INA159 - Precision, Gain Of 0.2 Level Translation Difference Amplifier
INA159AIDGKR - Precision, Gain of 0.2 Level Translation DIFFERENCE AMPLIFIER
INA159AIDGKRG4 - High-Speed, Precision Gain of 0.2 Level Translation Difference Amplifier The INA159 isA high slew rate, G = 1/5 difference amplifier consisting ofA precision op amp withA precision resistor network. The gain of 1/5 makes the INA159 useful to couple ±10V signals to single-supply analog-to-digital converters (ADCs), particularly those operating onA single +5V supply. The on-chip resistors are laser-trimmed for accurate gain and high common-mode rejection. Excellent temperature coefficient of resistance (T
INA159AIDGKT - Precision, Gain of 0.2 Level Translation DIFFERENCE AMPLIFIER
INA159AIDGKTG4 - Precision, Gain of 0.2 Level Translation DIFFERENCE AMPLIFIER
INA168NA/250 - INA168, High-side Measurement Current Shunt Monitor
INA168NA/3K - INA168, High-side Measurement Current Shunt Monitor
INA169 - High-Side Measurement CURRENT SHUNT MONITOR
INA169NA/250 - INA169, High-side Measurement Current Shunt Monitor
INA169NA/3K - INA169, High-side Measurement Current Shunt Monitor
INA169-Q1 - HIGH SIDE MEASUREMENT CURRENT SHUNT MONITOR
INA169QPWRQ1 - HIGH SIDE MEASUREMENT CURRENT SHUNT MONITOR
INA193AIDBVRG4 - Voltage Output High-Side Measurement Current Shunt MonitorThe INA193—INA198 family of current shunt monitors with voltage output can sense drops across shunts at common-mode voltages from –16V to +80V, independent of the INA19x supply voltage. They are available with three output voltage scales: 20V/V, 50V/V, and 100V/V. The 500kHz bandwidth simplifies use in current control loops. The INA193—INA195 provide identical functions but alternative pin configurations to the INA196—INA198 (respectively).The INA193
INA193AIDBVTG4 - Voltage Output High-Side Measurement Current Shunt MonitorThe INA193—INA198 family of current shunt monitors with voltage output can sense drops across shunts at common-mode voltages from –16V to +80V, independent of the INA19x supply voltage. They are available with three output voltage scales: 20V/V, 50V/V, and 100V/V. The 500kHz bandwidth simplifies use in current control loops. The INA193—INA195 provide identical functions but alternative pin configurations to the INA196—INA198 (respectively).The INA193
INA206 - High-Side Measurement Current-Shunt Monitor with Dual Comparators
INA206A - High-Side Measurement Current-Shunt Monitor with Dual Comparators
INA206AID - The INA206, INA207, and INA208 areA family of high-side, current-shunt monitors with voltage output, dual comparators, and voltage reference. The INA206, INA207, and INA208 can sense drops across shunts at common-mode voltages from -16V to +80V. The INA206, INA207, and INA208 are available with three output voltage scales: 20V/V, 50V/V, and 100V/V, with up to 500kHz bandwidth.The INA206, INA207, and INA208 also incorporate two open-drain comparators with internal 0.6V references. On 14-pin versions, the co
INA206AIDG4 - The INA206, INA207, and INA208 areA family of high-side, current-shunt monitors with voltage output, dual comparators, and voltage reference. The INA206, INA207, and INA208 can sense drops across shunts at common-mode voltages from -16V to +80V. The INA206, INA207, and INA208 are available with three output voltage scales: 20V/V, 50V/V, and 100V/V, with up to 500kHz bandwidth.The INA206, INA207, and INA208 also incorporate two open-drain comparators with internal 0.6V references. On 14-pin versions, the co
INA206AIDR - The INA206, INA207, and INA208 areA family of high-side, current-shunt monitors with voltage output, dual comparators, and voltage reference. The INA206, INA207, and INA208 can sense drops across shunts at common-mode voltages from -16V to +80V. The INA206, INA207, and INA208 are available with three output voltage scales: 20V/V, 50V/V, and 100V/V, with up to 500kHz bandwidth.The INA206, INA207, and INA208 also incorporate two open-drain comparators with internal 0.6V references. On 14-pin versions, the co
INA206AIDRG4 - The INA206, INA207, and INA208 areA family of high-side, current-shunt monitors with voltage output, dual comparators, and voltage reference. The INA206, INA207, and INA208 can sense drops across shunts at common-mode voltages from -16V to +80V. The INA206, INA207, and INA208 are available with three output voltage scales: 20V/V, 50V/V, and 100V/V, with up to 500kHz bandwidth.The INA206, INA207, and INA208 also incorporate two open-drain comparators with internal 0.6V references. On 14-pin versions, the co
INA207 - High-Side Measurement Current-Shunt Monitor with Dual Comparators
INA208 - High-Side Measurement Current-Shunt Monitor with Dual Comparators
INA2126E/250 - INA2126, Micropower Instrumentation Amplifier Single and Dual Versions
INA2126E/2K5 - INA2126, Micropower Instrumentation Amplifier Single and Dual Versions
INA2126EA/250 - INA2126, Micropower Instrumentation Amplifier Single and Dual Versions
INA2126EA/2K5 - INA2126, Micropower Instrumentation Amplifier Single and Dual Versions
INA2126U/2K5 - INA2126, Micropower Instrumentation Amplifier Single and Dual Versions
INA2126UA/2K5 - INA2126, Micropower Instrumentation Amplifier Single and Dual Versions
INA2128U/1K - INA2128, Dual, Low Power Instrumentation Amplifier
INA2128UA/1K - INA2128, Dual, Low Power Instrumentation Amplifier