ChipFind - документация

Электронный компонент: 358RP

Скачать:  PDF   ZIP
1
Memory
All data sheets are subject to change without notice
(858) 503-3000 - Fax: (858) 503-3301 - www.maxwell.com
8-Channel Fault-Protected
358
2001 Maxwell Technologies
All rights reserved.
Analog Multiplexer
12.20.01 Rev 2
1000544
F
EATURES
:
R
AD
-P
AK
technology-hardened against natural space radi-
ation
Total dose hardness:
- > 50 krad (Si), depending upon space mission
Excellent Single Event Effect
- SEL
TH
> 80 MeV/mg/cm
2
- SEU
TH
> 80 MeV/mg/cm
2
Package:
- 16 pin R
AD
-P
AK
Flat Pack
All switches off with power supplies off
On channel turns OFF if overvoltage occurs
Only nanoamperes of input current under all fault condi-
tions
Operates from 4.5 to 18V supplies
All digital inputs are TTL and CMOS compatible
Significantly reduced power consumption
D
ESCRIPTION
:
Maxwells's 358 8-Channel single-ended (1 of 8) multiplexers
with fault protection features a greater than 50 krad (Si) total
dose tolerance, depending upon space mission. Using a
series N-channel, P-channel, N-channel structure, these multi-
plexers provide significantly improved fault protection. If the
power supplies to the fault-protected multiplexer are inadvert-
ently turned off while input voltages are still applied, all chan-
nels in the multiplexer are turned off, and only a few
nanoamperes of leakage current will flow into the inputs. This
protects not only the multiplexer and the circuitry driven by the
multiplexer, but also protects the sensors or signal sources
which drive the multiplexer. All digital inputs have logic thresh-
olds of 0.8V and 2.4V, ensuring both TTL and CMOS compati-
bility without requiring pullup resistors. Break-before-make
operation is guaranteed. Power supply currents have been
reduced and typical power dissipation is less than 2 mW.
Maxwell Technologies' patented R
AD
-P
AK
packaging technol-
ogy incorporates radiation shielding in the microcircuit pack-
age. It eliminates the need for box shielding while providing
the required radiation shielding for a lifetime in orbit or a space
mission. In a GEO orbit, Rad-Pak provides true greater than
50 krad (Si) total radiation dose tolerance, dependent upon
space mission. This product is available with packaging and
screening up to Class S.
Logic Diagram
Memory
2
All data sheets are subject to change without notice
2001 Maxwell Technologies
All rights reserved.
8-Channel Fault-Protected Analog Multiplexer
358
12.20.01 Rev 2
1000544
T
ABLE
1. P
INOUT
D
ESCRIPTION
P
IN
S
YMBOL
D
ESCRIPTION
1, 16, 15
A0-A2
Address Inputs
2
Enable
Enable Inputs
3
-V Supply
Negative Supply Voltage
4-7, 12-9
IN1-IN8
Analog Inputs-bidirectional
8
OUT
Output-bidirectional
13
+V Supply Positive Supply Voltage
14
GND
Ground
T
ABLE
2. 358 A
BSOLUTE
M
AXIMUM
R
ATINGS
Parameter
Symbol
Typ
Units
Voltage between Supply Pins
V+
V-
+44
+22
-22
V
Digital Input Overvoltage
VEN, VA Vsupply (+)
Vsupply (-)
+4
-4
V
Analog Input Overvoltage with Multiplexer
Power On:
VS Vsupply (+)
Vsupply (-)
+20
-20
V
Analog Input Overvoltage with Multiplexer
Power Off:
VS Vsupply (+)
Vsupply (-)
+35
-35
V
Continuous Current
Peak Current
(Pulse at 1 ms, 10% duty cycle max)
20
40
mA
Thermal Impedance
JC
2.69
C/W
Operating Temperature Range:
T
A
-55 to +125
C
Storage Temperature Range:
T
S
-65 to +150
C
T
ABLE
3. 358 E
LECTRICAL
C
HARACTERISTICS
(V
+
= 15V, V
-
= -15V, V
AH
= 2.4V, V
AL
= 0.8V, T
A
= -55
TO
+125C,
UNLESS
OTHERWISE
SPECIFIED
)
P
ARAMETER
T
EST
C
ONDITIONS
S
YMBOL
T
EMP
M
IN
T
YP
M
AX
U
NITS
STATIC
ON Resistance
V
D
= 10V, I
S
= 100A
V
AL
= 0.8V, V
AH
= 2.4V
r
DS(ON)
+25C
Full
1.2
1.5
1.5
1.8
k
Memory
3
All data sheets are subject to change without notice
2001 Maxwell Technologies
All rights reserved.
8-Channel Fault-Protected Analog Multiplexer
358
12.20.01 Rev 2
1000544
OFF Input Leakage Current
V
S
= 10V, V
D
= +10V
V
EN
= 0.8V
I
S(OFF)
+25C
Full
0.03
50
nA
OFF Output Leakage Current
V
D
= 10V, V
S
= +10V
V
EN
= 0.8V
I
D(OFF)
+25C
Full
0.1
200
nA
ON Channel Leakage Current
V
S(ALL)
= V
D
= 10V
1
V
AH
= V
EN
= 2.4V
V
AL
= 0.8V
I
D(ON)
+25C
Full
0.1
200
2
nA
Analog Signal Range
2
V
AN
Full
-15
15
V
FAULT
Output Leakage Current (with
Overvoltage)
V
D
= 0V
1
Analog Overvoltage = 33V
I
D(OFF)
+25C
Full
4.0
2.0
nA
A
Input Leakage Current (with Over-
voltage)
V
IN
= 25V, V
O
= 10V
1
I
S(OFF)
+25C
5.0
A
Input Leakage Current (w/ Power
Supplies Off)
V
IN
= 25V, V
EN
= V
O
= 0V
A
O
= A
1
= A
2
= OV or 5V
I
S(OFF)
+25C
2.0
A
INPUT
Input Low Threshold
V
AL
Full
0.8
V
Input High Threshold
V
AH
Full
2.4
V
Input Leakage Current (High or
Low)
V
A
= 4V or 0V
3
I
A
Full
1.0
A
DYNAMIC
Access Time
t
A
+25C
0.5
1.0
s
Break-Before-Make Delay
V
EN
= 5V, V
IN
= 10V
A
O
, A
1
, A
2
Strobed
t
on-
t
off
+25C
25
80
ns
Enable Delay (ON)
t
on(EN)
+25C
Full
300
500
1000
ns
Enable Delay (OFF)
t
off(EN)
+25C
Full
300
500
1000
ns
Setting Time: (0.1%)
(0.01%)
t
sett
+25C
1.2
3.5
s
"OFF Isolation"
4
V
EN
= 0.8V, R
L
= 1k
C
L
= 15pF, V = 7V
RMS
f = 100kHz
+25C
50
68
db
Channel Input Capacitance
C
S(OFF)
+25C
5
pF
Channel Output Capacitance
C
D(OFF)
+25C
25
pF
Digital Input Capacitance
C
A
+25C
5
pF
Digital Output Capacitance
C
DS(OFF)
+25C
0.1
pF
SUPPLY
T
ABLE
3. 358 E
LECTRICAL
C
HARACTERISTICS
(V
+
= 15V, V
-
= -15V, V
AH
= 2.4V, V
AL
= 0.8V, T
A
= -55
TO
+125C,
UNLESS
OTHERWISE
SPECIFIED
)
P
ARAMETER
T
EST
C
ONDITIONS
S
YMBOL
T
EMP
M
IN
T
YP
M
AX
U
NITS
Memory
4
All data sheets are subject to change without notice
2001 Maxwell Technologies
All rights reserved.
8-Channel Fault-Protected Analog Multiplexer
358
12.20.01 Rev 2
1000544
F
IGURE
1. I
NPUT
L
EAKAGE
VS
. I
NPUT
V
OLTAGE
WITH
V+ = V- = 0V
Positive Supply Current
V
EN
= 0.8V or 2.4V
V
A
= 0V or 5V
I+
+25C
Full
0.1
0.3
0.6
0.7
mA
Negative Supply Current
V
EN
= 0.8V or 2.4V
V
A
= 0V or 5V
I-
+25C
Full
0.01
0.02
0.1
0.2
mA
Power Supply Range for Continu-
ous Operation
5
V
OP
+25C
4.5
18
V
1. The value shown is the steady state value. The transient leakage is typically 10 A.
2. When the analog signal exceeds +13.5V or -12V the blocking action of the gate structure goes into operation. Only leakage
currents flow and the channel on resistance rises to infinity.
3. Digital input leakage is primarily due to the clamp diodes. Typical leakage is less than 1 nA @ +25C.
4. Guaranteed by design.
5. Electrical characteristics, such as ON Resistance, will change when power supplies other than 15V are used.
T
ABLE
3. 358 E
LECTRICAL
C
HARACTERISTICS
(V
+
= 15V, V
-
= -15V, V
AH
= 2.4V, V
AL
= 0.8V, T
A
= -55
TO
+125C,
UNLESS
OTHERWISE
SPECIFIED
)
P
ARAMETER
T
EST
C
ONDITIONS
S
YMBOL
T
EMP
M
IN
T
YP
M
AX
U
NITS
Memory
5
All data sheets are subject to change without notice
2001 Maxwell Technologies
All rights reserved.
8-Channel Fault-Protected Analog Multiplexer
358
12.20.01 Rev 2
1000544
F
IGURE
2. O
FF
C
HANNEL
L
EAKAGE
C
URRENT
VS
. I
NPUT
V
OLTAGE
WITH
15V S
UPPLIES
F
IGURE
3. O
UTPUT
L
EAKAGE
VS
. O
FF
C
HANNEL
O
VERVOLTAGE
WITH
15V S
UPPLIES
F
IGURE
4. R
DS(ON)
VS
. I
NPUT
V
OLTAGE
Memory
6
All data sheets are subject to change without notice
2001 Maxwell Technologies
All rights reserved.
8-Channel Fault-Protected Analog Multiplexer
358
12.20.01 Rev 2
1000544
Logic "0" = VAL < 0.8V, Logic "1" = VAH > 2.4V
TRUTH TABLE
A2
A1
A0
EN
ON SWITCH
X
X
X
0
NONE
0
0
0
1
1
0
0
1
1
2
0
1
0
1
3
0
1
1
1
4
1
0
0
1
5
1
0
1
1
6
1
1
0
1
7
1
1
1
1
8
Memory
7
All data sheets are subject to change without notice
2001 Maxwell Technologies
All rights reserved.
8-Channel Fault-Protected Analog Multiplexer
358
12.20.01 Rev 2
1000544
F16-01
All dimensions in inches
16-P
IN
R
AD
-P
AK
Q
UAD
F
LAT
P
ACKAGE
S
YMBOL
D
IMENSIONS
M
IN
N
OM
M
AX
A
.117
.130
.143
b
.015
.017
.022
c
.004
.005
.009
D
--
.415
.440
E
.245
.280
.285
E1
--
--
.315
E2
.130
.156
--
E3
.030
.062
--
e
.050 BSC
L
.325
.335
.345
Q
.020
.033
.045
S1
.005
.024
--
N
16
Memory
8
All data sheets are subject to change without notice
2001 Maxwell Technologies
All rights reserved.
8-Channel Fault-Protected Analog Multiplexer
358
12.20.01 Rev 2
1000544
Important Notice:
These data sheets are created using the chip manufacturer's published specifications. Maxwell Technologies verifies
functionality by testing key parameters either by 100% testing, sample testing or characterization.
The specifications presented within these data sheets represent the latest and most accurate information available to
date. However, these specifications are subject to change without notice and Maxwell Technologies assumes no
responsibility for the use of this information.
Maxwell Technologies' products are not authorized for use as critical components in life support devices or systems
without express written approval from Maxwell Technologies.
Any claim against Maxwell Technologies must be made within 90 days from the date of shipment from Maxwell Tech-
nologies. Maxwell Technologies' liability shall be limited to replacement of defective parts.
Memory
9
All data sheets are subject to change without notice
2001 Maxwell Technologies
All rights reserved.
8-Channel Fault-Protected Analog Multiplexer
358
12.20.01 Rev 2
1000544
Product Ordering Options
Model Number
Feature
Option Details
358
RP
F
X
Screening Flow
Package
Radiation Feature
Base Product
Nomenclature
Monolithic
S = Maxwell Class S
B = Maxwell Class B
E = Engineering (testing @ +25C)
I = Industrial (testing @ -55C,
+25C, +125C)
F = Flat Pack
RP = R
AD
-P
AK
package
8-Channel Fault-Protected Ana-
log Multiplexer