voltage Brown-Out Protection is always enabled including during STOP mode. This
setting is the default for unprogrammed (erased) Flash.
FRP--Flash Read Protect
0 = User program code is inaccessible. Limited control features are available through the
On-Chip Debugger.
1 = User program code is accessible. All On-Chip Debugger commands are enabled. This
setting is the default for unprogrammed (erased) Flash.
Reserved--Must be 1.
Table 87. Flash Option Bits at Program Memory Address 0000H
BITS
7
6
5
4
3
2
1
0
FIELD
WDT_RES WDT_AO
OSC_SEL[1:0]
VBO_AO
FRP
Reserved
FWP
RESET
U
U
U
U
U
U
U
U
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
Program Memory 0000H
Note: U = Unchanged by Reset. R/W = Read/Write.
PS024705-0405
P R E L I M I N A R Y
Flash Option Bits
Z8 Encore! XP
F08xA Series
Product Specification
142
FWP--Flash Write Protect
This Option Bit provides Flash Program Memory protection:
0 = Programming and erasure disabled for all of Flash Program Memory. Programming,
Page Erase, and Mass Erase through User Code is disabled. Mass Erase is available using
the On-Chip Debugger.
1 = Programming, Page Erase, and Mass Erase are enabled for all of Flash Program Mem-
ory.
Flash Program Memory Address 0001H
Reserved--Must be 1.
XTLDIS--State of Crystal Oscillator at Reset
This bit only enables the crystal oscillator, its selection as system clock must be done man-
ually.
0 = Crystal oscillator is enabled during reset, resulting in longer reset timing
1 = Crystal oscillator is disabled during reset, resulting in shorter reset timing
Trim Bit Address Space
Trim Bit Address 0000H
Table 88. Flash Options Bits at Program Memory Address 0001H
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
XTLDIS
Reserved
RESET
U
U
U
U
U
U
U
U
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
Program Memory 0001H
Note: U = Unchanged by Reset. R/W = Read/Write.
Table 89. Trim Options Bits at Address 0000H (TTEMP0)
BITS
7
6
5
4
3
2
1
0
FIELD
TS_FINE
Reserved
TS_ULTRAFINE
RESET
U
U
U
U
U
U
U
U
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
Information Page Memory 0020H
Note: U = Unchanged by Reset. R/W = Read/Write.
Note:
PS024705-0405
P R E L I M I N A R Y
Flash Option Bits
Z8 Encore! XP
F08xA Series
Product Specification
143
TS_FINE--Temperature Sensor Fine Control Trim Bits
Contains fine control offset trimming bits for Temperature Sensor.
Reserved--Must be 1.
TS_ULTRAFINE--Temperature Sensor Ultra Fine Control Trim Bits
Contains ultra fine control offset trimming bits for Temperature Sensor.
Trim Bit Address 0001H
Reserved--Must be 1.
TS_COARSE--Temperature Sensor Coarse Control Trim Bits
Contains coarse control offset trimming bits for Temperature Sensor.
Trim Bit Address 0002H
IPO_TRIM--Internal Precision Oscillator Trim Byte
Contains trimming bits for Internal Precision Oscillator.
Table 90. Trim Option Bits at 0001H (TTEMP1)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
TS_COARSE
RESET
U
U
U
U
U
U
U
U
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
Information Page Memory 0021H
Note: U = Unchanged by Reset. R/W = Read/Write.
Table 91. Trim Option Bits at 0002H (TIPO)
BITS
7
6
5
4
3
2
1
0
FIELD
IPO_TRIM
RESET
U
R/W
R/W
ADDR
Information Page Memory 0022H
Note: U = Unchanged by Reset. R/W = Read/Write.
PS024705-0405
P R E L I M I N A R Y
Flash Option Bits
Z8 Encore! XP
F08xA Series
Product Specification
144
Trim Bit Address 0003H
Reserved--Must be 1.
LVD_TRIM--Low Voltage Detect Trim
This trimming affects the low voltage detection threshold. Each LSB represents a
50mV change in the threshold level. Alternatively, the low voltage threshold may
be computed from the options bit value by the following equation:
LVD_LVL = 3.2V - LVD_TRIM * 0.05V
Table 92. Trim Option Bits at Address 0003H (TLVD)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
LVD_TRIM
RESET
U
U
U
U
U
U
U
U
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
Information Page Memory 0023H
Note: U = Unchanged by Reset. R/W = Read/Write.
LVD Threshold (V)
LVD_TRIM
Minimum
Typical
Maximum Description
00000
TBD
3.20
TBD
Maximum LVD threshold
00001
TBD
3.15
TBD
00010
TBD
3.10
TBD
00011
TBD
3.05
TBD
00100
to
01010
TBD
3.00
to
2.79
TBD
Default on Reset and to be programmed into Flash
before customer delivery to ensure 2.7V operation.
01010
to
11111
TBD
2.70
to
1.65
TBD
Minimum LVD threshold
PS024705-0405
P R E L I M I N A R Y
Flash Option Bits
Z8 Encore! XP
F08xA Series
Product Specification
145
Trim Bit Address 0004H
Reserved--Must be 1.
BG_TRIM--Band Gap Trim Values
Contains factory trimmed values for the band gap output voltage adjustment.
ZiLOG Calibration Bits
ADC Calibration Bits
ADC_CAL--Analog to Digital Converter Calibration Values
Contains factory calibrated values for ADC gain and offset compensation. Each of the ten
supported modes has one byte of offset calibration and two bytes of gain calibration.
These values are read by user software to compensate ADC measurements as detailed in
"Software Compensation Procedure" on page 114. The location of each calibration byte is
provided in Table 95.
Table 93. Trim Option Bits at 0004H (TBG)
BITS
7
6
5
4
3
2
1
0
FIELD
Reserved
BG_TRIM
RESET
U
U
U
U
U
U
U
U
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
Information Page Memory 0024H
Note: U = Unchanged by Reset. R/W = Read/Write.
Table 94. ADC Calibration Bits at 0060H-007DH
BITS
7
6
5
4
3
2
1
0
FIELD
ADC_CAL
RESET
U
U
U
U
U
U
U
U
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
Information Page Memory 0060H007DH
Note: U = Unchanged by Reset. R/W = Read/Write.
PS024705-0405
P R E L I M I N A R Y
Flash Option Bits
Z8 Encore! XP
F08xA Series
Product Specification
146
Table 95. ADC Calibration Data Location
Info Page
Address
Memory
Address
Compensation
Usage
ADC Mode
Reference Type
60
FE60
Offset
Single-Ended Unbuffered
Internal 2.0V
08
FE08
Gain High Byte
Single-Ended Unbuffered
Internal 2.0V
09
FE09
Gain Low Byte
Single-Ended Unbuffered
Internal 2.0V
63
FE63
Offset
Single-Ended Unbuffered
Internal 1.0V
0A
FE0A
Gain High Byte
Single-Ended Unbuffered
Internal 1.0V
0B
FE0B
Gain Low Byte
Single-Ended Unbuffered
Internal 1.0V
66
FE66
Offset
Single-Ended Unbuffered
External 2.0V
0C
FE0C
Gain High Byte
Single-Ended Unbuffered
External 2.0V
0D
FE0D
Gain Low Byte
Single-Ended Unbuffered
External 2.0V
69
FE69
Offset
Single Ended 1x Buffered
Internal 2.0V
0E
FE0E
Gain High Byte
Single Ended 1x Buffered
Internal 2.0V
0F
FE0F
Gain Low Byte
Single Ended 1x Buffered
Internal 2.0V
6C
FE6C
Offset
Single Ended 1x Buffered
External 2.0V
10
FE10
Gain High Byte
Single Ended 1x Buffered
External 2.0V
11
FE11
Gain Low Byte
Single Ended 1x Buffered
External 2.0V
6F
FE6F
Offset
Differential Unbuffered
Internal 2.0V
12
FE12
Gain High Byte
Differential Unbuffered
Internal 2.0V
13
FE13
Gain Low Byte
Differential Unbuffered
Internal 2.0V
72
FE72
Offset
Differential Unbuffered
Internal 1.0V
14
FE14
Gain High Byte
Differential Unbuffered
Internal 1.0V
15
FE15
Gain Low Byte
Differential Unbuffered
Internal 1.0V
75
FE75
Offset
Differential Unbuffered
External 2.0V
16
FE16
Gain High Byte
Differential Unbuffered
External 2.0V
17
FE17
Gain Low Byte
Differential Unbuffered
External 2.0V
78
FE78
Offset
Differential 1x Buffered
Internal 2.0V
18
FE18
Gain High Byte
Differential 1x Buffered
Internal 2.0V
19
FE19
Gain Low Byte
Differential 1x Buffered
Internal 2.0V
7B
FE7B
Offset
Differential 1x Buffered
External 2.0V
PS024705-0405
P R E L I M I N A R Y
Flash Option Bits
Z8 Encore! XP
F08xA Series
Product Specification
147
Watchdog Timer Calibration Bits
WDTCALH--Watchdog Timer Calibration High Byte
The WDTCALH and WDTCALL bytes, when loaded into the watchdog timer reload reg-
isters result in a one second timeout at room temperature and 3.3V supply voltage. To use
the Watch-Dog Timer calibration, user code must load WDTU with 0x00, WDTH with
WDTCALH and WDTL with WDTCALL.
WDTCALL--Watchdog Timer Calibration Low Byte
The WDTCALH and WDTCALL bytes, when loaded into the watchdog timer reload reg-
isters result in a one second timeout at room temperature and 3.3V supply voltage. To use
the watchdog timer calibration, user code must load WDTU with 0x00, WDTH with
WDTCALH and WDTL with WDTCALL.
1A
FE1A
Gain High Byte
Differential 1x Buffered
External 2.0V
1B
FE1B
Gain Low Byte
Differential 1x Buffered
External 2.0V
Table 96. Watchdog Calibration High Byte at 007EH (WDTCALH)
BITS
7
6
5
4
3
2
1
0
FIELD
WDTCALH
RESET
U
U
U
U
U
U
U
U
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
Information Page Memory 007EH
Note: U = Unchanged by Reset. R/W = Read/Write.
Table 97. Watchdog Calibration Low Byte at 007FH (WDTCALL)
BITS
7
6
5
4
3
2
1
0
FIELD
WDTCALL
RESET
U
U
U
U
U
U
U
U
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
Information Page Memory 007FH
Note: U = Unchanged by Reset. R/W = Read/Write.
Table 95. ADC Calibration Data Location (Continued)
Info Page
Address
Memory
Address
Compensation
Usage
ADC Mode
Reference Type
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
148
On-Chip Debugger
Overview
The Z8 Encore! XP
TM
devices contain an integrated On-Chip Debugger (OCD) that pro-
vides advanced debugging features including:
Reading and writing of the Register File
Reading and writing of Program and Data Memory
Setting of Breakpoints and Watchpoints
Executing eZ8 CPU instructions
Architecture
The On-Chip Debugger consists of four primary functional blocks: transmitter, receiver,
auto-baud detector/generator, and debug controller. Figure 21 illustrates the architecture of
the On-Chip Debugger
Figure 21.On-Chip Debugger Block Diagram
Auto-Baud
System Clock
Transmitter
Receiver
DBG Pin
Debug Controller
eZ
8 CPU Control
Detector/Generator
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
149
Operation
OCD Interface
The On-Chip Debugger uses the DBG pin for communication with an external host. This
one-pin interface is a bi-directional open-drain interface that transmits and receives data.
Data transmission is half-duplex, in that transmit and receive cannot occur simultaneously.
The serial data on the DBG pin is sent using the standard asynchronous data format
defined in RS-232. This pin creates an interface from the Z8 Encore! XP
F08xA Series
products to the serial port of a host PC using minimal external hardware.Two different
methods for connecting the DBG pin to an RS-232 interface are depicted in Figures 22
and 23 . The recommended method is the buffered implementation depicted in Figure 23 .
The DBG pin must always be connected to V
DD
through an external pull-up resistor.
For operation of the On-Chip Debugger, all power pins (V
DD
and AV
DD
)
must be supplied with power, and all ground pins (V
SS
and AV
SS
) must be
properly grounded.
The
DBG
pin is open-drain and must always be connected to V
DD
through
an external pull-up resistor to insure proper operation.
Figure 22.Interfacing the On-Chip Debugger's DBG Pin with an RS-232 Interface (1)
Caution:
RS-232 TX
RS-232 RX
RS-232
Transceiver
VDD
DBG Pin
10KOhm
Schottky
Diode
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
150
Figure 23.Interfacing the On-Chip Debugger's DBG Pin with an RS-232 Interface (2)
DEBUG Mode
The operating characteristics of the devices in DEBUG mode are:
The eZ8 CPU fetch unit stops, idling the eZ8 CPU, unless directed by the OCD to execute
specific instructions
The system clock operates unless in STOP mode
All enabled on-chip peripherals operate unless in STOP mode
Automatically exits HALT mode
Constantly refreshes the Watch-Dog Timer, if enabled
Entering DEBUG Mode
The device enters DEBUG mode after the eZ8 CPU executes a BRK (Breakpoint) instruc-
tion.
If the DBG pin is held Low during the most recent clock cycle of system reset, the part
enters DEBUG mode upon exiting system reset.
Exiting DEBUG Mode
The device exits DEBUG mode following any of these operations:
Clearing the DBGMODE bit in the OCD Control Register to 0.
Power-on reset
Voltage Brown-Out reset
Watch-Dog Timer reset
RS-232 TX
RS-232 RX
RS-232
Transceiver
VDD
DBG Pin
10KOhm
Open-Drain
Buffer
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
151
Asserting the RESET pin Low to initiate a Reset.
Driving the DBG pin Low while the device is in STOP mode initiates a System Reset.
OCD Data Format
The OCD interface uses the asynchronous data format defined for RS-232. Each character
is transmitted as 1 Start bit, 8 data bits (least-significant bit first), and 1.5 Stop bits
(Figure 24)
Figure 24.OCD Data Format
OCD Auto-Baud Detector/Generator
To run over a range of baud rates (data bits per second) with various system clock frequen-
cies, the On-Chip Debugger contains an Auto-Baud Detector/Generator. After a reset, the
OCD is idle until it receives data. The OCD requires that the first character sent from the
host is the character
80H
. The character
80H
has eight continuous bits Low (one Start bit
plus 7 data bits), framed between High bits. The Auto-Baud Detector measures this period
and sets the OCD Baud Rate Generator accordingly.
The Auto-Baud Detector/Generator is clocked by the system clock. The minimum baud
rate is the system clock frequency divided by 512. For optimal operation with asynchro-
nous datastreams, the maximum recommended baud rate is the system clock frequency
divided by 8. The maximum possible baud rate for asynchronous datastreams is the sys-
tem clock frequency divided by 4, but this theoretical maximum is possible only for low
noise designs with clean signals. Table 98 lists minimum and recommended maximum
baud rates for sample crystal frequencies.
Table 98. OCD Baud-Rate Limits
System Clock Frequency
(MHz)
Recommended
Maximum Baud
Rate (Kbps)
Recommended
Standard PC Baud
Rate (bps)
Minimum Baud
Rate (Kbps)
20.0
2500.0
1,843,200
39
1.0
125.0
115,200
1.95
0.032768 (32KHz)
4.096
2400
0.064
START
D0
D1
D2
D3
D4
D5
D6
D7
STOP
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
152
If the OCD receives a Serial Break (nine or more continuous bits Low) the Auto-Baud
Detector/Generator resets. Reconfigure the Auto-Baud Detector/Generator by sending
80H
.
OCD Serial Errors
The On-Chip Debugger can detect any of the following error conditions on the DBG pin:
Serial Break (a minimum of nine continuous bits Low)
Framing Error (received
Stop
bit is Low)
Transmit Collision (OCD and host simultaneous transmission detected by the OCD)
When the OCD detects one of these errors, it aborts any command currently in progress,
transmits a four character long Serial Break back to the host, and resets the Auto-Baud
Detector/Generator. A Framing Error or Transmit Collision may be caused by the host
sending a Serial Break to the OCD. Because of the open-drain nature of the interface,
returning a Serial Break break back to the host only extends the length of the Serial Break
if the host releases the Serial Break early.
The host transmits a Serial Break on the
DBG
pin when first connecting to the Z8 Encore!
XP
F08xA Series devices or when recovering from an error. A Serial Break from the host
resets the Auto-Baud Generator/Detector but does not reset the OCD Control register. A
Serial Break leaves the device in DEBUG mode if that is the current mode. The OCD is
held in Reset until the end of the Serial Break when the DBG pin returns High. Because of
the open-drain nature of the DBG pin, the host can send a Serial Break to the OCD even if
the OCD is transmitting a character.
Breakpoints
Execution Breakpoints are generated using the BRK instruction (opcode
00H
). When the
eZ8 CPU decodes a BRK instruction, it signals the On-Chip Debugger. If Breakpoints are
enabled, the OCD enters DEBUG mode and idles the eZ8 CPU. If Breakpoints are not
enabled, the OCD ignores the BRK signal and the
BRK
instruction operates as an NOP
instruction.
Breakpoints in Flash Memory
The
BRK
instruction is opcode
00H
, which corresponds to the fully programmed state of a
byte in Flash memory. To implement a Breakpoint, write
00H
to the required break
address, overwriting the current instruction. To remove a Breakpoint, the corresponding
page of Flash memory must be erased and reprogrammed with the original data.
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
153
Runtime Counter
The On-Chip Debugger contains a 16-bit Runtime Counter. It counts system clock cycles
between Breakpoints. The counter starts counting when the On-Chip Debugger leaves
DEBUG mode and stops counting when it enters DEBUG mode again or when it reaches
the maximum count of
FFFFH
.
On-Chip Debugger Commands
The host communicates to the On-Chip Debugger by sending OCD commands using the
DBG interface. During normal operation, only a subset of the OCD commands are avail-
able. In DEBUG mode, all OCD commands become available unless the user code and
control registers are protected by programming the Flash Read Protect Option bit (
FRP
).
The Flash Read Protect Option bit prevents the code in memory from being read out of the
Z8 Encore! XP
F08xA Series products. When this option is enabled, several of the OCD
commands are disabled. Table 99 on page 158 is a summary of the On-Chip Debugger
commands. Each OCD command is described in further detail in the bulleted list follow-
ing this table. Table 99 also indicates those commands that operate when the device is not
in DEBUG mode (normal operation) and those commands that are disabled by program-
ming the Flash Read Protect Option bit.
Debug Command
Command
Byte
Enabled when NOT
in DEBUG mode?
Disabled by
Flash Read Protect Option Bit
Read OCD Revision
00H
Yes
Reserved
01H
Read OCD Status Register
02H
Yes
Read Runtime Counter
03H
Write OCD Control Register
04H
Yes
Cannot clear DBGMODE bit
Read OCD Control Register
05H
Yes
Write Program Counter
06H
Disabled
Read Program Counter
07H
Disabled
Write Register
08H
Only writes of the Flash Memory Control
registers are allowed. Additionally, only
the Mass Erase command is allowed to
be written to the Flash Control register.
Read Register
09H
Disabled
Write Program Memory
0AH
Disabled
Read Program Memory
0BH
Disabled
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
154
In the following bulleted list of OCD Commands, data and commands sent from the host
to the On-Chip Debugger are identified by '
DBG
Command/Data
'. Data sent from the
On-Chip Debugger back to the host is identified by '
DBG
Data
'
Read OCD Revision (00H)--The Read OCD Revision command determines the ver-
sion of the On-Chip Debugger. If OCD commands are added, removed, or changed, this
revision number changes.
DBG
00H
DBG
OCDRev[15:8] (Major revision number)
DBG
OCDRev[7:0] (Minor revision number)
Read OCD Status Register (02H)--The Read OCD Status Register command reads the
OCDSTAT register.
DBG
02H
DBG
OCDSTAT[7:0]
Read Runtime Counter (03H)--The Runtime Counter counts system clock cycles in
between Breakpoints. The 16-bit Runtime Counter counts up from
0000H
and stops at the
maximum count of
FFFFH
. The Runtime Counter is overwritten during the Write Memo-
ry, Read Memory, Write Register, Read Register, Read Memory CRC, Step Instruction,
Stuff Instruction, and Execute Instruction commands.
DBG
03H
DBG
RuntimeCounter[15:8]
DBG
RuntimeCounter[7:0]
Write OCD Control Register (04H)--The Write OCD Control Register command
writes the data that follows to the OCDCTL register. When the Flash Read Protect Option
Bit is enabled, the DBGMODE bit (
OCDCTL
[7]) can only be set to 1, it cannot be cleared
Write Data Memory
0CH
Yes
Read Data Memory
0DH
Read Program Memory CRC
0EH
Reserved
0FH
Step Instruction
10H
Disabled
Stuff Instruction
11H
Disabled
Execute Instruction
12H
Disabled
Reserved
13HFFH
Debug Command
Command
Byte
Enabled when NOT
in DEBUG mode?
Disabled by
Flash Read Protect Option Bit
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
155
to 0 and the only method of returning the device to normal operating mode is to reset the
device.
DBG
04H
DBG
OCDCTL[7:0]
Read OCD Control Register (05H)--The Read OCD Control Register command reads
the value of the OCDCTL register.
DBG
05H
DBG
OCDCTL[7:0]
Write Program Counter (06H)--The Write Program Counter command writes the data
that follows to the eZ8 CPU's Program Counter (PC). If the device is not in DEBUG mode
or if the Flash Read Protect Option bit is enabled, the Program Counter (PC) values are
discarded.
DBG
06H
DBG
ProgramCounter[15:8]
DBG
ProgramCounter[7:0]
Read Program Counter (07H)--The Read Program Counter command reads the value
in the eZ8 CPU's Program Counter (PC). If the device is not in DEBUG mode or if the
Flash Read Protect Option bit is enabled, this command returns
FFFFH
.
DBG
07H
DBG
ProgramCounter[15:8]
DBG
ProgramCounter[7:0]
Write Register (08H)--The Write Register command writes data to the Register File.
Data can be written 1256 bytes at a time (256 bytes can be written by setting size to 0). If
the device is not in DEBUG mode, the address and data values are discarded. If the Flash
Read Protect Option
bit is enabled, only writes to the Flash Control Registers are allowed
and all other register write data values are discarded.
DBG
08H
DBG
{4'h0,Register Address[11:8]}
DBG
Register Address[7:0]
DBG
Size[7:0]
DBG
1-256 data bytes
Read Register (09H)--The Read Register command reads data from the Register File.
Data can be read 1256 bytes at a time (256 bytes can be read by setting size to 0). If the
device is not in DEBUG mode or if the Flash Read Protect Option bit is enabled, this com-
mand returns
FFH
for all the data values.
DBG
09H
DBG
{4'h0,Register Address[11:8]
DBG
Register Address[7:0]
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
156
DBG
Size[7:0]
DBG
1-256 data bytes
Write Program Memory (0AH)--The Write Program Memory command writes data
to Program Memory. This command is equivalent to the LDC and LDCI instructions. Data
can be written 165536 bytes at a time (65536 bytes can be written by setting size to 0).
The on-chip Flash Controller must be written to and unlocked for the programming oper-
ation to occur. If the Flash Controller is not unlocked, the data is discarded. If the device
is not in DEBUG mode or if the Flash Read Protect Option bit is enabled, the data is dis-
carded.
DBG
0AH
DBG
Program Memory Address[15:8]
DBG
Program Memory Address[7:0]
DBG
Size[15:8]
DBG
Size[7:0]
DBG
1-65536 data bytes
Read Program Memory (0BH)--The Read Program Memory command reads data
from Program Memory. This command is equivalent to the LDC and LDCI instructions.
Data can be read 165536 bytes at a time (65536 bytes can be read by setting size to 0). If
the device is not in DEBUG mode or if the Flash Read Protect Option Bit is enabled, this
command returns
FFH
for the data.
DBG
0BH
DBG
Program Memory Address[15:8]
DBG
Program Memory Address[7:0]
DBG
Size[15:8]
DBG
Size[7:0]
DBG
1-65536 data bytes
Write Data Memory (0CH)--The Write Data Memory command writes data to Data
Memory. This command is equivalent to the LDE and LDEI instructions. Data can be writ-
ten 165536 bytes at a time (65536 bytes can be written by setting size to 0). If the device
is not in DEBUG mode or if the Flash Read Protect Option Bit is enabled, the data is dis-
carded.
DBG
0CH
DBG
Data Memory Address[15:8]
DBG
Data Memory Address[7:0]
DBG
Size[15:8]
DBG
Size[7:0]
DBG
1-65536 data bytes
Read Data Memory (0DH)--The Read Data Memory command reads from Data Mem-
ory. This command is equivalent to the LDE and LDEI instructions. Data can be read 1 to
65536 bytes at a time (65536 bytes can be read by setting size to 0). If the device is not in
DEBUG mode, this command returns
FFH
for the data.
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
157
DBG
0DH
DBG
Data Memory Address[15:8]
DBG
Data Memory Address[7:0]
DBG
Size[15:8]
DBG
Size[7:0]
DBG
1-65536 data bytes
Read Program Memory CRC (0EH)--The Read Program Memory CRC command
computes and returns the Cyclic Redundancy Check (CRC) of Program Memory using the
16-bit CRC-CCITT polynomial. If the device is not in DEBUG mode, this command re-
turns
FFFFH
for the CRC value. Unlike most other OCD Read commands, there is a delay
from issuing of the command until the OCD returns the data. The OCD reads the Program
Memory, calculates the CRC value, and returns the result. The delay is a function of the
Program Memory size and is approximately equal to the system clock period multiplied
by the number of bytes in the Program Memory.
DBG
0EH
DBG
CRC[15:8]
DBG
CRC[7:0]
Step Instruction (10H)--The Step Instruction command steps one assembly instruction
at the current Program Counter (PC) location. If the device is not in DEBUG mode or the
Flash Read Protect Option bit is enabled, the OCD ignores this command.
DBG
10H
Stuff Instruction (11H)--The Stuff Instruction command steps one assembly instruction
and allows specification of the first byte of the instruction. The remaining 0-4 bytes of the
instruction are read from Program Memory. This command is useful for stepping over in-
structions where the first byte of the instruction has been overwritten by a Breakpoint. If
the device is not in DEBUG mode or the Flash Read Protect Option bit is enabled, the
OCD ignores this command.
DBG
11H
DBG
opcode[7:0]
Execute Instruction (12H)--The Execute Instruction command allows sending an en-
tire instruction to be executed to the eZ8 CPU. This command can also step over Break-
points. The number of bytes to send for the instruction depends on the opcode. If the device
is not in DEBUG mode or the Flash Read Protect Option bit is enabled, this command
reads and discards one byte.
DBG
12H
DBG
1-5 byte opcode
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
158
On-Chip Debugger Control Register Definitions
OCD Control Register
The OCD Control register controls the state of the On-Chip Debugger. This register is
used to enter or exit DEBUG mode and to enable the
BRK
instruction. It can also reset the
Z8 Encore! XP
F08xA Series device.
A reset and stop function can be achieved by writing
81H
to this register. A reset
and
go
function can be achieved by writing
41H
to this register. If the device is in DEBUG mode,
a run function can be implemented by writing
40H
to this register.
.
DBGMODE--Debug Mode
The device enters DEBUG mode when this bit is 1. When in DEBUG mode, the eZ8 CPU
stops fetching new instructions. Clearing this bit causes the eZ8 CPU to restart. This bit is
automatically set when a BRK instruction is decoded and Breakpoints are enabled. If the
Flash Read Protect Option Bit is enabled, this bit can only be cleared by resetting the
device. It cannot be written to 0.
0 = The Z8 Encore! XP
F08xA Series device is operating in NORMAL mode.
1 = The Z8 Encore! XP
F08xA Series device is in DEBUG mode.
BRKEN--Breakpoint Enable
This bit controls the behavior of the
BRK
instruction (opcode
00H
). By default, Break-
points are disabled and the
BRK
instruction behaves similar to an NOP instruction. If this
bit is 1, when a
BRK
instruction is decoded, the
DBGMODE
bit of the OCDCTL register is
automatically set to 1.
0 = Breakpoints are disabled.
1 = Breakpoints are enabled.
DBGACK--Debug Acknowledge
This bit enables the debug acknowledge feature. If this bit is set to 1, the OCD sends a
Debug Acknowledge character (
FFH
) to the host when a Breakpoint occurs.
0 = Debug Acknowledge is disabled.
1 = Debug Acknowledge is enabled.
Reserved--Must be 0.
RST--Reset
Setting this bit to 1 resets the Z8 Encore! XP
F08xA Series device. The device goes
Table 99. OCD Control Register (OCDCTL)
BITS
7
6
5
4
3
2
1
0
FIELD
DBGMODE BRKEN DBGACK
Reserved
RST
RESET
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R
R
R
R
R/W
PS024705-0405
P R E L I M I N A R Y On-Chip
Debugger
Z8 Encore! XP
F08xA Series
Product Specification
159
through a normal Power-On Reset sequence with the exception that the On-Chip Debug-
ger is not reset. This bit is automatically cleared to 0 at the end of reset.
0 = No effect.
1 = Reset the Flash Read Protect Option Bit device.
OCD Status Register
The OCD Status register reports status information about the current state of the debugger
and the system.
DBG--Debug Status
0 = NORMAL mode
1 = DEBUG mode
HALT--HALT Mode
0 = Not in HALT mode
1 = In HALT mode
FRPENB--Flash Read Protect Option Bit Enable
0 = FRP bit enabled, that allows disabling of many OCD commands
1 = FRP bit has no effect
Reserved--Must be 0.
Table 100. OCD Status Register (OCDSTAT)
BITS
7
6
5
4
3
2
1
0
FIELD
DBG
HALT
FRPENB
Reserved
RESET
0
0
0
0
0
0
0
0
R/W
R
R
R
R
R
R
R
R
PS024705-0405
P R E L I M I N A R Y Oscillator
Control
Z8 Encore! XP
F08xA Series
Product Specification
160
Oscillator Control
Overview
The Z8 Encore! XP
F08xA Series devices uses five possible clocking schemes, each
user-selectable:
On-chip precision trimmed RC oscillator
On-chip oscillator using off-chip crystal or resonator
On-chip oscillator using external RC network
External clock drive
On-chip low precision Watch-Dog Timer oscillator
In addition, Z8 Encore! XP
F08xA Series devices contain clock failure detection and
recovery circuitry, allowing continued operation despite a failure of the primary oscillator.
Operation
This chapter discusses the logic used to select the system clock and handle primary oscil-
lator failures. A description of the specific operation of each oscillator is outlined else-
where in this document. The detailed description of the Watch-Dog Timer Oscillator starts
on page 79, the Internal Precision Oscillator description begins on page 169, and the chap-
ter outlining the Crystal Oscillator begins on page 165 of this document.
System Clock Selection
The oscillator control block selects from the available clocks. Table 101 details each clock
source and its usage.
PS024705-0405
P R E L I M I N A R Y Oscillator
Control
Z8 Encore! XP
F08xA Series
Product Specification
161
Unintentional accesses to the oscillator control register can actually stop the chip by
switching to a non-functioning oscillator. To prevent this condition, the oscillator con-
trol block employs a register unlocking/locking scheme.
OSC Control Register Unlocking/Locking
To write the oscillator control register, unlock it by making two writes to the OSCCTL
register with the values
E7H
followed by
18H
. A third write to the OSCCTL register
changes the value of the actual register and returns the register to a locked state. Any other
sequence of oscillator control register writes has no effect. The values written to unlock
the register must be ordered correctly, but are not necessarily consecutive. It is possible to
write to or read from other registers within the unlocking/locking operation.
Table 101. Oscillator Configuration and Selection
Clock Source
Characteristics
Required Setup
Internal Precision
RC Oscillator
32.8KHz or 5.53MHz
4% accuracy when trimmed
No external components required
Unlock and write Oscillator Control
Register (OSCCTL) to enable and
select oscillator at either 5.53MHz or
32.8KHz
External Crystal/
Resonator
32KHz to 20MHz
Very high accuracy (dependent on
crystal or resonator used)
Requires external components
Configure Flash option bits for correct
external oscillator mode
Unlock and write OSCCTL to enable
crystal oscillator, wait for it to stabilize
and select as system clock (if the
XTLDIS option bit has been de-
asserted, no waiting is required)
External RC
Oscillator
32KHz to 4MHz
Accuracy dependent on external
components
Configure Flash option bits for correct
external oscillator mode
Unlock and write OSCCTL to enable
crystal oscillator and select as system
clock
External Clock
Drive
0 to 20MHz
Accuracy dependent on external clock
source
Write GPIO registers to configure PB3
pin for external clock function
Unlock and write OSCCTL to select
external system clock
Apply external clock signal to GPIO
Internal Watchdog
Timer Oscillator
10KHz nominal
40% accuracy; no external
components required
Low power consumption
Enable WDT if not enabled and wait
until WDT Oscillator is operating.
Unlock and write Oscillator Control
Register (OSCCTL) to enable and
select oscillator
Caution:
PS024705-0405
P R E L I M I N A R Y Oscillator
Control
Z8 Encore! XP
F08xA Series
Product Specification
162
When selecting a new clock source, the primary oscillator failure detection circuitry and
the Watch-Dog Timer oscillator failure circuitry must be disabled. If POFEN and WOFEN
are not disabled prior to a clock switch-over, it is possible to generate an interrupt for a
failure of either oscillator. The Failure detection circuitry can be enabled anytime after a
successful write of OSCSEL in the oscillator control register.
The internal precision oscillator is enabled by default. If the user code changes to a differ-
ent oscillator, it may be appropriate to disable the IPO for power savings. Disabling the
IPO does not occur automatically.
Clock Failure Detection and Recovery
Primary Oscillator Failure
The Z8 Encore! XP
F08xA Series devices can generate non-maskable interrupt-like
events when the primary oscillator fails. To maintain system function in this situation, the
clock failure recovery circuitry automatically forces the Watch-Dog Timer oscillator to
drive the system clock. The Watch-Dog Timer oscillator must be enabled to allow the
recovery. Although this oscillator runs at a much slower speed than the original system
clock, the CPU continues to operate, allowing execution of a clock failure vector and soft-
ware routines that either remedy the oscillator failure or issue a failure alert. This auto-
matic switch-over is not available if the Watch-Dog Timer is the primary oscillator. It is
also unavailable if the Watch-Dog Timer oscillator is disabled, though it is not necessary
to enable the Watch-Dog Timer reset function outlined in the Watch-Dog Timer chapter of
this document on page 79.
The primary oscillator failure detection circuitry asserts if the system clock frequency
drops below 1KHz 50%. If an external signal is selected as the system oscillator, it is
possible that a very slow but non-failing clock can generate a failure condition. Under
these conditions, do not enable the clock failure circuitry (POFEN must be deasserted in
the OSCCTL register).
Watch-Dog Timer Failure
In the event of a Watch-Dog Timer oscillator failure, a similar non-maskable interrupt-like
event is issued. This event does not trigger an attendant clock switch-over, but alerts the
CPU of the failure. After a Watch-Dog Timer failure, it is no longer possible to detect a
primary oscillator failure. The failure detection circuitry does not function if the Watch-
Dog Timer is used as the primary oscillator or if the Watch-Dog Timer oscillator has been
disabled. For either of these cases, it is necessary to disable the detection circuitry by deas-
serting the WDFEN bit of the OSCCTL register.
The Watch-Dog Timer oscillator failure detection circuit counts system clocks while look-
ing for a Watch-Dog Timer clock. The logic counts 8004 system clock cycles before deter-
mining that a failure has occurred. The system clock rate determines the speed at which
PS024705-0405
P R E L I M I N A R Y Oscillator
Control
Z8 Encore! XP
F08xA Series
Product Specification
163
the Watch-Dog Timer failure can be detected. A very slow system clock results in very
slow detection times.
It is possible to disable the clock failure detection circuitry as well as all functioning
clock sources. In this case, the Z8 Encore! XP
F08xA Series device ceases functioning
and can only be recovered by Power-On-Reset.
Oscillator Control Register Definitions
Oscillator Control Register
The Oscillator Control Register (OSCCTL) enables/disables the various oscillator circuits,
enables/disables the failure detection/recovery circuitry and selects the primary oscillator,
which becomes the system clock.
The Oscillator Control Register must be unlocked before writing. Writing the two step
sequence
E7H
followed by
18H
to the Oscillator Control Register unlocks it. The register
is locked at successful completion of a register write to the OSCCTL.
INTEN--Internal Precision Oscillator Enable
1 = Internal precision oscillator is enabled
0 = Internal precision oscillator is disabled
XTLEN--Crystal Oscillator Enable; this setting overrides the GPIO register control for
PA0 and PA1
1 = Crystal oscillator is enabled
0 = Crystal oscillator is disabled
WDTEN--Watchdog Timer Oscillator Enable
1 = Watch-Dog Timer oscillator is enabled
0 = Watch-Dog Timer oscillator is disabled
POFEN--Primary Oscillator Failure Detection Enable
1 = Failure detection and recovery of primary oscillator is enabled
0 = Failure detection and recovery of primary oscillator is disabled
Table 102. Oscillator Control Register (OSCCTL)
BITS
7
6
5
4
3
2
1
0
FIELD
INTEN
XTLEN
WDTEN
POFEN
WDFEN
SCKSEL
RESET
1
0
1
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ADDR
F86H
Caution:
PS024705-0405
P R E L I M I N A R Y Oscillator
Control
Z8 Encore! XP
F08xA Series
Product Specification
164
WDFEN--Watchdog Timer Oscillator Failure Detection Enable
1 = Failure detection of Watch-Dog Timer oscillator is enabled
0 = Failure detection of Watch-Dog Timer oscillator is disabled
SCKSEL--System Clock Oscillator Select
000 = Internal precision oscillator functions as system clock at 5.53MHz
001 = Internal precision oscillator functions as system clock at 32KHz
010 = Crystal oscillator or external RC oscillator functions as system clock
011 = Watch-Dog Timer oscillator functions as system
100 = External clock signal on PB3 functions as system clock
101 = Reserved
110 = Reserved
111 = Reserved
PS024705-0405
P R E L I M I N A R Y Crystal
Oscillator
Z8 Encore! XP
F08xA Series
Product Specification
165
Crystal Oscillator
Overview
The products in the Z8 Encore! XP
F08xA Series contain an on-chip crystal oscillator for
use with external crystals with 32KHz to 20MHz frequencies. In addition, the oscillator
supports external RC networks with oscillation frequencies up to 4MHz or ceramic reso-
nators with frequencies up to 8MHz. The on-chip crystal oscillator can be used to generate
the primary system clock for the internal eZ8 CPU and the majority of the on-chip periph-
erals. Alternatively, the X
IN
input pin can also accept a CMOS-level clock input signal
(32KHz20MHz). If an external clock generator is used, the X
OUT
pin must be left uncon-
nected. The Z8 Encore! XP
F08xA Series products do not contain an internal clock
divider. The frequency of the signal on the X
IN
input pin determines the frequency of the
system clock.
Although the XIN pin can be used as an input for an external clock generator, the CLKIN
pin is better suited for such use (See "System Clock Selection" on page 160.)
Operating Modes
The Z8 Encore! XP
F08xA Series products support four oscillator modes:
Minimum power for use with very low frequency crystals (32KHz1MHz)
Medium power for use with medium frequency crystals or ceramic resonators
(0.5MHz to 8MHz)
Maximum power for use with high frequency crystals (8MHz to 20MHz)
On-chip oscillator configured for use with external RC networks (<4MHz)
The oscillator mode is selected using user-programmable Flash Option Bits. Please refer
to the chapter "Flash Option Bits" on page 138 for information.
Crystal Oscillator Operation
The Flash Option bit XTLDIS controls whether the crystal oscillator is enabled during
reset. The crystal may later be disabled after reset if a new oscillator has been selected as
the system clock. If the crystal is manually enabled after reset through the OSCCTL regis-
ter, the user code must wait at least 1000 crystal oscillator cycles for the crystal to stabi-
lize. After this, the crystal oscillator may be selected as the system clock.
Figure 25 illustrates a recommended configuration for connection with an external funda-
mental-mode, parallel-resonant crystal operating at 20MHz. Recommended 20MHz crys-
Note:
PS024705-0405
P R E L I M I N A R Y Crystal
Oscillator
Z8 Encore! XP
F08xA Series
Product Specification
166
tal specifications are provided in Table 103. Resistor R
1
is optional and limits total power
dissipation by the crystal. Printed circuit board layout must add no more than 4pF of stray
capacitance to either the X
IN
or X
OUT
pins. If oscillation does not occur, reduce the values
of capacitors C
1
and C
2
to decrease loading.
Figure 25.Recommended 20 MHz Crystal Oscillator Configuration
Table 103. Recommended Crystal Oscillator Specifications
Parameter
Value
Units
Comments
Frequency
20
MHz
Resonance
Parallel
Mode
Fundamental
Series Resistance (R
S
)
60
W
Maximum
Load Capacitance (C
L
)
30
pF
Maximum
Shunt Capacitance (C
0
)
7
pF
Maximum
Drive Level
1
mW
Maximum
C2 = 39pF
C1 = 39pF
Crystal
XOUT
XIN
On-Chip Oscillator
R1 = 220
PS024705-0405
P R E L I M I N A R Y Crystal
Oscillator
Z8 Encore! XP
F08xA Series
Product Specification
167
Oscillator Operation with an External RC Network
Figure 26 illustrates a recommended configuration for connection with an external resis-
tor-capacitor (RC) network.
Figure 26.Connecting the On-Chip Oscillator to an External RC Network
An external resistance value of 45K
is recommended for oscillator operation with an
external RC network. The minimum resistance value to ensure operation is 40K
. The
typical oscillator frequency can be estimated from the values of the resistor (R in K
) and
capacitor (C in pF) elements using the following equation:
Figure 27 illustrates the typical (3.3V and 25
0
C) oscillator frequency as a function of the
capacitor (C in pF) employed in the RC network assuming a 45K
external resistor. For
very small values of C, the parasitic capacitance of the oscillator XIN pin and the printed
circuit board should be included in the estimation of the oscillator frequency.
It is possible to operate the RC oscillator using only the parasitic capacitance of the pack-
age and printed circuit board. To minimize sensitivity to external parasitics, external
capacitance values in excess of 20pF are recommended.
C
X
IN
R
VDD
Oscillator Frequency (kHz)
1
6
10
0.4
R C
(
)
4
C
(
)
+
----------------------------------------------------------
=
PS024705-0405
P R E L I M I N A R Y Crystal
Oscillator
Z8 Encore! XP
F08xA Series
Product Specification
168
Figure 27.Typical RC Oscillator Frequency as a Function of the External Capacitance with a
45KOhm Resistor
When using the external RC oscillator mode, the oscillator can stop oscil-
lating if the power supply drops below 2.7V, but before the power supply
drops to the voltage brown-out threshold. The oscillator resumes oscilla-
tion when the supply voltage exceeds 2.7V.
0
250
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
3250
3500
3750
4000
0
20
40
60
80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500
C (pF)
F
r
eq
u
e
n
cy (
k
H
z
)
Caution:
PS024705-0405
P R E L I M I N A R Y Internal
Precision
Oscillator
Z8 Encore! XP
F08xA Series
Product Specification
169
Internal Precision Oscillator
Overview
The Internal Precision Oscillator (IPO) is designed for use without external components.
The user can either manually trim the oscillator for a non-standard frequency or use the
automatic factory-trimmed version to achieve a 5.53MHz frequency. IPO features include:
On-chip RC oscillator that does not require external components
Output frequency of either 5.53MHz or 32.8KHz (contains both a fast and a slow mode)
Trimming possible through Flash option bits with user override
Elimination of crystals or ceramic resonators in applications where high timing accuracy
is not required.
Operation
The internal oscillator is an RC relaxation oscillator that has had its sensitivity to power
supply variation minimized. By using ratio tracking thresholds, the effect of power supply
voltage is cancelled out. The dominant source of oscillator error is the absolute variance of
chip level fabricated components, such as capacitors. An 8-bit trimming register, incorpo-
rated into the design, compensates for absolute variation of oscillator frequency. Once
trimmed the oscillator frequency is stable and does not require subsequent calibration.
Trimming was performed during manufacturing and is not necessary for the user to repeat
unless a frequency other than 5.53MHz (fast mode) or 32.8kHz (slow mode) is required.
Power down this block for minimum system power.
By default, the oscillator is configured through the Flash Option bits. However, the user
code can override these trim values as described in "Trim Bit Address Space" on
page 142.
Select one of two frequencies for the oscillator: 5.53MHz and 32.8KHz, using the OSC-
SEL bits in the "Oscillator Control" on page 160.
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
170
eZ8 CPU Instruction Set
Assembly Language Programming Introduction
The eZ8 CPU assembly language provides a means for writing an application program
without concern for actual memory addresses or machine instruction formats. A program
written in assembly language is called a source program. Assembly language allows the
use of symbolic addresses to identify memory locations. It also allows mnemonic codes
(opcodes and operands) to represent the instructions themselves. The opcodes identify the
instruction while the operands represent memory locations, registers, or immediate data
values.
Each assembly language program consists of a series of symbolic commands called state-
ments. Each statement can contain labels, operations, operands and comments.
Labels can be assigned to a particular instruction step in a source program. The label iden-
tifies that step in the program as an entry point for use by other instructions.
The assembly language also includes assembler directives that supplement the machine
instruction. The assembler directives, or pseudo-ops, are not translated into a machine
instruction. Rather, the pseudo-ops are interpreted as directives that control or assist the
assembly process.
The source program is processed (assembled) by the assembler to obtain a machine lan-
guage program called the object code. The object code is executed by the eZ8 CPU. An
example segment of an assembly language program is detailed in the following example.
Assembly Language Source Program Example
JP START
; Everything after the semicolon is a comment.
START:
; A label called "START". The first instruction (
JP START
) in this
; example causes program execution to jump to the point within the
; program where the
START
label occurs.
LD R4, R7
; A Load (LD) instruction with two operands. The first operand,
; Working Register R4, is the destination. The second operand,
; Working Register R7, is the source. The contents of R7 is
; written into R4.
LD 234H, #%01
; Another Load (LD) instruction with two operands.
; The first operand, Extended Mode Register Address
234H
,
; identifies the destination. The second operand, Immediate Data
; value
01H
, is the source. The value
01H
is written into the
; Register at address
234H
.
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
171
Assembly Language Syntax
For proper instruction execution, eZ8 CPU assembly language syntax requires that the
operands be written as `destination, source'. After assembly, the object code usually has
the operands in the order 'source, destination', but ordering is opcode-dependent. The fol-
lowing instruction examples illustrate the format of some basic assembly instructions and
the resulting object code produced by the assembler. This binary format must be followed
by users that prefer manual program coding or intend to implement their own assembler.
Example 1: If the contents of Registers 43H and 08H are added and the result is stored in
43H, the assembly syntax and resulting object code is:
Example 2: In general, when an instruction format requires an 8-bit register address, that
address can specify any register location in the range 0255 or, using Escaped Mode
Addressing, a Working Register R0R15. If the contents of Register 43H and Working
Register R8 are added and the result is stored in 43H, the assembly syntax and resulting
object code is:
See the device-specific Product Specification to determine the exact register file range
available. The register file size varies, depending on the device type.
eZ8 CPU Instruction Notation
In the eZ8 CPU Instruction Summary and Description sections, the operands, condition
codes, status flags, and address modes are represented by a notational shorthand that is
described in Table 106
Table 104. Assembly Language Syntax Example 1
Assembly Language Code
ADD
43H,
08H
(ADD dst, src)
Object Code
04
08
43
(OPC src, dst)
Table 105. Assembly Language Syntax Example 2
Assembly Language Code
ADD
43H,
R8
(ADD dst, src)
Object Code
04
E8
43
(OPC src, dst)
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
172
.
Table 107 contains additional symbols that are used throughout the Instruction Summary
and Instruction Set Description sections.
Table 106. Notational Shorthand
Notation Description
Operand Range
b
Bit
b
b represents a value from 0 to 7 (000B to 111B).
cc
Condition Code
--
See Condition Codes overview in the eZ8 CPU
User Manual.
DA
Direct Address
Addrs
Addrs. represents a number in the range of
0000H to FFFFH
ER
Extended Addressing Register
Reg
Reg. represents a number in the range of 000H to
FFFH
IM
Immediate Data
#Data
Data is a number between 00H to FFH
Ir
Indirect Working Register
@Rn
n = 0 15
IR
Indirect Register
@Reg
Reg. represents a number in the range of 00H to
FFH
Irr
Indirect Working Register Pair
@RRp
p = 0, 2, 4, 6, 8, 10, 12, or 14
IRR
Indirect Register Pair
@Reg
Reg. represents an even number in the range
00H to FEH
p
Polarity
p
Polarity is a single bit binary value of either 0B or
1B.
r
Working Register
Rn
n = 0 15
R
Register
Reg
Reg. represents a number in the range of 00H to
FFH
RA
Relative Address
X
X represents an index in the range of +127 to
128 which is an offset relative to the address of
the next instruction
rr
Working Register Pair
RRp
p = 0, 2, 4, 6, 8, 10, 12, or 14
RR
Register Pair
Reg
Reg. represents an even number in the range of
00H to FEH
Vector
Vector Address
Vector
Vector represents a number in the range of 00H
to FFH
X
Indexed
#Index
The register or register pair to be indexed is offset
by the signed Index value (#Index) in a +127 to
-128 range.
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
173
Assignment of a value is indicated by an arrow. For example,
dst
dst + src
indicates the source data is added to the destination data and the result is stored in the des-
tination location.
eZ8 CPU Instruction Classes
eZ8 CPU instructions can be divided functionally into the following groups:
Arithmetic
Bit Manipulation
Block Transfer
CPU Control
Load
Logical
Program Control
Rotate and Shift
Table 107. Additional Symbols
Symbol
Definition
dst
Destination Operand
src
Source Operand
@
Indirect Address Prefix
SP
Stack Pointer
PC
Program Counter
FLAGS
Flags Register
RP
Register Pointer
#
Immediate Operand Prefix
B
Binary Number Suffix
%
Hexadecimal Number
Prefix
H
Hexadecimal Number
Suffix
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
174
Tables 108 through 115 contain the instructions belonging to each group and the number
of operands required for each instruction. Some instructions appear in more than one table
as these instruction can be considered as a subset of more than one category. Within these
tables, the source operand is identified as 'src', the destination operand is 'dst' and a con-
dition code is 'cc'.
Table 108. Arithmetic Instructions
Mnemonic
Operands
Instruction
ADC
dst, src
Add with Carry
ADCX
dst, src
Add with Carry using Extended Addressing
ADD
dst, src
Add
ADDX
dst, src
Add using Extended Addressing
CP
dst, src
Compare
CPC
dst, src
Compare with Carry
CPCX
dst, src
Compare with Carry using Extended Addressing
CPX
dst, src
Compare using Extended Addressing
DA
dst
Decimal Adjust
DEC
dst
Decrement
DECW
dst
Decrement Word
INC
dst
Increment
INCW
dst
Increment Word
MULT
dst
Multiply
SBC
dst, src
Subtract with Carry
SBCX
dst, src
Subtract with Carry using Extended Addressing
SUB
dst, src
Subtract
SUBX
dst, src
Subtract using Extended Addressing
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
175
Table 109. Bit Manipulation Instructions
Mnemonic
Operands
Instruction
BCLR
bit, dst
Bit Clear
BIT
p, bit, dst
Bit Set or Clear
BSET
bit, dst
Bit Set
BSWAP
dst
Bit Swap
CCF
--
Complement Carry Flag
RCF
--
Reset Carry Flag
SCF
--
Set Carry Flag
TCM
dst, src
Test Complement Under Mask
TCMX
dst, src
Test Complement Under Mask using Extended Addressing
TM
dst, src
Test Under Mask
TMX
dst, src
Test Under Mask using Extended Addressing
Table 110. Block Transfer Instructions
Mnemonic
Operands
Instruction
LDCI
dst, src
Load Constant to/from Program Memory and Auto-Increment Addresses
LDEI
dst, src
Load External Data to/from Data Memory and Auto-Increment Addresses
Table 111. CPU Control Instructions
Mnemonic
Operands
Instruction
ATM
--
Atomic Execution
CCF
--
Complement Carry Flag
DI
--
Disable Interrupts
EI
--
Enable Interrupts
HALT
--
Halt Mode
NOP
--
No Operation
RCF
--
Reset Carry Flag
SCF
--
Set Carry Flag
SRP
src
Set Register Pointer
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
176
STOP
--
STOP Mode
WDT
--
Watch-Dog Timer Refresh
Table 112. Load Instructions
Mnemonic Operands Instruction
CLR
dst
Clear
LD
dst, src
Load
LDC
dst, src
Load Constant to/from Program Memory
LDCI
dst, src
Load Constant to/from Program Memory and Auto-Increment
Addresses
LDE
dst, src
Load External Data to/from Data Memory
LDEI
dst, src
Load External Data to/from Data Memory and Auto-Increment
Addresses
LDWX
dst, src
Load Word using Extended Addressing
LDX
dst, src
Load using Extended Addressing
LEA
dst, X(src) Load Effective Address
POP
dst
Pop
POPX
dst
Pop using Extended Addressing
PUSH
src
Push
PUSHX
src
Push using Extended Addressing
Table 113. Logical Instructions
Mnemonic Operands Instruction
AND
dst, src
Logical AND
ANDX
dst, src
Logical AND using Extended Addressing
COM
dst
Complement
OR
dst, src
Logical OR
ORX
dst, src
Logical OR using Extended Addressing
Table 111. CPU Control Instructions
Mnemonic
Operands
Instruction
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
177
XOR
dst, src
Logical Exclusive OR
XORX
dst, src
Logical Exclusive OR using Extended Addressing
Table 114. Program Control Instructions
Mnemonic
Operands
Instruction
BRK
--
On-Chip Debugger Break
BTJ
p, bit, src, DA Bit Test and Jump
BTJNZ
bit, src, DA
Bit Test and Jump if Non-Zero
BTJZ
bit, src, DA
Bit Test and Jump if Zero
CALL
dst
Call Procedure
DJNZ
dst, src, RA
Decrement and Jump Non-Zero
IRET
--
Interrupt Return
JP
dst
Jump
JP cc
dst
Jump Conditional
JR
DA
Jump Relative
JR cc
DA
Jump Relative Conditional
RET
--
Return
TRAP
vector
Software Trap
Table 115. Rotate and Shift Instructions
Mnemonic
Operands
Instruction
BSWAP
dst
Bit Swap
RL
dst
Rotate Left
RLC
dst
Rotate Left through Carry
RR
dst
Rotate Right
RRC
dst
Rotate Right through Carry
SRA
dst
Shift Right Arithmetic
Table 113. Logical Instructions
Mnemonic Operands Instruction
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
178
eZ8 CPU Instruction Summary
Table 116 summarizes the eZ8 CPU instructions. The table identifies the addressing
modes employed by the instruction, the effect upon the Flags register, the number of CPU
clock cycles required for the instruction fetch, and the number of CPU clock cycles
required for the instruction execution.
.
SRL
dst
Shift Right Logical
SWAP
dst
Swap Nibbles
Table 116. eZ8 CPU Instruction Summary
Assembly
Mnemonic
Symbolic Operation
Address Mode
Opcode(s)
(Hex)
Flags
Fetch
Cycles
Instr.
Cycles
dst
src
C Z S V D
H
ADC dst, src
dst
dst + src + C
r
r
12
*
*
*
*
0
*
2
3
r
Ir
13
2
4
R
R
14
3
3
R
IR
15
3
4
R
IM
16
3
3
IR
IM
17
3
4
ADCX dst, src
dst
dst + src + C
ER
ER
18
*
*
*
*
0
*
4
3
ER
IM
19
4
3
ADD dst, src
dst
dst + src
r
r
02
*
*
*
*
0
*
2
3
r
Ir
03
2
4
R
R
04
3
3
R
IR
05
3
4
R
IM
06
3
3
IR
IM
07
3
4
ADDX dst, src
dst
dst + src
ER
ER
08
*
*
*
*
0
*
4
3
ER
IM
09
4
3
Flags Notation:
* = Value is a function of the result of the operation.
= Unaffected
X = Undefined
0 = Reset to 0
1 = Set to 1
Table 115. Rotate and Shift Instructions
Mnemonic
Operands
Instruction
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
179
AND dst, src
dst
dst AND src
r
r
52
*
*
0
2
3
r
Ir
53
2
4
R
R
54
3
3
R
IR
55
3
4
R
IM
56
3
3
IR
IM
57
3
4
ANDX dst, src
dst
dst AND src
ER
ER
58
*
*
0
4
3
ER
IM
59
4
3
ATM
Block all interrupt and
DMA requests during
execution of the next 3
instructions
2F
1
2
BCLR bit, dst
dst[bit]
0
r
E2
*
*
0
2
2
BIT p, bit, dst
dst[bit]
p
r
E2
*
*
0
2
2
BRK
Debugger Break
00
1
1
BSET bit, dst
dst[bit]
1
r
E2
*
*
0
2
2
BSWAP dst
dst[7:0]
dst[0:7]
R
D5
X
*
*
0
2
2
BTJ p, bit, src, dst if src[bit] = p
PC
PC + X
r
F6
3
3
Ir
F7
3
4
BTJNZ bit, src, dst if src[bit] = 1
PC
PC + X
r
F6
3
3
Ir
F7
3
4
BTJZ bit, src, dst
if src[bit] = 0
PC
PC + X
r
F6
3
3
Ir
F7
3
4
CALL dst
SP
SP -2
@SP
PC
PC
dst
IRR
D4
2
6
DA
D6
3
3
CCF
C
~C
EF
*
-
1
2
CLR dst
dst
00H
R
B0
2
2
IR
B1
2
3
Table 116. eZ8 CPU Instruction Summary (Continued)
Assembly
Mnemonic
Symbolic Operation
Address Mode
Opcode(s)
(Hex)
Flags
Fetch
Cycles
Instr.
Cycles
dst
src
C Z S V D
H
Flags Notation:
* = Value is a function of the result of the operation.
= Unaffected
X = Undefined
0 = Reset to 0
1 = Set to 1
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
180
COM dst
dst
~dst
R
60
*
*
0
2
2
IR
61
2
3
CP dst, src
dst - src
r
r
A2
*
*
*
*
2
3
r
Ir
A3
2
4
R
R
A4
3
3
R
IR
A5
3
4
R
IM
A6
3
3
IR
IM
A7
3
4
CPC dst, src
dst - src - C
r
r
1F A2
*
*
*
*
3
3
r
Ir
1F A3
3
4
R
R
1F A4
4
3
R
IR
1F A5
4
4
R
IM
1F A6
4
3
IR
IM
1F A7
4
4
CPCX dst, src
dst - src - C
ER
ER
1F A8
*
*
*
*
5
3
ER
IM
1F A9
5
3
CPX dst, src
dst - src
ER
ER
A8
*
*
*
*
4
3
ER
IM
A9
4
3
DA dst
dst
DA(dst)
R
40
*
*
*
X
2
2
IR
41
2
3
DEC dst
dst
dst - 1
R
30
*
*
*
2
2
IR
31
2
3
DECW dst
dst
dst - 1
RR
80
*
*
*
2
5
IRR
81
2
6
DI
IRQCTL[7]
0
8F
1
2
DJNZ dst, RA
dst
dst 1
if dst
0
PC
PC + X
r
0A-FA
2
3
EI
IRQCTL[7]
1
9F
1
2
Table 116. eZ8 CPU Instruction Summary (Continued)
Assembly
Mnemonic
Symbolic Operation
Address Mode
Opcode(s)
(Hex)
Flags
Fetch
Cycles
Instr.
Cycles
dst
src
C Z S V D
H
Flags Notation:
* = Value is a function of the result of the operation.
= Unaffected
X = Undefined
0 = Reset to 0
1 = Set to 1
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
181
HALT
Halt Mode
7F
1
2
INC dst
dst
dst + 1
R
20
*
*
2
2
IR
21
2
3
r
0E-FE
1
2
INCW dst
dst
dst + 1
RR
A0
*
*
*
2
5
IRR
A1
2
6
IRET
FLAGS
@SP
SP
SP + 1
PC
@SP
SP
SP + 2
IRQCTL[7]
1
BF
*
*
*
*
*
*
1
5
JP dst
PC
dst
DA
8D
3
2
IRR
C4
2
3
JP cc, dst
if cc is true
PC
dst
DA
0D-FD
3
2
JR dst
PC
PC + X
DA
8B
2
2
JR cc, dst
if cc is true
PC
PC + X
DA
0B-FB
2
2
LD dst, rc
dst
src
r
IM
0C-FC
2
2
r
X(r)
C7
3
3
X(r)
r
D7
3
4
r
Ir
E3
2
3
R
R
E4
3
2
R
IR
E5
3
4
R
IM
E6
3
2
IR
IM
E7
3
3
Ir
r
F3
2
3
IR
R
F5
3
3
Table 116. eZ8 CPU Instruction Summary (Continued)
Assembly
Mnemonic
Symbolic Operation
Address Mode
Opcode(s)
(Hex)
Flags
Fetch
Cycles
Instr.
Cycles
dst
src
C Z S V D
H
Flags Notation:
* = Value is a function of the result of the operation.
= Unaffected
X = Undefined
0 = Reset to 0
1 = Set to 1
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
182
LDC dst, src
dst
src
r
Irr
C2
2
5
Ir
Irr
C5
2
9
Irr
r
D2
2
5
LDCI dst, src
dst
src
r
r + 1
rr
rr + 1
Ir
Irr
C3
2
9
Irr
Ir
D3
2
9
LDE dst, src
dst
src
r
Irr
82
2
5
Irr
r
92
2
5
LDEI dst, src
dst
src
r
r + 1
rr
rr + 1
Ir
Irr
83
2
9
Irr
Ir
93
2
9
LDWX dst, src
dst
src
ER
ER
1FE8
5
4
LDX dst, src
dst
src
r
ER
84
3
2
Ir
ER
85
3
3
R
IRR
86
3
4
IR
IRR
87
3
5
r
X(rr)
88
3
4
X(rr)
r
89
3
4
ER
r
94
3
2
ER
Ir
95
3
3
IRR
R
96
3
4
IRR
IR
97
3
5
ER
ER
E8
4
2
ER
IM
E9
4
2
LEA dst, X(src)
dst
src + X
r
X(r)
98
3
3
rr
X(rr)
99
3
5
MULT dst
dst[15:0]
dst[15:8] * dst[7:0]
RR
F4
2
8
NOP
No operation
0F
1
2
Table 116. eZ8 CPU Instruction Summary (Continued)
Assembly
Mnemonic
Symbolic Operation
Address Mode
Opcode(s)
(Hex)
Flags
Fetch
Cycles
Instr.
Cycles
dst
src
C Z S V D
H
Flags Notation:
* = Value is a function of the result of the operation.
= Unaffected
X = Undefined
0 = Reset to 0
1 = Set to 1
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
183
OR dst, src
dst
dst OR src
r
r
42
*
*
0
2
3
r
Ir
43
2
4
R
R
44
3
3
R
IR
45
3
4
R
IM
46
3
3
IR
IM
47
3
4
ORX dst, src
dst
dst OR src
ER
ER
48
*
*
0
4
3
ER
IM
49
4
3
POP dst
dst
@SP
SP
SP + 1
R
50
2
2
IR
51
2
3
POPX dst
dst
@SP
SP
SP + 1
ER
D8
3
2
PUSH src
SP
SP 1
@SP
src
R
70
2
2
IR
71
2
3
IM
IF70
3
2
PUSHX src
SP
SP 1
@SP
src
ER
C8
3
2
RCF
C
0
CF
0
1
2
RET
PC
@SP
SP
SP + 2
AF
1
4
RL dst
R
90
*
*
*
*
2
2
IR
91
2
3
RLC dst
R
10
*
*
*
*
2
2
IR
11
2
3
RR dst
R
E0
*
*
*
*
2
2
IR
E1
2
3
Table 116. eZ8 CPU Instruction Summary (Continued)
Assembly
Mnemonic
Symbolic Operation
Address Mode
Opcode(s)
(Hex)
Flags
Fetch
Cycles
Instr.
Cycles
dst
src
C Z S V D
H
Flags Notation:
* = Value is a function of the result of the operation.
= Unaffected
X = Undefined
0 = Reset to 0
1 = Set to 1
D7 D6 D5 D4 D3 D2 D1 D0
dst
C
D7 D6 D5 D4 D3 D2 D1 D0
dst
C
D7 D6 D5 D4 D3 D2 D1 D0
dst
C
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
184
RRC dst
R
C0
*
*
*
*
2
2
IR
C1
2
3
SBC dst, src
dst
dst src - C
r
r
32
*
*
*
*
1
*
2
3
r
Ir
33
2
4
R
R
34
3
3
R
IR
35
3
4
R
IM
36
3
3
IR
IM
37
3
4
SBCX dst, src
dst
dst src - C
ER
ER
38
*
*
*
*
1
*
4
3
ER
IM
39
4
3
SCF
C
1
DF
1
1
2
SRA dst
R
D0
*
*
*
0
2
2
IR
D1
2
3
SRL dst
R
1F C0
*
*
0
*
3
2
IR
1F C1
3
3
SRP src
RP
src
IM
01
2
2
STOP
STOP Mode
6F
1
2
SUB dst, src
dst
dst src
r
r
22
*
*
*
*
1
*
2
3
r
Ir
23
2
4
R
R
24
3
3
R
IR
25
3
4
R
IM
26
3
3
IR
IM
27
3
4
SUBX dst, src
dst
dst src
ER
ER
28
*
*
*
*
1
*
4
3
ER
IM
29
4
3
Table 116. eZ8 CPU Instruction Summary (Continued)
Assembly
Mnemonic
Symbolic Operation
Address Mode
Opcode(s)
(Hex)
Flags
Fetch
Cycles
Instr.
Cycles
dst
src
C Z S V D
H
Flags Notation:
* = Value is a function of the result of the operation.
= Unaffected
X = Undefined
0 = Reset to 0
1 = Set to 1
D7 D6 D5 D4 D3 D2 D1 D0
dst
C
D7 D6 D5 D4 D3 D2 D1 D0
dst
C
D7 D6 D5 D4 D3 D2 D1 D0
dst
C
0
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
185
SWAP dst
dst[7:4]
dst[3:0]
R
F0
X
*
*
X
2
2
IR
F1
2
3
TCM dst, src
(NOT dst) AND src
r
r
62
*
*
0
2
3
r
Ir
63
2
4
R
R
64
3
3
R
IR
65
3
4
R
IM
66
3
3
IR
IM
67
3
4
TCMX dst, src
(NOT dst) AND src
ER
ER
68
*
*
0
4
3
ER
IM
69
4
3
TM dst, src
dst AND src
r
r
72
*
*
0
2
3
r
Ir
73
2
4
R
R
74
3
3
R
IR
75
3
4
R
IM
76
3
3
IR
IM
77
3
4
TMX dst, src
dst AND src
ER
ER
78
*
*
0
4
3
ER
IM
79
4
3
TRAP Vector
SP
SP 2
@SP
PC
SP
SP 1
@SP
FLAGS
PC
@Vector
Vector
F2
2
6
WDT
5F
1
2
XOR dst, src
dst
dst XOR src
r
r
B2
*
*
0
2
3
r
Ir
B3
2
4
R
R
B4
3
3
R
IR
B5
3
4
R
IM
B6
3
3
IR
IM
B7
3
4
Table 116. eZ8 CPU Instruction Summary (Continued)
Assembly
Mnemonic
Symbolic Operation
Address Mode
Opcode(s)
(Hex)
Flags
Fetch
Cycles
Instr.
Cycles
dst
src
C Z S V D
H
Flags Notation:
* = Value is a function of the result of the operation.
= Unaffected
X = Undefined
0 = Reset to 0
1 = Set to 1
PS024705-0405
P R E L I M I N A R Y
eZ8 CPU Instruction Set
Z8 Encore! XP
F08xA Series
Product Specification
186
XORX dst, src
dst
dst XOR src
ER
ER
B8
*
*
0
4
3
ER
IM
B9
4
3
Table 116. eZ8 CPU Instruction Summary (Continued)
Assembly
Mnemonic
Symbolic Operation
Address Mode
Opcode(s)
(Hex)
Flags
Fetch
Cycles
Instr.
Cycles
dst
src
C Z S V D
H
Flags Notation:
* = Value is a function of the result of the operation.
= Unaffected
X = Undefined
0 = Reset to 0
1 = Set to 1
PS024705-0405
P R E L I M I N A R Y Opcode
Maps
Z8 Encore! XP
F08xA Series
Product Specification
187
Opcode Maps
A description of the opcode map data and the abbreviations are provided in Figure 28.
Figures 29 and 32 provide information about each of the eZ8 CPU instructions. Table 117
lists Opcode Map abbreviations.
Figure 28.Opcode Map Cell Description
CP
3.3
R2,R1
A
4
Opcode
Lower Nibble
Second Operand
After Assembly
First Operand
After Assembly
Opcode
Upper Nibble
Instruction Cycles
Fetch Cycles
PS024705-0405
P R E L I M I N A R Y Opcode
Maps
Z8 Encore! XP
F08xA Series
Product Specification
188
Table 117. Opcode Map Abbreviations
Abbreviation
Description
Abbreviation
Description
b
Bit position
IRR
Indirect Register Pair
cc
Condition code
p
Polarity (0 or 1)
X
8-bit signed index or
displacement
r
4-bit Working Register
DA
Destination address
R
8-bit register
ER
Extended Addressing register
r1, R1, Ir1, Irr1, IR1,
rr1, RR1, IRR1, ER1
Destination address
IM
Immediate data value
r2, R2, Ir2, Irr2, IR2,
rr2, RR2, IRR2, ER2
Source address
Ir
Indirect Working Register
RA
Relative
IR
Indirect register
rr
Working Register Pair
Irr
Indirect Working Register Pair RR
Register Pair
PS024705-0405
P R E L I M I N A R Y Opcode
Maps
Z8 Encore! XP
F08xA Series
Product Specification
189
Figure 29.First Opcode Map
CP
3.3
R2,R1
CP
3.4
IR2,R1
CP
2.3
r1,r2
CP
2.4
r1,Ir2
CPX
4.3
ER2,ER1
CPX
4.3
IM,ER1
CP
3.3
R1,IM
CP
3.4
IR1,IM
RRC
2.2
R1
RRC
2.3
IR1
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Lower Nibble (Hex)
Up
per
Nibble (
H
ex
)
BRK
1.1
SRP
2.2
IM
ADD
2.3
r1,r2
ADD
2.4
r1,Ir2
ADD
3.3
R2,R1
ADD
3.4
IR2,R1
ADD
3.3
R1,IM
ADD
3.4
IR1,IM
ADDX
4.3
ER2,ER1
ADDX
4.3
IM,ER1
DJNZ
2.3
r1,X
JR
2.2
cc,X
LD
2.2
r1,IM
JP
3.2
cc,DA
INC
1.2
r1
NOP
1.2
RLC
2.2
R1
RLC
2.3
IR1
ADC
2.3
r1,r2
ADC
2.4
r1,Ir2
ADC
3.3
R2,R1
ADC
3.4
IR2,R1
ADC
3.3
R1,IM
ADC
3.4
IR1,IM
ADCX
4.3
ER2,ER1
ADCX
4.3
IM,ER1
INC
2.2
R1
INC
2.3
IR1
SUB
2.3
r1,r2
SUB
2.4
r1,Ir2
SUB
3.3
R2,R1
SUB
3.4
IR2,R1
SUB
3.3
R1,IM
SUB
3.4
IR1,IM
SUBX
4.3
ER2,ER1
SUBX
4.3
IM,ER1
DEC
2.2
R1
DEC
2.3
IR1
SBC
2.3
r1,r2
SBC
2.4
r1,Ir2
SBC
3.3
R2,R1
SBC
3.4
IR2,R1
SBC
3.3
R1,IM
SBC
3.4
IR1,IM
SBCX
4.3
ER2,ER1
SBCX
4.3
IM,ER1
DA
2.2
R1
DA
2.3
IR1
OR
2.3
r1,r2
OR
2.4
r1,Ir2
OR
3.3
R2,R1
OR
3.4
IR2,R1
OR
3.3
R1,IM
OR
3.4
IR1,IM
ORX
4.3
ER2,ER1
ORX
4.3
IM,ER1
POP
2.2
R1
POP
2.3
IR1
AND
2.3
r1,r2
AND
2.4
r1,Ir2
AND
3.3
R2,R1
AND
3.4
IR2,R1
AND
3.3
R1,IM
AND
3.4
IR1,IM
ANDX
4.3
ER2,ER1
ANDX
4.3
IM,ER1
COM
2.2
R1
COM
2.3
IR1
TCM
2.3
r1,r2
TCM
2.4
r1,Ir2
TCM
3.3
R2,R1
TCM
3.4
IR2,R1
TCM
3.3
R1,IM
TCM
3.4
IR1,IM
TCMX
4.3
ER2,ER1
TCMX
4.3
IM,ER1
PUSH
2.2
R2
PUSH
2.3
IR2
TM
2.3
r1,r2
TM
2.4
r1,Ir2
TM
3.3
R2,R1
TM
3.4
IR2,R1
TM
3.3
R1,IM
TM
3.4
IR1,IM
TMX
4.3
ER2,ER1
TMX
4.3
IM,ER1
DECW
2.5
RR1
DECW
2.6
IRR1
LDE
2.5
r1,Irr2
LDEI
2.9
Ir1,Irr2
LDX
3.2
r1,ER2
LDX
3.3
Ir1,ER2
LDX
3.4
IRR2,R1
LDX
3.5
IRR2,IR1
LDX
3.4
r1,rr2,X
LDX
3.4
rr1,r2,X
RL
2.2
R1
RL
2.3
IR1
LDE
2.5
r2,Irr1
LDEI
2.9
Ir2,Irr1
LDX
3.2
r2,ER1
LDX
3.3
Ir2,ER1
LDX
3.4
R2,IRR1
LDX
3.5
IR2,IRR1
LEA
3.3
r1,r2,X
LEA
3.5
rr1,rr2,X
INCW
2.5
RR1
INCW
2.6
IRR1
CLR
2.2
R1
CLR
2.3
IR1
XOR
2.3
r1,r2
XOR
2.4
r1,Ir2
XOR
3.3
R2,R1
XOR
3.4
IR2,R1
XOR
3.3
R1,IM
XOR
3.4
IR1,IM
XORX
4.3
ER2,ER1
XORX
4.3
IM,ER1
LDC
2.5
r1,Irr2
LDCI
2.9
Ir1,Irr2
LDC
2.5
r2,Irr1
LDCI
2.9
Ir2,Irr1
JP
2.3
IRR1
LDC
2.9
Ir1,Irr2
LD
3.4
r1,r2,X
PUSHX
3.2
ER2
SRA
2.2
R1
SRA
2.3
IR1
POPX
3.2
ER1
LD
3.4
r2,r1,X
CALL
2.6
IRR1
BSWAP
2.2
R1
CALL
3.3
DA
LD
3.2
R2,R1
LD
3.3
IR2,R1
BIT
2.2
p,b,r1
LD
2.3
r1,Ir2
LDX
4.2
ER2,ER1
LDX
4.2
IM,ER1
LD
3.2
R1,IM
LD
3.3
IR1,IM
RR
2.2
R1
RR
2.3
IR1
MULT
2.8
RR1
LD
3.3
R2,IR1
TRAP
2.6
Vector
LD
2.3
Ir1,r2
BTJ
3.3
p,b,r1,X
BTJ
3.4
p,b,Ir1,X
SWAP
2.2
R1
SWAP
2.3
IR1
RCF
1.2
WDT
1.2
STOP
1.2
HALT
1.2
DI
1.2
EI
1.2
RET
1.4
IRET
1.5
SCF
1.2
CCF
1.2
Opcode
See 2nd
Map
1, 2
ATM
PS024705-0405
P R E L I M I N A R Y Opcode
Maps
Z8 Encore! XP
F08xA Series
Product Specification
190
Figure 30.Second Opcode Map after 1FH
CPC
4.3
R2,R1
CPC
4.4
IR2,R1
CPC
3.3
r1,r2
CPC
3.4
r1,Ir2
CPCX
5.3
ER2,ER1
CPCX
5.3
IM,ER1
CPC
4.3
R1,IM
CPC
4.4
IR1,IM
SRL
3.2
R1
SRL
3.3
IR1
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Lower Nibble (Hex)
Upp
e
r Nib
b
le
(He
x
)
3, 2
PUSH
IM
LDWX
5, 4
ER2,ER1
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
191
Electrical Characteristics
The data in this chapter is pre-qualification and pre-characterization and is subject to
change. Additional electrical characteristics may be found in the individual chapters.
Absolute Maximum Ratings
Stresses greater than those listed in Table 118 may cause permanent damage to the device.
These ratings are stress ratings only. Operation of the device at any condition outside those
indicated in the operational sections of these specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
For improved reliability, tie unused inputs to one of the supply voltages (V
DD
or V
SS
).
Table 118. Absolute Maximum Ratings
Parameter
Minimum
Maximum
Units
Notes
Ambient temperature under bias
0
+105
C
1
Storage temperature
-65
+150
C
Voltage on any pin with respect to V
SS
-0.3
+5.5
V
2
Voltage on V
DD
pin with respect to V
SS
-0.3
+3.6
V
Maximum current on input and/or inactive output pin
-5
+5
A
Maximum output current from active output pin
-25
+25
mA
20-pin Packages Maximum Ratings at 0C to 70C
Total power dissipation
430
mW
Maximum current into V
DD
or out of V
SS
120
mA
28-pin Packages Maximum Ratings at 0C to 70C
Total power dissipation
450
mW
Maximum current into V
DD
or out of V
SS
125
mA
Operating temperature is specified in DC Characteristics
1. This voltage applies to all pins except the following: V
DD
, AV
DD
, pins supporting analog input (Port B[5:0], Port
C[2:0]) and pins supporting the crystal oscillator (PA0 and PA1). On the 8-pin packages, this applies to all pins
but V
DD
.
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
192
DC Characteristics
Table 119 lists the DC characteristics of the Z8 Encore! XP
F08xA Series products. All
voltages are referenced to V
SS
, the primary system ground.
Table 119. DC Characteristics
Symbol Parameter
T
A
= -40C to +105C
Units Conditions
Minimum
Typical
Maximum
V
DD
Supply Voltage
2.7
3.6
V
V
IL1
Low Level Input Voltage
-0.3
0.3*V
DD
V
For all input pins except RESET.
V
IL2
Low Level Input Voltage
-0.3
0.8
V
For RESET.
V
IH1
High Level Input Voltage
2.0
5.5
V
For all input pins without analog
or oscillator function.
V
IH2
High Level Input Voltage
2.0
V
DD
+0.3
V
For those pins with analog or
oscillator function.
V
OL1
Low Level Output
Voltage
0.4
V
I
OL
= 2mA; V
DD
= 3.0V
High Output Drive disabled.
V
OH1
High Level Output
Voltage
2.4
V
I
OH
= -2mA; V
DD
= 3.0V
High Output Drive disabled.
V
OL2
Low Level Output
Voltage
0.6
V
I
OL
= 20mA; V
DD
= 3.3V
High Output Drive enabled.
V
OH2
High Level Output
Voltage
2.4
V
I
OH
= -20mA; V
DD
= 3.3V
High Output Drive enabled.
I
IL
Input Leakage Current
-5
+5
A V
DD
= 3.6V;
V
IN
= V
DD
or VSS
1
I
TL
Tristate Leakage Current
-5
+5
A V
DD
= 3.6V
I
LED
Controlled Current Drive
1.8
3
4.5
mA {AFS2,AFS1} = {0,0}
2.8
7
10.5
mA {AFS2,AFS1} = {0,1}
7.8
13
19.5
mA {AFS2,AFS1} = {1,0}
12
20
30
mA {AFS2,AFS1} = {1,1}
C
PAD
GPIO Port Pad
Capacitance
8.0
2
pF TBD
C
XIN
XIN Pad Capacitance
8.0
2
pF TBD
C
XOUT
XOUT Pad Capacitance
9.5
2
pF TBD
I
PU
Weak Pull-up Current
30
100
350
A V
DD
= 3.0 - 3.6V
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
193
Figure 31 illustrates the typical current consumption while operating at 25C, 3.3V, versus
the system clock frequency.
ICCH
Supply Current in Halt
Mode
TBD
mA
TBD
ICCS
Supply Current in STOP
Mode
2
A With watchdog timer running
1
This condition excludes all pins that have on-chip pull-ups, when driven Low.
2
These values are provided for design guidance only and are not tested in production.
Figure 31. ICC Versus System Clock Frequency
Table 119. DC Characteristics (Continued)
Symbol Parameter
T
A
= -40C to +105C
Units Conditions
Minimum
Typical
Maximum
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
194
AC Characteristics
The section provides information about the AC characteristics and timing. All AC timing
information assumes a standard load of 50pF on all outputs.
Table 120. AC Characteristics
Symbol
Parameter
V
DD
= 2.7 to 3.6V
T
A
= -40C to +105C
Units
Conditions
Minimum Maximum
F
SYSCLK
System Clock Frequency
20.0
MHz
Read-only from Flash memory
0.032768
20.0
MHz
Program or erasure of the
Flash memory
F
XTAL
Crystal Oscillator Frequency
1.0
20.0
MHz
System clock frequencies
below the crystal oscillator
minimum require an external
clock driver.
F
IPO
Internal Precision Oscillator
Frequency
0.032768 5.5296
MHz
Oscillator is not adjustable over
the entire range. User may
select Min or Max value only.
F
IPO
Internal Precision Oscillator
Frequency
5.31
5.75
MHz
High speed with trimming
F
IPO
Internal Precision Oscillator
Frequency
4.15
6.91
MHz
High speed without trimming
F
IPO
Internal Precision Oscillator
Frequency
30.7
33.3
KHz
Low speed with trimming
F
IPO
Internal Precision Oscillator
Frequency
24
40
KHz
Low speed without trimming
T
XIN
System Clock Period
50
ns
T
CLK
= 1/F
sysclk
T
XINH
System Clock High Time
20
30
ns
T
CLK
= 50ns
T
XINL
System Clock Low Time
20
30
ns
T
CLK
= 50ns
T
XINR
System Clock Rise Time
3
ns
T
CLK
= 50ns
T
XINF
System Clock Fall Time
3
ns
T
CLK
= 50ns
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
195
On-Chip Peripheral AC and DC Electrical Characteristics
Table 121. Power-On Reset and Voltage Brown-Out Electrical Characteristics and Timing
Symbol Parameter
T
A
= -40C to +105C
Units
Conditions
Minimum
Typical
1
Maximum
V
POR
Power-On Reset Voltage
Threshold
2.20
2.45
2.70
V
V
DD
= V
POR
(default VBO
trim)
V
VBO
Voltage Brown-Out
Reset Voltage Threshold
2.15
2.40
2.65
V
V
DD
= V
VBO
(default VBO
trim)
V
POR
to V
VBO
hysteresis
50
75
mV
Starting V
DD
voltage to
ensure valid Power-On
Reset.
V
SS
V
T
ANA
Power-On Reset Analog
Delay
50
s
V
DD
> V
POR
; T
POR
Digital
Reset delay follows T
ANA
T
POR
Power-On Reset Digital
Delay
TBD
16
TBD
s
66 Internal Precision
Oscillator cycles
T
POR
Power-On Reset Digital
Delay
TBD
1
TBD
ms
5000 Internal Precision
Oscillator cycles
T
SMR
STOP Mode Recovery
with crystal oscillator
disabled
TBD
16
TBD
s
66 Internal Precision
Oscillator cycles
T
SMR
STOP Mode Recovery
with crystal oscillator
enabled
TBD
1
TBD
ms
5000 Internal Precision
Oscillator cycles
T
VBO
Voltage Brown-Out
Pulse Rejection Period
10
s
V
DD
< V
VBO
to generate a
Reset.
T
RAMP
Time for V
DD
to transition
from V
SS
to V
POR
to
ensure valid Reset
0.10
100
ms
1 Data in the typical column is from characterization at 3.3V and 0C. These values are provided for
design guidance only and are not tested in production.
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
196
Table 122. Flash Memory Electrical Characteristics and Timing
Parameter
V
DD
= 2.7 to 3.6V
T
A
= -40C to +105C
Units
Notes
Minimum
Typical
Maximum
Flash Byte Read Time
100
ns
Flash Byte Program Time
20
40
s
Flash Page Erase Time
10
ms
Flash Mass Erase Time
200
ms
Writes to Single Address
Before Next Erase
2
Flash Row Program Time
8
ms
Cumulative program time for
single row cannot exceed limit
before next erase. This
parameter is only an issue
when bypassing the Flash
Controller.
Data Retention
100
years 25C
Endurance
10,000
cycles Program / erase cycles
Table 123. Watch-Dog Timer Electrical Characteristics and Timing
Symbol
Parameter
V
DD
= 2.7 - 3.6V
T
A
= -40C to +105C
Units
Conditions
Minimum
Typical
Maximum
F
WDT
WDT Oscillator Frequency
10
KHz
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
197
Table 124. Analog-to-Digital Converter Electrical Characteristics and Timing
Symbol
Parameter
V
DD
= 2.7 to 3.6V
T
A
= -40C to +105C
Units
Conditions
Minimum
Typical
Maximum
Resolution
10
bits
External V
REF
= 3.0V;
R
S
3.0K
Differential Nonlinearity
(DNL)
-1.0
1.0
LSB
External V
REF
= 3.0V;
R
S
3.0K
Integral Nonlinearity (INL)
-3.0
3.0
LSB
External V
REF
= 3.0V;
R
S
3.0K
Uncalibrated DC Offset
Error (single-ended)
-100
TBD
-250
80
TBD
250
mV
Unbuffered Mode
Unity Gain Buffered
20x Gain Buffered
Note: All values are
uncompensated;
manual offset
compensation is
available
Uncalibrated DC Offset
Error (differential)
-100
TBD
80
TBD
mV
Unbuffered Mode
Unity Gain Buffered
Note: All values are
uncompensated;
manual offset
compensation is
available
V
REF
Internal Reference Voltage
0.9
1.8
1.0
2.0
1.1
2.2
V
REFSEL=00
REFSEL=01
Single-Shot Conversion
Time
5129
cycles System clock cycles
Continuous Conversion
Time
256
cycles System clock cycles
Sampling Rate
System Clock /256
Hz
Signal Input Bandwidth
10
KHz
As defined by -3dB
point
R
S
Analog Source Impedance
10
500
k
In unbuffered mode
In buffered modes
1
Analog source impedance affects the ADC offset voltage (because of pin leakage) and input settling
time.
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
198
Zin
Input Impedance
TBD
10
150
TBD
k
W
M
In unbuffered mode
In buffered modes
Vin
Input Voltage Range
0
300mV
V
DD
V
DD
-400mV
V
Unbuffered Mode
Buffered Modes
Note: these values
define the range over
which the ADC
performs within spec;
exceeding these values
does not cause
damage or instability;
see "DC
Characteristics" on
page 192 for absolute
pin voltage limits
Av
Transimpedance
Amplifier, Open loop
voltage gain
80
dB
GBW
Transimpedance
Amplifier, Gain/Bandwidth
product
1
MHz
PM
Phase Margin
53
deg
Assuming 13pF pin
capacitance
V
osTA
Transimpedance Amplifier
Input Offset Voltage
4
4
mV
Table 124. Analog-to-Digital Converter Electrical Characteristics and Timing (Continued)
Symbol
Parameter
V
DD
= 2.7 to 3.6V
T
A
= -40C to +105C
Units
Conditions
Minimum
Typical
Maximum
1
Analog source impedance affects the ADC offset voltage (because of pin leakage) and input settling
time.
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
199
Table 125. Comparator Electrical Characteristics
V
osTA
Transimpedance Amplifier
Input Offset Voltage
(Temperature Drift)
1
10
V/C Over the range of
-10C to +40C
I
outTA
Transimpedance Amplifier
Output Drive Current
50
A
Amplifier output voltage
Vout
1.5V; above
this output voltage,
maximum output
current drops off
I
CC
STOP Mode Current with
Transimpedance Amplifier
Active
10
A
No other peripherals
are enabled
Symbol
Parameter
V
DD
= 2.7 to 3.6V
T
A
= -40C to +105C
Units
Conditions
Minimum
Typical
Maximum
V
OS
Input DC Offset
5
mV
V
CREF
Programmable Internal
Reference Voltage Range
0
1.8
V
User-programmable
in 200mV step
V
CREF
Programmable Internal
Reference Voltage
0.92
1.0
1.08
V
Default
(CMP0[REFLVL]=5H)
T
PROP
Propagation Delay
100
ns
V
HYS
Input Hysteresis
4
mV
Table 124. Analog-to-Digital Converter Electrical Characteristics and Timing (Continued)
Symbol
Parameter
V
DD
= 2.7 to 3.6V
T
A
= -40C to +105C
Units
Conditions
Minimum
Typical
Maximum
1
Analog source impedance affects the ADC offset voltage (because of pin leakage) and input settling
time.
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
200
Table 126. Temperature Sensor Electrical Characteristics
General Purpose I/O Port Input Data Sample Timing
Figure 32 illustrates timing of the GPIO Port input sampling. The input value on a GPIO
Port pin is sampled on the rising edge of the system clock. The Port value is available to
the eZ8 CPU on the second rising clock edge following the change of the Port value.
Symbol
Parameter
V
DD
= 2.7 to 3.6V
T
A
= -40C to +105C
Units
Conditions
Minimum
Typical
Maximum
T
AERR
Temperature Error
7
+7
C
Over the range -40C
to +105C (as
measured by ADC)
T
AERR
Temperature Error
1.5
+1.5
C
Over the range +20C
to +30C (as
measured by ADC
T
AERR
Temperature Error
TBD
TBD
C
Over the range -40C
to +105C (as
measured by
comparator)
t
WAKE
Wakeup Time
80
100
us
Time required for
Temperature Sensor
to stabilize after
enabling
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
201
Figure 32. Port Input Sample Timing
Table 127. GPIO Port Input Timing
Parameter
Abbreviation
Delay (ns)
Minimum
Maximum
T
S_PORT
Port Input Transition to XIN Rise Setup Time
(Not pictured)
5
T
H_PORT
XIN Rise to Port Input Transition Hold Time
(Not pictured)
0
T
SMR
GPIO Port Pin Pulse Width to ensure STOP Mode
Recovery
(for GPIO Port Pins enabled as SMR sources)
1
s
System
TCLK
Port Pin
Port Value
Changes to 0
0 Latched
Into Port Input
Input Value
Port Input Data
Register Latch
Clock
Data Register
Port Input Data
Read on Data Bus
Port Input Data Register
Value 0 Read
by eZ8
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
202
General Purpose I/O Port Output Timing
Figure 33 and Table 128 provide timing information for GPIO Port pins.
Figure 33. GPIO Port Output Timing
Table 128. GPIO Port Output Timing
Parameter
Abbreviation
Delay (ns)
Minimum
Maximum
GPIO Port pins
T
1
XIN Rise to Port Output Valid Delay
15
T
2
XIN Rise to Port Output Hold Time
2
XIN
Port Output
TCLK
T1
T2
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
203
On-Chip Debugger Timing
Figure 34 and Table 129 provide timing information for the DBG pin. The DBG pin tim-
ing specifications assume a 4ns maximum rise and fall time.
Figure 34. On-Chip Debugger Timing
Table 129. On-Chip Debugger Timing
Parameter
Abbreviation
Delay (ns)
Minimum
Maximum
DBG
T
1
XIN Rise to DBG Valid Delay
15
T
2
XIN Rise to DBG Output Hold Time
2
T
3
DBG to XIN Rise Input Setup Time
5
T
4
DBG to XIN Rise Input Hold Time
5
XIN
DBG
TCLK
T1
T2
(Output)
DBG
T3
T4
(Input)
Output Data
Input Data
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
204
UART Timing
Figure 35 and Table 130 provide timing information for UART pins for the case where
CTS is used for flow control. The CTS to DE assertion delay (T1) assumes the transmit
data register has been loaded with data prior to CTS assertion.
Figure 35. UART Timing With CTS
Table 130. UART Timing With CTS
Parameter
Abbreviation
Delay (ns)
Minimum
Maximum
UART
T
1
CTS Fall to DE output delay
2 * XIN
period
2 * XIN period
+ 1 bit time
T
2
DE assertion to TXD falling edge (start bit) delay 5
T
3
End of Stop Bit(s) to DE deassertion delay
5
CTS
DE
T1
(Output)
TXD
T2
(Output)
(Input)
start
bit 0
bit 1
bit 7
parity
stop
end of
stop bit(s)
T3
PS024705-0405
P R E L I M I N A R Y Electrical
Characteristics
Z8 Encore! XP
F08xA Series
Product Specification
205
Figure 36 and Table 131 provide timing information for UART pins for the case where
CTS is not used for flow control. DE asserts after the transmit data register has been writ-
ten. DE remains asserted for multiple characters as long as the transmit data register is
written with the next character before the current character has completed.
Figure 36. UART Timing Without CTS
Table 131. UART Timing Without CTS
Parameter
Abbreviation
Delay (ns)
Minimum
Maximum
UART
T
1
DE assertion to TXD falling edge (start bit) delay
1 * XIN
period
1 bit time
T
2
End of Stop Bit(s) to DE deassertion delay (Tx
data register is empty)
5
DE
T1
(Output)
TXD
T2
(Output)
start
bit0
bit 1
bit 7
parity
stop
end of
stop bit(s)
PS024705-0405
P R E L I M I N A R Y Packaging
Z8 Encore! XP
F08xA Series
Product Specification
206
Packaging
Figure 37 illustrates the 20-pin Plastic Dual Inline Package (PDIP) available for the Z8
Encore! XP
TM
8K Series devices.
Figure 37.20-Pin Plastic Dual Inline Package (PDIP)
PS024705-0405
P R E L I M I N A R Y Packaging
Z8 Encore! XP
F08xA Series
Product Specification
207
Figure 38 illustrates the 20-pin Small Outline Integrated Circuit Package (SOIC) available
for the Z8 Encore! XP
TM
8K Series devices.
Figure 38.20-Pin Small Outline Integrated Circuit Package (SOIC)
PS024705-0405
P R E L I M I N A R Y Packaging
Z8 Encore! XP
F08xA Series
Product Specification
208
Figure 39 illustrates the 20-pin Small Shrink Outline Package (SSOP) available for the Z8
Encore! XP
TM
8K Series devices.
Figure 39.20-Pin Small Shrink Outline Package (SSOP)
PS024705-0405
P R E L I M I N A R Y Packaging
Z8 Encore! XP
F08xA Series
Product Specification
209
Figure 40 illustrates the 28-pin Plastic Dual Inline Package (PDIP) available for the Z8
Encore! XP
TM
8K Series devices.
Figure 40.28-Pin Plastic Dual Inline Package (PDIP)
PS024705-0405
P R E L I M I N A R Y Packaging
Z8 Encore! XP
F08xA Series
Product Specification
210
Figure 41 illustrates the 28-pin Small Outline Integrated Circuit package (SOIC) available
in the Z8 Encore! XP
TM
8K Series devices.
Figure 41.28-Pin Small Outline Integrated Circuit Package (SOIC)
PS024705-0405
P R E L I M I N A R Y Packaging
Z8 Encore! XP
F08xA Series
Product Specification
211
Figure 42 illustrates the 28-pin Small Shrink Outline Package (SSOP) available for the Z8
Encore! XP
TM
8K Series devices.
Figure 42.28-Pin Small Shrink Outline Package (SSOP)
SYMBOL
A
A1
B
C
A2
e
MILLIMETER
INCH
MIN
MAX
MIN
MAX
1.73
0.05
1.68
0.25
5.20
0.65 TYP
0.09
10.07
7.65
0.63
1.86
0.0256 TYP
0.13
10.20
1.73
7.80
5.30
1.99
0.21
1.78
0.75
0.068
0.002
0.066
0.010
0.205
0.004
0.397
0.301
0.025
0.073
0.005
0.068
0.209
0.006
0.402
0.307
0.030
0.078
0.008
0.070
0.015
0.212
0.008
0.407
0.311
0.037
0.38
0.20
10.33
5.38
7.90
0.95
NOM
NOM
D
E
H
L
CONTROLLING DIMENSIONS: MM
LEADS ARE COPLANAR WITHIN .004 INCHES.
H
C
DETAIL A
E
D
28
15
1
14
SEATING PLANE
A2
e
A
Q1
A1
B
L
0 - 8
PS024705-0405
P R E L I M I N A R Y Ordering
Information
Z8 Encore! XP
F08xA Series
Product Specification
212
Ordering Information
Part Num
b
er
Flas
h
RA
M
I/
O Li
nes
Interrupt
s
16-Bit T
i
mers
w/
PWM
10-Bit A/
D C
h
annels
UA
RT with IrDA
Comp
arator
T
e
mper
atu
r
e Sens
or
Desc
ription
Z8 Encore! XP
F08xA with 8KB Flash, 10-Bit Analog-to-Digital Converter
Standard Temperature: 0 to 70C
Z8F082ASH020SC
8KB
1KB
17
18
2 7 1 1 1 SOIC 20-pin package
Z8F082AHH020SC
8KB
1KB
17
18
2 7 1 1 1 SSOP 20-pin package
Z8F082APH020SC
8KB
1KB
17
18
2 7 1 1 1 PDIP 20-pin package
Z8F082ASJ020SC
8KB
1KB
23
18
2 8 1 1 1 SOIC 28-pin package
Z8F082AHJ020SC
8KB
1KB
23
18
2 8 1 1 1 SSOP 28-pin package
Z8F082APJ020SC
8KB
1KB
23
18
2 8 1 1 1 PDIP 28-pin package
Extended Temperature: -40 to 105C
Z8F082ASH020EC
8KB
1KB
17
18
2 7 1 1 1 SOIC 20-pin package
Z8F082AHH020EC
8KB
1KB
17
18
2 7 1 1 1 SSOP 20-pin package
Z8F082APH020EC
8KB
1KB
17
18
2 7 1 1 1 PDIP 20-pin package
Z8F082ASJ020EC
8KB
1KB
23
18
2 8 1 1 1 SOIC 28-pin package
Z8F082AHJ020EC
8KB
1KB
23
18
2 8 1 1 1 SSOP 28-pin package
Z8F082APJ020EC
8KB
1KB
23
18
2 8 1 1 1 PDIP 28-pin package
PS024705-0405
P R E L I M I N A R Y Ordering
Information
Z8 Encore! XP
F08xA Series
Product Specification
213
Z8 Encore! XP
F08xA with 8KB Flash
Standard Temperature: 0 to 70C
Z8F081ASH020SC
8KB
1KB
17
18
2 0 1 1 1 SOIC 20-pin package
Z8F081AHH020SC
8KB
1KB
17
18
2 0 1 1 1 SSOP 20-pin package
Z8F081APH020SC
8KB
1KB
17
18
2 0 1 1 1 PDIP 20-pin package
Z8F081ASJ020SC
8KB
1KB
25
18
2 0 1 1 1 SOIC 28-pin package
Z8F081AHJ020SC
8KB
1KB
25
18
2 0 1 1 1 SSOP 28-pin package
Z8F081APJ020SC
8KB
1KB
25
18
2 0 1 1 1 PDIP 28-pin package
Extended Temperature: -40 to 105C
Z8F081ASH020EC
8KB
1KB
17
18
2 0 1 1 1 SOIC 20-pin package
Z8F081AHH020EC
8KB
1KB
17
18
2 0 1 1 1 SSOP 20-pin package
Z8F081APH020EC
8KB
1KB
17
18
2 0 1 1 1 PDIP 20-pin package
Z8F081ASJ020EC
8KB
1KB
25
18
2 0 1 1 1 SOIC 28-pin package
Z8F081AHJ020EC
8KB
1KB
25
18
2 0 1 1 1 SSOP 28-pin package
Z8F081APJ020EC
8KB
1KB
25
18
2 0 1 1 1 PDIP 28-pin package
Z8F082A28100KIT
Development Kit
P
a
rt Number
Fla
s
h
RA
M
I/
O Li
ne
s
Int
e
r
r
upt
s
16-Bit T
i
mers
w/PWM
10-Bit A/D Channels
U
ART with IrDA
Co
mp
a
r
at
or
T
e
mp
era
t
ur
e Se
nso
r
De
scr
ip
tion
PS024705-0405
P R E L I M I N A R Y Ordering
Information
Z8 Encore! XP
F08xA Series
Product Specification
214
Part Number Suffix Designations
Z8 F 08 2A S
H 020 S
C
Environmental Flow:
C = Plastic Standard
Temperature Range (C):
S = Standard, 0 to 70
E = Extended, -40 to +105
Speed:
020 = 20MHz
Pin Count:
H = 20
J = 28
Package:
H = SSOP
P = PDIP
S = SOIC
Device Type
Memory Size:
08 = 8KB Flash, 1KB RAM
Memory Type:
F = Flash
Device Family
PS024705-0405
P R E L I M I N A R Y Ordering
Information
Z8 Encore! XP
F08xA Series
Product Specification
215
Precharacterization Product
The product represented by this document is newly introduced and ZiLOG has not com-
pleted the full characterization of the product. The document states what ZiLOG knows
about this product at this time, but additional features or nonconformance with some
aspects of the document might be found, either by ZiLOG or its customers in the course of
further application and characterization work. In addition, ZiLOG cautions that delivery
might be uncertain at times, because of start-up yield issues.
ZiLOG, Inc.
532 Race Street
San Jose, CA 95126
Telephone (408) 558-8500
FAX 408 558-8300
Internet:
www.zilog.com
Customer Support
For valuable information about downloading other relevant documents or for hardware
and software development tools, visit the ZiLOG web site at
www.zilog.com
.
PS024705-0405
P R E L I M I N A R Y Customer
Feedback
Form
Z8 Encore! XP
F08xA Series
Product Specification
216
Customer Feedback Form
Z8 Encore! XP
8K Series High Performance MCUs with Flash Memory and 10-Bit A/D
Converter Product Specification
If you experience any problems while operating this product, or if you note any inaccuracies while reading
this document, please copy and complete this form and mail it to the address below or go to
www.zilog.com
(see Return Information, below). We also welcome your suggestions!
Customer Information
Product Information
Return Information
ZiLOG
System Test/Customer Support
532 Race Street
San Jose, CA 95126-3432
www.zilog.com
Name
Country
Company
Phone
Address
Fax
City/State/Zip
Email
Serial # or Board Fab #/Rev. #
Software Version
Document Number
Host Computer Description/Type
PS024705-0405
P R E L I M I N A R Y Customer
Feedback
Form
Z8 Encore! XP
F08xA Series
Product Specification
217
Problem Description or Suggestion
Provide a complete description of the problem or your suggestion. If you are reporting a specific problem,
include all steps leading up to the occurrence of the problem. Attach additional pages as necessary.
Z8 Encore! XP
F08xA Series
Product Specification
PS024705-0405
P R E L I M I N A R Y Index
218
Index
Symbols
# 173
% 173
@ 173
Numerics
10-bit ADC 4
40-lead plastic dual-inline package 210, 211
A
absolute maximum ratings 191
AC characteristics 194
ADC 174
architecture 108
automatic power-down 109
block diagram 109
continuous conversion 111
control register 117, 119
control register definitions 117
data high byte register 120
data low bits register 120
electrical characteristics and timing 197
operation 109
single-shot conversion 110
ADCCTL register 117, 119
ADCDH register 120
ADCDL register 120
ADCX 174
ADD 174
add - extended addressing 174
add with carry 174
add with carry - extended addressing 174
additional symbols 173
address space 12
ADDX 174
analog signals 9
analog-to-digital converter (ADC) 108
AND 176
ANDX 176
arithmetic instructions 174
assembly language programming 170
assembly language syntax 171
B
B 173
b 172
baud rate generator, UART 94
BCLR 175
binary number suffix 173
BIT 175
bit 172
clear 175
manipulation instructions 175
set 175
set or clear 175
swap 175
test and jump 177
test and jump if non-zero 177
test and jump if zero 177
bit jump and test if non-zero 177
bit swap 177
block diagram 2
block transfer instructions 175
BRK 177
BSET 175
BSWAP 175, 177
BTJ 177
BTJNZ 177
BTJZ 177
C
CALL procedure 177
capture mode 76, 77
capture/compare mode 76
cc 172
CCF 175
characteristics, electrical 191
clear 176
CLR 176
COM 176
Z8 Encore! XP
F08xA Series
Product Specification
PS024705-0405
P R E L I M I N A R Y Index
219
compare 76
compare - extended addressing 174
compare mode 76
compare with carry 174
compare with carry - extended addressing 174
complement 176
complement carry flag 175
condition code 172
continuous conversion (ADC) 111
continuous mode 76
control register definition, UART 95
Control Registers 12, 15
counter modes 76
CP 174
CPC 174
CPCX 174
CPU and peripheral overview 4
CPU control instructions 175
CPX 174
Customer Feedback Form 216
Customer Information 216
D
DA 172, 174
data memory 13
DC characteristics 192
debugger, on-chip 148
DEC 174
decimal adjust 174
decrement 174
decrement and jump non-zero 177
decrement word 174
DECW 174
destination operand 173
device, port availability 31
DI 175
direct address 172
disable interrupts 175
DJNZ 177
dst 173
E
EI 175
electrical characteristics 191
ADC 197
flash memory and timing 196
GPIO input data sample timing 200
watch-dog timer 196, 199
enable interrupt 175
ER 172
extended addressing register 172
external pin reset 23
eZ8 CPU features 4
eZ8 CPU instruction classes 173
eZ8 CPU instruction notation 171
eZ8 CPU instruction set 170
eZ8 CPU instruction summary 178
F
FCTL register 134, 140
features, Z8 Encore! 1
first opcode map 189
FLAGS 173
flags register 173
flash
controller 4
option bit address space 140
option bit configuration - reset 138
program memory address 0000H 141
program memory address 0001H 142
flash memory 126
arrrangement 127
byte programming 132
code protection 130
configurations 126
control register definitions 134, 140
controller bypass 133
electrical characteristics and timing 196
flash control register 134, 140
flash option bits 131
flash status register 134
flow chart 129
frequency high and low byte registers 136
mass erase 132
Z8 Encore! XP
F08xA Series
Product Specification
PS024705-0405
P R E L I M I N A R Y Index
220
operation 128
operation timing 130
page erase 132
page select register 135, 136
FPS register 135, 136
FSTAT register 134
G
gated mode 76
general-purpose I/O 31
GPIO 4, 31
alternate functions 32
architecture 31
control register definitions 37
input data sample timing 200
interrupts 36
port A-C pull-up enable sub-registers 41,
42
port A-H address registers 37
port A-H alternate function sub-registers 39
port A-H control registers 38
port A-H data direction sub-registers 38
port A-H high drive enable sub-registers 40
port A-H input data registers 43
port A-H output control sub-registers 40
port A-H output data registers 43, 44
port A-H stop mode recovery sub-registers
41
port availability by device 31
port input timing 201
port output timing 202
H
H 173
HALT 175
halt mode 29, 175
hexadecimal number prefix/suffix 173
I
I2C 4
IM 172
immediate data 172
immediate operand prefix 173
INC 174
increment 174
increment word 174
INCW 174
indexed 172
indirect address prefix 173
indirect register 172
indirect register pair 172
indirect working register 172
indirect working register pair 172
infrared encoder/decoder (IrDA) 104
Instruction Set 170
instruction set, ez8 CPU 170
instructions
ADC 174
ADCX 174
ADD 174
ADDX 174
AND 176
ANDX 176
arithmetic 174
BCLR 175
BIT 175
bit manipulation 175
block transfer 175
BRK 177
BSET 175
BSWAP 175, 177
BTJ 177
BTJNZ 177
BTJZ 177
CALL 177
CCF 175
CLR 176
COM 176
CP 174
CPC 174
CPCX 174
CPU control 175
CPX 174
DA 174
DEC 174
Z8 Encore! XP
F08xA Series
Product Specification
PS024705-0405
P R E L I M I N A R Y Index
221
DECW 174
DI 175
DJNZ 177
EI 175
HALT 175
INC 174
INCW 174
IRET 177
JP 177
LD 176
LDC 176
LDCI 175, 176
LDE 176
LDEI 175
LDX 176
LEA 176
load 176
logical 176
MULT 174
NOP 175
OR 176
ORX 176
POP 176
POPX 176
program control 177
PUSH 176
PUSHX 176
RCF 175
RET 177
RL 177
RLC 177
rotate and shift 177
RR 177
RRC 177
SBC 174
SCF 175
SRA 177
SRL 178
SRP 175
STOP 176
SUB 174
SUBX 174
SWAP 178
TCM 175
TCMX 175
TM 175
TMX 175
TRAP 177
watch-dog timer refresh 176
XOR 177
XORX 177
instructions, eZ8 classes of 173
interrupt control register 57
interrupt controller 46
architecture 46
interrupt assertion types 49
interrupt vectors and priority 49
operation 48
register definitions 50
software interrupt assertion 50
interrupt edge select register 56
interrupt request 0 register 50
interrupt request 1 register 51
interrupt request 2 register 52
interrupt return 177
interrupt vector listing 46
interrupts
UART 92
IR 172
Ir 172
IrDA
architecture 104
block diagram 104
control register definitions 107
operation 104
receiving data 106
transmitting data 105
IRET 177
IRQ0 enable high and low bit registers 53
IRQ1 enable high and low bit registers 54
IRQ2 enable high and low bit registers 55
IRR 172
Irr 172
J
JP 177
jump, conditional, relative, and relative condi-
Z8 Encore! XP
F08xA Series
Product Specification
PS024705-0405
P R E L I M I N A R Y Index
222
tional 177
L
LD 176
LDC 176
LDCI 175, 176
LDE 176
LDEI 175, 176
LDX 176
LEA 176
load 176
load constant 175
load constant to/from program memory 176
load constant with auto-increment addresses
176
load effective address 176
load external data 176
load external data to/from data memory and
auto-increment addresses 175
load external to/from data memory and auto-in-
crement addresses 176
load instructions 176
load using extended addressing 176
logical AND 176
logical AND/extended addressing 176
logical exclusive OR 177
logical exclusive OR/extended addressing 177
logical instructions 176
logical OR 176
logical OR/extended addressing 176
low power modes 28
M
master interrupt enable 48
memory
data 13
program 13
mode
capture 76, 77
capture/compare 76
continuous 76
counter 76
gated 76
one-shot 75
PWM 76
modes 76
MULT 174
multiply 174
multiprocessor mode, UART 90
N
NOP (no operation) 175
notation
b 172
cc 172
DA 172
ER 172
IM 172
IR 172
Ir 172
IRR 172
Irr 172
p 172
R 172
r 172
RA 172
RR 172
rr 172
vector 172
X 172
notational shorthand 172
O
OCD
architecture 148
auto-baud detector/generator 151
baud rate limits 151
block diagram 148
breakpoints 152
commands 153
control register 158
data format 151
DBG pin to RS-232 Interface 149
debug mode 150
Z8 Encore! XP
F08xA Series
Product Specification
PS024705-0405
P R E L I M I N A R Y Index
223
debugger break 177
interface 149
serial errors 152
status register 159
timing 203
OCD commands
execute instruction (12H) 157
read data memory (0DH) 156
read OCD control register (05H) 155
read OCD revision (00H) 154
read OCD status register (02H) 154
read program counter (07H) 155
read program memory (0BH) 156
read program memory CRC (0EH) 157
read register (09H) 155
read runtime counter (03H) 154
step instruction (10H) 157
stuff instruction (11H) 157
write data memory (0CH) 156
write OCD control register (04H) 154
write program counter (06H) 155
write program memory (0AH) 156
write register (08H) 155
on-chip debugger (OCD) 148
on-chip debugger signals 10
on-chip oscillator 165
one-shot mode 75
opcode map
abbreviations 188
cell description 187
first 189
second after 1FH 190
Operational Description 19, 28, 31, 46, 58, 79,
84, 104, 108, 122, 124, 126, 138, 148, 160,
165, 169
OR 176
ordering information 212
ORX 176
oscillator signals 10
P
p 172
packaging
20-pin PDIP 206, 207
20-pin SSOP 208, 211
28-pin PDIP 209
28-pin SOIC 210
PDIP 210, 211
part selection guide 2
PC 173
PDIP 210, 211
peripheral AC and DC electrical characteristics
195
pin characteristics 11
Pin Descriptions 7
polarity 172
POP 176
pop using extended addressing 176
POPX 176
port availability, device 31
port input timing (GPIO) 201
port output timing, GPIO 202
power supply signals 10
power-down, automatic (ADC) 109
power-on and voltage brown-out electrical
characteristics and timing 195
power-on reset (POR) 21
Problem Description or Suggestion 217
Product Information 216
program control instructions 177
program counter 173
program memory 13
PUSH 176
push using extended addressing 176
PUSHX 176
PWM mode 76
PxADDR register 37
PxCTL register 38
R
R 172
r 172
RA
register address 172
RCF 175
receive
Z8 Encore! XP
F08xA Series
Product Specification
PS024705-0405
P R E L I M I N A R Y Index
224
IrDA data 106
receiving UART data-interrupt-driven method
89
receiving UART data-polled method 88
register 172
ADC control (ADCCTL) 117, 119
ADC data high byte (ADCDH) 120
ADC data low bits (ADCDL) 120
flash control (FCTL) 134, 140
flash high and low byte (FFREQH and
FREEQL) 136
flash page select (FPS) 135, 136
flash status (FSTAT) 134
GPIO port A-H address (PxADDR) 37
GPIO port A-H alternate function sub-regis-
ters 39
GPIO port A-H control address (PxCTL) 38
GPIO port A-H data direction sub-registers
39
OCD control 158
OCD status 159
UARTx baud rate high byte (UxBRH) 101
UARTx baud rate low byte (UxBRL) 101
UARTx Control 0 (UxCTL0) 98, 101
UARTx control 1 (UxCTL1) 99
UARTx receive data (UxRXD) 96
UARTx status 0 (UxSTAT0) 96
UARTx status 1 (UxSTAT1) 97
UARTx transmit data (UxTXD) 95
watch-dog timer control (WDTCTL) 26, 82,
123, 163
watch-dog timer reload high byte (WDTH)
83
watch-dog timer reload low byte (WDTL)
83
watch-dog timer reload upper byte (WDTU)
83
register file 12
register pair 172
register pointer 173
reset
and stop mode characteristics 19
and stop mode recovery 19
carry flag 175
sources 20
RET 177
return 177
Return Information 216
RL 177
RLC 177
rotate and shift instuctions 177
rotate left 177
rotate left through carry 177
rotate right 177
rotate right through carry 177
RP 173
RR 172, 177
rr 172
RRC 177
S
SBC 174
SCF 175
second opcode map after 1FH 190
set carry flag 175
set register pointer 175
shift right arithmatic 177
shift right logical 178
signal descriptions 8
single-sho conversion (ADC) 110
software trap 177
source operand 173
SP 173
SRA 177
src 173
SRL 178
SRP 175
stack pointer 173
STOP 176
stop mode 28, 176
stop mode recovery
sources 24
using a GPIO port pin transition 25, 26
using watch-dog timer time-out 25
SUB 174
subtract 174
subtract - extended addressing 174
Z8 Encore! XP
F08xA Series
Product Specification
PS024705-0405
P R E L I M I N A R Y Index
225
subtract with carry 174
subtract with carry - extended addressing 174
SUBX 174
SWAP 178
swap nibbles 178
symbols, additional 173
T
TCM 175
TCMX 175
test complement under mask 175
test complement under mask - extended ad-
dressing 175
test under mask 175
test under mask - extended addressing 175
timer signals 9
timers 58
architecture 58
block diagram 59
capture mode 66, 67, 76, 77
capture/compare mode 70, 76
compare mode 68, 76
continuous mode 60, 76
counter mode 61, 62
counter modes 76
gated mode 69, 76
one-shot mode 59, 75
operating mode 59
PWM mode 63, 64, 76
reading the timer count values 71
reload high and low byte registers 72
timer control register definitions 72
timer output signal operation 71
timers 0-3
control registers 74, 75
high and low byte registers 72, 73
TM 175
TMX 175
tools, hardware and software 215
transmit
IrDA data 105
transmitting UART data-polled method 86
transmitting UART dat-interrupt-driven method
87
TRAP 177
U
UART 4
architecture 84
baud rate generator 94
baud rates table 102
control register definitions 95
controller signals 9
data format 85
interrupts 92
multiprocessor mode 90
receiving data using interrupt-driven meth-
od 89
receiving data using the polled method 88
transmitting data usin the interrupt-driven
method 87
transmitting data using the polled method
86
x baud rate high and low registers 101
x control 0 and control 1 registers 98
x status 0 and status 1 registers 96, 97
UxBRH register 101
UxBRL register 101
UxCTL0 register 98, 101
UxCTL1 register 99
UxRXD register 96
UxSTAT0 register 96
UxSTAT1 register 97
UxTXD register 95
V
vector 172
voltage brown-out reset (VBR) 22
W
watch-dog timer
approximate time-out delay 80
approximate time-out delays 79, 122, 124,
160, 169
Z8 Encore! XP
F08xA Series
Product Specification
PS024705-0405
P R E L I M I N A R Y Index
226
CNTL 22
control register 82, 123, 163
electrical characteristics and timing 196,
199
interrupt in noromal operation 80
interrupt in stop mode 81
operation 79, 122, 124, 160, 169
refresh 80, 176
reload unlock sequence 81
reload upper, high and low registers 82
reset 23
reset in normal operation 81
reset in Stop mode 81
time-out response 80
WDTCTL register 26, 82, 123, 163
WDTH register 83
WDTL register 83
working register 172
working register pair 172
WTDU register 83
X
X 172
XOR 177
XORX 177
Z
Z8 Encore!
block diagram 2
features 1
part selection guide 2